1 / 16

Juan Chen 1 , Sabine Thielges 2 , William R. Porter 3 , Jyh-Ming Shoung 1 , Stan Altan 1

Comparison of Shelf Life Estimates Generated by ASAP prime TM with the King-Kung-Fung Approach. Juan Chen 1 , Sabine Thielges 2 , William R. Porter 3 , Jyh-Ming Shoung 1 , Stan Altan 1. 1 Nonclinical Statistics and Computing, Janssen R&D 2 BE Analytical Sciences and COES, Janssen R&D

kolya
Télécharger la présentation

Juan Chen 1 , Sabine Thielges 2 , William R. Porter 3 , Jyh-Ming Shoung 1 , Stan Altan 1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comparison of Shelf Life Estimates Generated by ASAPprimeTM with the King-Kung-Fung Approach Juan Chen1, Sabine Thielges2, William R. Porter3, Jyh-Ming Shoung1, Stan Altan1 1Nonclinical Statistics and Computing, Janssen R&D 2BE Analytical Sciences and COES, Janssen R&D 3Peak Process Performance Partners LLC

  2. Content • Arrhenius Equation and Extensions to include Humidity Effects • Extended Arrhenius Equation • Extended King-Kung-Fung (KKF) Model • ASAP Approach • Zero order, 2-temperature Example • Case Study using Pseudo-data • DoE of Pseudo-data • Comparison of Outputs from ASAP and KKF Model • Conclusion

  3. Arrhenius Equation Named for Svante Arrhenius (1903 Nobel Laureate in Chemistry) who established a relationship between temperature and the rates of chemical reaction: Where kT= Degradation Rate A = Non-thermal Constant Ea= Activation Energy R = Universal Gas Constant (1.987 cal/mol) T = Absolute Temperature

  4. Arrhenius Equation with Humidity Term A humidity term with coefficient B is introduced to account for the effect of relative humidity on rate parameter. activation energy humidity sensitivity factor degradation rate Pre-exponential factor gas constant (1.987cal/mol)

  5. Extended King-Kung-Fung Model King-Kung-Fung (KKF) model is widely used for analyzing accelerated stability data Let T =298oK (25oC) H = 60 • Directly estimate Shelf Life (SL) at 25C/60%RH and its uncertainty • Parameter estimates are calculated based on the Arrhenius relationship conditional on an assumed zero order kinetic • Can be further extended to a nonlinear mixed model context and Bayesian calculation

  6. Introduction to ASAPprimeTM The ASAPprimeTMcomputerized system is a computer program that analyzes data from accelerated stability studies using a 2-week protocol accommodating both temperature and humidity effects through a extended Arrhenius model. The program makes a number of claims: • Reliable estimates for temperature and relative humidity effects on degradation rates, • Accurate and precise shelf-life estimation, • Enable rational control strategies to assure product stability. These claims require careful statistical considerations of the modeling strategies proposed by the developers. Our objective is to evaluate the first two claims in relation to widely accepted statistical approaches and considerations.

  7. Illustration of ASAPprimeTMApproach Shelf Life (SL) Estimation using Zero-order, 2-Temperature Example Data SD Hierarchy: 1. Calculate from replicate data , if >LOD 2. User-defined SD (fixed) or RSD, if >LOD 3. Default 10%RSD, if >LOD 4. LOD • Calculate SD of SL at accelerated conditions = Mean SL – Extrema SL • Method of SD calculation is not consistent with the standard definition of a SD • No a priorivariance structure proposed for analytical variability in terms of a statistical model  The uncertainty in the SL estimates cannot be understood in relation to statistical principles; empirical comparisons only Mean SL Extrema SL

  8. Error propagation through a MC simulation Pairs of lnK at 50C and 60C form 49 regression lines across 1/T with slopes (=Ea/R) and intercepts (lnA) • Calculate lnK at 25C for each simulation: lnK = lnA – Ea/(RT) • Simulation was drawn from an undocumented distribution. • Arrhenius parameters (lnA and Ea) are determined from simulated degradation rates Statistical properties of the estimated lnA and Eaare not unknown.

  9. ASAP Probability statement about lnK and SL at 25C • SL at 50C and 60C previously simulated from an unknown distribution Cannot verify lognormal distribution at 25C • Model fitting cannot be confirmed by standard statistical procedures.

  10. Case Study using Pseudo-data • 4 x 4 factorial design of temperature and humidity • 9 sets of data simulated from combinations of D0, Ea, B values each at L, M, H, 73-day sampling design assuming a zero-order model • lnA back-calculated to obtain SL at 2 years at 25C/60%RH • Normally distributed random errors with mean 0 and SD 0.1 were added as analytical variability

  11. KKF model carried out in SAS Procnlin(Initial values: SL = 0.27 year, Ea = 10, B = 0.001, D0 = 0) • KKF estimated residual errors range from 0.08 to 0.12, whereas the true value is 0.1 • ASAP different user specified SD affect probability statement about SL

  12. ASAP generally underestimated the shelf life. • KKF estimated SL were generally closer to true values than ASAP. ASAP generally underestimated lnA.

  13. ASAP generally underestimated Ea. Standard errors of Ea are affected by user specified SD, and are generally larger than KKF estimates.

  14. ASAPunderestimated B for data HHH and HLH, and overestimated B for LLL. Standard errors of B are affected by user specified SD, and are generally larger than KKF estimates.

  15. Conclusion • Uncertainty measure for ASAP estimated shelf life is derived from an “error propagation” calculation using either replicate error or a user defined quantity. • Statistical rationale for uncertainty limits is not clear. • Does not lead to a statistical confidence statement. • ASAP simulation of SL to predict room temperature SL: • Underlying distribution of SL at accelerated conditions is not documented. • The precision of Arrhenius model parameter estimates is influenced by user specified SD and cannot be validated statistically. • Overall model fitting is unclear and lacks documentation. • Manufacturing variability cannot be accommodated.

  16. Thank You!

More Related