AC Load Bank

JUNXY ENERGY is manufacture of battery testing equipments, AC load banks. Get electrical backup power system as battery/UPS/generator/transformer etc.<br>

Télécharger la présentation

AC Load Bank

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com Operation Instructions On JUNXY-AC230V-10KW-R AC Load Bank It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, working in good condition if switched to be loaded when the main maintenance procedure Downtime could be maintenance and thorough inspections which are the key to power supply systems maintenance. Critical power backup equipment System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. So validating the condition and output of such power systems must inverter etc power or stop abnormally. reduced by supply in regular like UPS be conducted comprehensively. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything. Purely resistive load bank is the most common type of load bank, and it proves equivalent loading of both generator and prime mover. That is, for each kilowatt of load applied to the generator by the load bank, an equal amount of electrical energy converts to heat by power resistors, in a general way, this heat must be dissipated from the load bank by air forced means or other convection. The Junxy's resistors are made by high quality finned tubular heating elements, they are of the type where the surface area is enlarged by a strip in order to heat gases. At high power the surface temperature is small and the heating element is short. Meanwhile, Load elements are cooled usually via Fan Forced Air, blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test. Technical Specifications Model JUNXY-AC230V-10KW-R Sheathed alloy resistors and external heatsink Load Element Rated Voltage 230V 50HZ, single phase

  2. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com Rated Power 10KW Load Steps 4 Push Buttons: 1KW, 2KW, 2KW, 5KW Load Buttons to be pushed on 1KW Push on “1KW” 2KW Push on ONE of two “2KW” 3KW Push on “1KW” and ONE of two “2KW” 4KW Push on TWO “2KW” Load Power Adjustment Push on “5KW” Through Manual Control By 5KW Push Buttons Or push on “1KW” and “2KW” (RED lights on indicate 6KW Push on “1KW” and “5KW” loading status ) 7KW Push on ONE of two “2KW” and “5KW” 8KW Push on “1KW”, ONE of two “2KW” and “5KW” 9KW Push on TWO “2KW” and “5KW” 10KW Push on ALL load steps Power Factor PF=1.0 Load Accuracy ±5% Digital Meter Voltage, current, power, frequency and etc. Power Supply AC230V(±10%) 50HZ, single phase Load Cables Connection Back panel: L & N Insulation Class F Protection Level IP20(indoor use) Fan Noise 75dB Cooling Mode Force-air cooling

  3. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com Work Mode Continuous work Overheating/Buzzer alarm, Overheating/Overcurrent protection, Protections Dimension 483*600*355.6mm(W*L*H) Weight ≈35KG Ambient Temperature -10℃~+50℃ Mobility Three carrying handles and four wheels Humidity ≤95% Altitude ≤2500 meters Please follow the inspection instructions once the load bank is delivered to you before power on load bank to use. 1. General Inspection Normally JUNXY load bank is packed with wooden case for protection, please gently split the wooden case. Look to the load bank appearance, to see if any load bank case deformation, wet components, components & screws loose, and components disconnection, please take actions accordingly if any failed parts were found. Inspect all the accessories compared with our packing list, all parts include: Main unit-1set Power cord-1pcs Quick connectors for load cables-1pair(one red and one black) Load cables-1pair(one red and one black) User manual-1pcs Circuit diagram-1pcs 1 2 3 4 5 6 2. Control Panel Description Fan Power controlling the power and fan on/off. Green light ON indicates power on and fan working status Push Buttons Push on/off the 4 load steps to have load power from 1KW to 10KW. Red lights ON indicate working status. 1 2

  4. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com Please refer to above form for load adjustment. Temp Alarm Buzzer Alarming and shining when over temperature. Digital Meter Displaying voltage, current, power, frequency and etc. 3 4 3. Load Cables Connection: Plug in the power cord to load bank power socket while keep Fan Power Pushed Off. Make sure all EUT (equipment under test) is POWER OFF before load cables connection. Connect RED load cable to the load bank phase “L” with RED quick connector , and then the other end to EUT phase wire. Connect the BLACK load cable to the load bank phase “N” with BLACK quick connector , and then the other end to EUT. Check again to make sure all load cables connection reliable. 1 2 3 4 5 4. Load Bank Operation Plug in the power cord and connect load cables between load bank and EUT(Refer to above for connections) Push on button “Fan Power”,GREEN light will be on, fan working. Push on/off to adjust the load power, please refer to above form. When load test completed, please push off all load “Push Buttons”. Keep fan working for 10 to 20 minutes before push off “Fan Power” 5. Important Notice  Do not block the air flow of load bank fans. Keep fans working for around 10 to 20 minutes after test completed, to make sure the blower wind temperature same as indoor temperature.  The load bank will stop testing once “Fan Power” button is pushed off. 1 2 3 4 5

  5. JUNXY-AC230V-10KW-R AC Load Bank  The buzzer alarm when load bank over temperature, then please push off the load “Push Buttons” manually. If load bank temperature keeps increasing, the primary circuit contactor will be powered off, then load power will be switched off automatically. When load bank temperature becomes normal, the buzzer alarm will stop, could start test again.  Please inspect the screws every half year.  It is strictly prohibited if load bank is ungrounded. www.junxypowersolutions.com 6. JUNXY-AC230V-10KW-R AC Load Bank Circuit Diagram For better understand JUNXYAC load bank, please refer to the circuit diagram.

  6. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com

  7. JUNXY-AC230V-10KW-R AC Load Bank www.junxypowersolutions.com