1 / 3

W930 DVT sample failure analysis report

Confidential. W930 DVT sample failure analysis report. LICO Technology Corporation 4F,NO.4,Lane95 An-Shin Rd., Hsintien, Taipei Hsien 23159, Taiwan. TEL:+886-2-2211-6288 FAX:+886-2-2211-6068. Date : 2010/05/10 By Ariel_Huang. Confidential. Issue: Knob 晃動.

kelsie-kidd
Télécharger la présentation

W930 DVT sample failure analysis report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Confidential W930 DVT sample failure analysis report LICO Technology Corporation 4F,NO.4,Lane95 An-Shin Rd., Hsintien, Taipei Hsien 23159, Taiwan. TEL:+886-2-2211-6288 FAX:+886-2-2211-6068 Date : 2010/05/10 By Ariel_Huang

  2. Confidential Issue: Knob晃動 Latch與下蓋rib間隙過大(0.2mm),組裝後造成Knob晃動

  3. Confidential Solution: 1. 減少Latch與下蓋Rib組裝間隙,避免組裝後knob晃動問題 2. 修模Schedule: 修模時間: 5/5~5/10 樣品寄送時間: 5/10 樣品預計到貨時間: 5/12