1 / 15

Integrating Non-Standard Devices with TOP Server UCON

Learn how to integrate your non-standard devices with TOP Server UCON for plant floor data accessibility. Explore user-configurable solutions, key features/benefits, protocol creation, live demos, UCON commands/settings, and real-world case studies. Don't miss this opportunity to address integration challenges and achieve real-world excellence.

krider
Télécharger la présentation

Integrating Non-Standard Devices with TOP Server UCON

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TOP Server UCON: Integrating Your Non-Standard Devices Presenter: Kevin Rutherford, Senior Applications Engineer

  2. Agenda • Overview of User Configurable Solutions • TOP Server UCON Key Features/Benefits • Protocol Creation with UCON • Live UCON Demo • UCON Commands/Settings • Protocol Creation: Barcode Walkthrough • UCON Case Study: Real World Success • Summary / Q&A

  3. How Do You Get Plant Floor Data at Your Fingertips? What Types of Devices Are On Your Plant Floor? PLC’s (Allen-Bradley, Modbus, Siemens, Fanuc…) DCS Systems Other Systems/Devices With a Standard Protocol Standard I/O Servers for Standard Protocols What If You Have Devices with a Non-Standard Protocol? No Standard I/O Servers for Non-Standard Protocols

  4. Real World Devices:A “Zoo” of Non-PLC Hardware Ethernet: TCP/IP, UDP, Telnet, RS-232, RS-422, RS-485 Message Displays & Scoreboards Gas analyzers Barcode Printers Bar Code Scanners i.e. Intermec, Symbol, Z-Tron Linear Scales i.e. Mitutoyo, Digimatic Measuring Systems Laser Marking Systems Combustion Analyzers Gas Chromatographs Weigh Scales Mass Spectrometers iFIX PDB Custom/Other Applications

  5. Real World Excellence is Not Possible with Traditional Solutions Traditional Solutions for Non-Standard Device Connectivity Custom Driver Development Interface Device to a PLC (Basic Module) Pick Device that Integrates with Your Existing Standards Manual Data Entry/Collection Abandon Integration Entirely Traditional Solutions Are: • Expensive • Error prone • Unreliable • Inflexible • Hard to Maintain • High Risk

  6. Every Industry Faces Integration Challenges Food & Beverage Barcoding, RFID, Printers, Weigh Scales Pharmaceutical Serialization, Barcode, RFID, Weigh Scales Packaging Barcode, Printers, RFID, Weigh Scales Power Generation Emissions Monitoring equipment The Lists/Examples Number in the Thousands So How Do You Address Such Integration Challenges?

  7. Real World Excellence Demands New Device Integration Solutions New Challenges Product Traceability Customer Demands/Expectations Regulatory Requirements New Approaches “Don’t Integrate” Not an Option Leverage Existing Standards (i.e. OPC) Leverage Off-the-Shelf Tools Leverage the Experience of Others Custom Code/Applications are a Last Resort New Approaches Result In: • Lower Engineering Costs • Lower Risks • Flexibility • Business Decisions using Real Data

  8. User Configurable Drivers:Flexible, Off-the-Shelf Solutions OPC Suitelink User Configurable OPC & IO Server DDE RS-232/422/485 Or Ethernet Any of the thousands of devices that you must integrate with

  9. TOP Server UCON:Key Features / Benefits • Key Features • Use in your TOP Server with other “standard” drivers – SINGLE interface • Serial and Ethernet • Solicited and Unsolicited • Key Benefits • Flexible Data Parsing • Fixed Length • Delimited Data • By Specified Length Byte • Scripting Based Parsing • Conditional Processing • Powerful Diagnostics • Protocol / Channel • OPC • Verbose Event Log • Saves You Money in Design & Startup

  10. Example Protocols Barcode Scanner Weigh Scale Modbus RTU

  11. Interpretation of Protocol Commands • Engineer Defines Once: • Command Format to Send to Device (if necessary) • What Format of Device Response Looks Like (if applicable) • Where Desired Data is in Response

  12. TOP Server • Live Demonstration • Common Commands / Settings • Protocol Walkthrough: Barcode Scanner

  13. Case Study – BHP Billiton/Mozal System Platform 3 w/ InTouch 9.5 “Saveway” Weigh Scales Metals & Mining Industry Implemented in < 1 day of effort

  14. Steps to Success w/ UCON Obtain Protocol Documentation for Your Device Look for Available Message Samples Determine Specific Commands Needed Know What Data You Need to Read/Write Start Simply to Prove Connectivity Contact Us! Complimentary Protocol Evaluations Tips & Recommendations for Getting Started

  15. Contact Information & Other Learning Opportunities • Questions later? • Kevin Rutherford • krutherford@softwaretoolbox.com • 888-665-3678 or 704-849-2773 • support@softwaretoolbox.com • www.toolboxopc.com/html/ucon1.html • www.softwaretoolbox.com • Other learning opportunities • Visit www.softwaretoolbox.com/webinars