1 / 23

BURLE INDUSTRIES Next Generation Large Area Low Cost PMT

BURLE INDUSTRIES Next Generation Large Area Low Cost PMT. UNO Collaboration Robert Caracciolo and Richard Leclercq 6 April 2005. BURLE INDUSTRIES. BURLE INDUSTRIES Overview. BURLE INDUSTRIES, INC. Conversion Tubes Power Tubes Real Estate BURLE ELECTRO-OPTICS, INC.

kelvin
Télécharger la présentation

BURLE INDUSTRIES Next Generation Large Area Low Cost PMT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BURLE INDUSTRIESNext Generation Large Area Low Cost PMT UNO Collaboration Robert Caracciolo and Richard Leclercq 6 April 2005 BURLE INDUSTRIES Aussois, France

  2. BURLE INDUSTRIES Overview BURLE INDUSTRIES, INC. Conversion Tubes Power Tubes Real Estate BURLE ELECTRO-OPTICS, INC. BURLE INDUSTRIES GmbH BURLE INDUSTRIES UK LIMITED BURLE deMexico Aussois, France

  3. Core Competencies • Conversion Tubes, Lancaster PA • Conventional PMT design and fabrication • Photocathode processing • Image tube design and fabrication • PMT Modules • Integrated VDN, HVPS, signal processing electronics • Power Tubes, Lancaster PA • Design and fabrication of vacuum tubes for power generation and switching • Plating and environmental testing • Ceramic-to-Metal joining techniques • BEO, Sturbridge MA • Microchannel plates • Channel multipliers • Fiber optics Aussois, France

  4. PMT Markets • Medical Imaging • Maintain ~ 30% market share and growing • Provide high-volume tubes for both SPECT and PET • Have presence in general spectroscopy, scintillation counting, and HEP • Targeting the HEP market more aggressively • Development of the PLANACON family • Cost competitive fast timing PMTs such as the 8575B. • SBIR grant to develop large area PMT Aussois, France

  5. Large Area PMT Program • Actively working on Phase II objectives of a DOE SBIR to develop a 20” diameter PMT with cost < $0.75/cm2 of active area, including VDN and cabling • Will also develop 2”, 5”, and 8” variants • Want to establish close ties with researchers associated with proton-decay and neutrino experiments to aid in development • Represents a BURLE commitment to becoming a major player in the HEP market Aussois, France

  6. Phase I Objectives • Define the required PMT performance specifications for future proton-decay and neutrino experiments. • Review potential PMT bulb designs that are cost-effective in high volume production while being consistent with the requirements in 1 above. • Review the various electron multiplier configurations available relative to cost and performance. • Consider methods of integrating the components of 2 and 3 to establish a PMT with the proper performance requirements and yet is cost effective for production. • Consider cost-effective manufacturing techniques for the PMT designs identified in 4 above. • Plan for the capital requirements for manufacturing PMTs as identified in 5 above for delivery times of 5 years and 8 years with quantity of 60,000 20” PMT equivalent. Aussois, France

  7. Requirements Aussois, France

  8. Multiplier Design Aussois, France

  9. Photocathode Design • Requirements for highest possible QE and lowest possible dark counts are in conflict. • Trade-study will be performed and initial PMT builds will be designed to optimize these parameters. Dark counts of 3kcps are possible, but QE will probably be limited to 20% max. • Electron multiplier design will influence the dark counts, and will be considered in that design Aussois, France

  10. Phase II Activities • Teamed with the Glass Technology Industry to develop the bulb, tooling, and manufacturing approach. • Establish a shape yielding good electron optics and mechanical integrity • Electron optics studies to establish novel focusing methods • Design, tool, and fabricate the electron multiplier. • Modify existing exhaust equipment to manufacture prototype PMTs. • Manufacture and test prototype PMTs. • Perform environmental tests on prototype PMTs including pressure, shock/vibration, and temperature. • Adapt existing process equipment for low-cost manufacturing. Aussois, France

  11. Bulb Designs • Mushroom Shape • Good for electron optics • Large neck area allows for focusing electrode • Manufacturing approach does not yield consistent results leading to lower mechanical reliability • Design is not conducive to modern glass manufacturing technology Aussois, France

  12. Bulb Designs • Simple shape, easy to blow • Good for electron optics if mount is elevated to middle of bulb • Excellent mechanical strength • Larger volume than is necessary • Small neck implies simpler sealing techniques Aussois, France

  13. Bulb Designs • Possible methods to make this shape highly automated • Good for electron optics except for edge TTS • Good mechanical strength • Mount is lower in bulb • Good use of volume • Small neck implies simpler sealing techniques Aussois, France

  14. System Design Aussois, France

  15. System Design Aussois, France

  16. Ideal Front End Optics • Truncated bulb • Uniform E-field in front of cathode • Small neck • TTD ~ 1.5 ns Aussois, France

  17. Electron Optics Optimization • Different Vectors for Simulations • 2 INCH • 5 INCH • 8 INCH • 20 INCH • Build prototypes and test Aussois, France

  18. 2 INCH 3D-MODEL Aussois, France

  19. Coincidence Resolving Time LSO 4*4*20 mm Test PMT ¾” PMT Na22 CFD CFD TPHC Stop Start 1 2 Delay 5 1 3 MCA 4 Aussois, France

  20. 8575B 2 Inch Prototype TTD(ns) FWHM(ns) 0.120.38 0.00 0.49 0.80 -0.210.25 0.00 0.05 0.12 0.800.91 0.71 0.84 0.97 0.990.92 0.82 0.97 0.94 Aussois, France

  21. 2 INCH Anode Uniformity Aussois, France

  22. General Milestones • 5 Inch PMT 2nd Quarter 05 . Compare with 8854 . Sample to Stony Brook . Pressure Test • 8 Inch PMT 2nd Quarter 06 • 20 Inch PMT 4th Quarter 06 Aussois, France

  23. Summary • Interfacing with glass and bulb manufacturers to optimize cost-effective bulb design. • FEA and environmental testing to validate mechanical integrity of bulb. • Employing 2-D and 3-D electron optics models. • Cathode to Dy1 fields • Dy1 to the electron multiplier fields • Design and implement novel focusing elements. Required for a bulb with a small neck. • Validated our design concepts on the 2” PMT. Will continue with the 5”, 8”, and 20” PMT’s. • Reviewing different photocathode processes and or design to optimize balance of QE and Dark counts. Aussois, France