IMPROVEMENT OF IMAGE QUALITY AND RADIATION DOSE REDUCTIONIN DIGITAL RADIOGRAPHY USING AN INTEGRATED WAVELET-TRANSFORM-BASED METHOD Haruyuki Watanabe 1 , Du-Yih Tsai 1 , Yongbum Lee 1 , Eri Matsuyama 1 , and Katsuyuki Kojima 2

kasie
Télécharger la présentation

BayesShrink

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IMPROVEMENT OF IMAGE QUALITY AND RADIATION DOSE REDUCTIONIN DIGITAL RADIOGRAPHY USING AN INTEGRATED WAVELET-TRANSFORM-BASED METHOD Haruyuki Watanabe 1, Du-Yih Tsai 1, Yongbum Lee 1, Eri Matsuyama 1, and Katsuyuki Kojima 2 1 Department of Radiological Technology, Graduate School of Health Sciences, Niigata University, Niigata, Japan 2 Department of Business Administration, Graduate School of Business Administration, Hamamatsu University, Hamamatsu, Japan Hip Joint (AP) Lumbar (lateral) Radiation dose ratio Input Image 1.0 10-4 1.25×10-2 Original * * * Original Original * * * ( a ) ( b ) ( c ) ( d ) ( e ) WF WF WF Wavelet decomposition 100/100 BayesShrink Sigmoid BayesShrink BayesShrink 0.8 10-5 1.24×10-2 Proposed Sigmoid × Sigmoid Sigmoid approximation coefficients detail coefficients (horizontal) detail coefficients (vertical) detail coefficients (diagonal) Proposed Proposed Proposed NPS (mm2) * Original * Sigmoid * * * 10-6 0.6 1.23×10-2 Improvement & denoising stage 80/100 BayesShrink MTF Gray Level Contrast Proposed WF Sigmoid-Type Transfer Curves for Wavelet Coefficients Weighting Adjustment Introduction Results j :decomposition level ( f ) ( g ) ( h ) ( i ) ( j ) 0.4 10-7 1.22×10-2 Original * * * wjoutput(m, n) : output value * * * * wjinput (m, n) : input value BayesShrink BayesShrink 64/100 The issue of radiationdose exposure to the patients with digital radiography is a major public health concern. It is known that a trade-off exists between noise level and radiation dose. On the one hand, high-dose radiation will lower the noise level, but may give excess radiation doses to the patient. On the other hand, low-dose radiation will lower the signal-to-noise ratio of the image and result in reducing the amount of image information. The balancing of dose and image quality should be performed explicitly to ensure that patient doses are kept as low as reasonable achievable, while maintaining a clinically acceptable image quality. To deal with this issue, much research, such as the development of new detectors and that of image processing methods has been carried out. In recent years, several investigators have reported that wavelet-based image processing techniques are effective in the reduction of radiation dose . Physical Properties Measurement WF 0.2 10-8 1.21×10-2 * * MTF NPS * Org Org Org Org Org Org Org Org * * * 0.0 * Original WF BayesShrink Sigmoid Proposed 10-9 Wavelet reconstruction 1.20×10-2 Pro Sig Pro Pro Pro Pro Pro Pro Figure 2 shows the MTFs for the original image and the four processed images. The MTF for the sigmoid shows the highest, followed by that for the proposed method. Both the MTFs are considerably superior to the original image over the entire spatial frequency range. In contrast, the MTFs obtained from the BayesShrink and the WF methods are slightly lower than the original one. Figure 3 shows the NPS values. The NPS values for the sigmoid method had a pronounced increase as compared to that of the original image. The NPSs values for the proposed method are slightly higher and similar to those of the original image. In contrast, the NPS values for the BayesShrink and WF methods decreased as compared to those for the original images. WF Sig Sig Sig Sig Pro Sig WF WF WF Bay Bay Bay Bay Bay Bay Bay WF WF WF WF Sig Sig Bay d :25 50/100 0 0 100/100 1 1 80/100 2 2 64/100 3 3 4 4 50/100 5 5 b :20 Spatial frequency (mm-1) Spatial frequency (mm-1) Radiation dose ratio Output Image - 1.0 - 1.0 - 1.0 - 1.0 - 1.0 - 1.0 - 1.0 - 1.0 - 0.5 - 0.5 - 0.5 - 0.5 - 0.5 - 0.5 - 0.5 - 0.5 0 0 0 0 0 0 0 0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 In this paper, we propose an improved wavelet-transform-based method for offering the possibility to reduce the radiation dose while maintaining a clinically acceptable image quality. The proposed method integrates the advantages of our previously proposed wavelet-coefficient-weighted method and the existing BayesShrink thresholding method. For verifying the effectiveness of radiation dose reduction in digital radiography, the proposed method was assessed quantitatively and qualitatively. Wavelet-Based Image Processing As shown in Figure 1, the proposed method for denoising radiographic images starts by decomposition of the original image by use of the discrete wavelet transform, which results in obtaining different detail wavelet coefficients (horizontal, vertical, diagonal). The three detail coefficients are then processed by use of a sigmoid-type transfer curve for adjustment of wavelet coefficient, followed by BayesShrink thresholding. Fig. 3 NPSs for the original image and the four processed images. Fig. 2 MTFs for the original image and the four processed images. GLC Visual Evaluation Sigmoid-type transfer curve for wavelet coefficient weighting adjustment (sigmoid) Proposed method Figure 4 shows the GLC as a function of the radiation dose ratio. The sigmoid and the proposed methods could considerably improve the GLC at a 64/100 radiation dose ratio with respect to the standard dose, although the value of the GLC with the sigmoid and proposed methods is slightly lower than the original image at 100/100 and 80/100 radiation dose level. Furthermore, the proposed method shows the highest performance among all images at the 50/100 radiation dose ratio. Figure 5 illustrates visual evaluation results for the hip joint and lumbar spine at various radiation dose ratios by use of Scheffe’s method. In terms of diagnostic acceptability, the proposed method provides significantly better results compared to those for the original image up to a 64/100 radiation dose ratio in the hip joint. When the radiation dose ratio was 50/100, no significant difference was found between the image processed by the proposed method and the original image. In the lumbar radiographs, the result obtained from the proposed method was comparable to the original image up to a 64/100 radiation dose rate. The sigmoid filter was used to enhance image contrast.The coefficients with great values and the coefficients of high resolution levels are heavily weighted. [%] N :maximum decomposition level c=d+b×ln(a-1.0) BayesShrink thresholding In the BayesShrink scheme, the threshold is determined for each subband by assuming a generalized Gaussian distribution (GGD). Fig. 1 Flow chart of the proposed method. TB:threshold value σ2 : noise variance M: median value Methods and Materials Fig. 5 Visual evaluation results using Scheffe’s method of paired comparisons of the original image (Org) and various images processed by the WF, BayesShrink (Bay), sigmoid (Sig), and the proposed (Pro) methods at each radiation dose ratio with respect to the standard dose. There was a significant difference (p < 0.01) between the original and the processed image at various dose ratios if the * mark is shown. In order to validate the superiority and effectiveness of the proposed method, we compared the proposed method with 3 conventional methods, namely, the Wiener filter (WF), BayesShrink method, and sigmoid-type method. In the wavelet-transform-based method, wavelet basis functions of Daubechies (order=4, level=4) were adopted for image processing. The proposed method and the above-described three methods were applied to the original images for performance comparison. Fig. 4 Gray-level contrasts as a function of the dose ratio for the original image and the four processed images obtained using a Burger phantom. Hip Joint (Antero-Posterior) Lumbar (Lateral) Sample image for measuring physical properties Filters Parameters ・Wiener filter (WF) kernel = 5 × 5 matrices Physical Properties Measurement ・BayesShrink (Bay) Daubechies, Order=4, Level=4 Modulation Transfer Function (MTF) ・Sigmoid (Sig) Daubechies, Order=4, Level=4 MTFs were measured with an angled-edge method. A tungsten plate (1 mm thickness) was used as an edge device.The direction of the edge was oriented with a small angle approximately 3˚. ・Proposed (Pro) Daubechies, Order=4, Level=4 Fig. 6 Original phantom images and the processed phantom images obtained using WF, BayesShrink, sigmoid, and the proposed methods for hip joint (a - e) and lumbar spine (f - j) at the standard dose. Conclusion Visual Evaluation Noise Power Spectrum (NPS) NPSs were measured with a 2D Fourier transform method. For the calculation, the central portion of each obtained uniform image was divided into 4 non-overlapping regions, 256×256 in size (80 in total). In this study, the experimental results demonstrated that the proposed method could improve the resolution and contrast characteristics while keeping the noise level within acceptable limits. Furthermore, our visual evaluation showed that an approximately 40 - 50% reduction in the exposure dose might be achieved with the proposed method. The proposed method has the potential to improve visibility in radiographs when a lower radiation dose is applied. A visual evaluation was conducted by five experienced radiological technologists.The images were displayed on a liquid crystal display. Statistical significance was tested using Scheffe’s method of paired comparisons. Conditions for the visual evaluation, including window level, window width, and display image size were fixed.The method of paired comparisons calculates the score of each image by comparative assessment between all possible pairs of images. Gray Level Contrast (GLC) GLCswere used to describe the relative contrast of the image, which were made using an acrylic disk (diameter : 8 mm, thickness : 8 mm)on the Burger’s phantom. CL: GLC value Lacrylic: mean pixel value in acrylic disk LBG : mean pixel value in background LD : gray level of CR system

More Related