An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FM Electronics Product Information & Product Finder Find Part by Description I need POLICE response Audible only (Bells only) 8000 series External 4000 series Class 3 4000 series Class 6 I Know the Part Number Link to website EXIT TO WINDOWS TIP: You can press the Esc key to exit this programme at any time

  2. For Police response the system MUST be: 1: Installed by an Inspectorate recognised company. 2: Be monitored by an Alarm Receiving Centre (ARC). 3: Be maintained by an Inspectorate recognised installer. (Alarm Inspectorate usually = NACOSS or SSAIB) Are you Inspectorate recognised? Not Inspectorate Recognised Inspectorate Recognised

  3. You need an inspectorate recognised company for this installation, If You heard about our product from an alarm installer you will need your installer to supply and fit the system, we supply trade only. If From another source, (Internet etc..) Look in your telephone directory for NACOSS or SSAIB recognised installers who can assist you or contact FM Electronics who will give you contact details for your nearest installer(s). Return to Main Menu

  4. You require the FM4000 series product How many zones do you require? Up to 8 zones (circuits) Up to 64 zones (circuits) More than 64 zones (circuits)

  5. We do not have a single panel with more than 64 zones, please contact your installation company or Technical Support at FM Electronics on 01594 827070 for further assistance. Return to main menu Back to panel menu

  6. FM4000 8 Zone Control Panel + Fire & Panic zones plus up to 8 set/unset devices (keypads or remote controls in any combination) Dimensions 270mm wide x 155mm tall x 80mm deep approx. Requires a 12V 2.1Ah battery. Our part no. BAT1. Connections required = mains supply, external sounder & communications device (digi, stu etc.) Absolute maximum working range from furthest device to the control panel 100 metres (this is measured in free space.) The actual maximum working range achieved will vary from site to site and signal strength should be checked before installation is commenced. Checking signal strength Exit to Main Menu Devices for this panel

  7. Detection Devices Set/Unset Devices 4180 Radio Keypad 4650-GB Contact Transmitter 4660-GB Smoke Detector 4173-GB Remote control 4600-GB Infra-red detector Accessories 4005 Tamper Module 4007 Remote Antenna 4655 Inertia transmitter Exit to main menu Back to FM4000 menu

  8. Signal strength can be measured using the control panel, a transmitting device (pir, contact, remote control etc.. (the remote is the easiest) a 12V battery for the control panel and a volt meter. To test the strength, position the panel in it’s proposed location,power up the control panel (just the 12v battery is sufficient) connect a voltmeter with the DC range selected across the two terminals inside the control panel labelled DVM and press the reset switch, just to the right of the connections terminals. The meter should now read 0V. Go to the required location for the furthest device and send a learn signal from the transmitter (or a PA from a remote control.) The panel will now latch the received signal strength from the device at the panel. (Contact Technical Support at FM Electronics on 01594 827070 if further details are required.) Return to Panel Menu Return to Main Menu

  9. FM4000X & FM4001(used together) 64 Zone Control Panel + 8 Fire & 8 Panic zones plus up to 8 set/unset devices (keypads or remote controls in any combination) Dimensions 270mm wide x 320mm tall x 80mm deep approx. Requires a 12V 2.1Ah battery. Our part no. BAT1 Connections required = mains supply, external sounder & communications device (digi, stu etc.) Absolute maximum working range from furthest device to the control panel 100 metres (this is measured in free space.) The actual maximum working range achieved will vary from site to site and signal strength should be checked before installation is commenced. Checking signal strength Exit to Main Menu Devices for this panel

  10. FM4000E 8 Zone control panel FM4000 8 Zone control panel FM4000X & FM4001, 64 control panel 4005 Tamper module 4007 Remote antenna 4100-GB Infra-red detector 4150-GB Contact transmitter 4155 Inertia transmitter 4160-GB Smoke detector 4173-GB Remote control 4180 Radio keypad 4600-GB Infra-red detector 4650-GB Contact transmitter 4655 Inertia transmitter 4660-GB Smoke detector None of the these?

  11. FM8000-BNC 8 Zone control panel FM8016 Indicator panel R1 Single Zone receiver 8008 8 Zone receiver FSM Engineers test receiver R1B Plug in receiver RP2 Repeater station TPHP 10mW PA transmitter DK3-HP Radio keypad TR4-HP Remote control TSD-HP Smoke detector 10GP General purpose TX PEN-173 Pendant PA transmitter 125-HP High power PIR 115H-HPWP Horizontal curtain PIR None of the these?

  12. 125-HPWP General purpose PIR 145-HPWP Corridor PIR HG1 High gain antenna HG2 Directional antenna HS1 Right angle stub antenna HS2 Straight stub antenna 6143 Mains relay timer unit 6501 Transistor relay module SA1 External bell box DSA1 Dummy bell box 2100 SD1+ autodialler SB Swivel bracket for external pir’s BAT1 12Volt 2.1 Ampere hour battery BAT2 9Volt alkaline battery BAT3 9Volt lithium battery None of the these?

  13. BAT4 12Volt N-cell battery BAT5 Lithium coin cell BAT6 1.5Volt AA cell BAT7 12Volt for Ramtech BAT100 100 x BAT2 Better price BAT240 240 x BAT2 Better price BAT 525 25 x BAT5 Better Price BAT640 40 x BAT6 Better Price 142012 inertia sensor LENSPACK 2 alternative lenses None of the these? Back to start of list. Escape to main Menu

  14. Ring Technical Support at FM Electronics for further assistance on 01594 827070. Return to previous page Exit to Main Menu

  15. Detection Devices Set/Unset Devices 4180 Radio Keypad 4650-GB Contact Transmitter 4660-GB Smoke Detector 4173-GB Remote control 4600-GB Infra-red detector Accessories 4005 Tamper Module 4007 Remote Antenna 4655 Inertia transmitter Exit to main menu Back to FM4000X menu

  16. 4650-GB Contact Transmitter Designed to detect the opening of doors, windows etc. This unit has a built in back tamper, lid tamper & reed switch that can be used with a magnet of your choice. Please note a magnet is not supplied with this unit. Dimensions 40mm wide x 160mm tall x 28mm deep approx. Can be connected to any normally closed detection device with a normally closed tamper loop. Can be connected to any normally open push to set, where a push to set button is required. Can be used for both push to set and detection at the same time. Powered by 2 AA batteries, our part number BAT6 Exit to main menu Exit to previous slide

  17. 4660-GB Optical Smoke Detector This OPTICAL (sometimes known as photoelectronic) smoke detector is usually better than an ionisation type smoke detector as this detection device will not react as readily to nuisance alarms (cooking fumes etc.) this type of detector reacts best to slow smouldering fires. The detector head conforms to BS5446 part 1-1990 The detector is powered by a 9V PP3 size alkaline battery our part no BAT2. The transmitter is powered by 2 AA batteries, our part number BAT6. (Note. our fire detection system does not conform to BS5839) Exit to main menu Exit to previous slide

  18. 4600-GB General Purpose PIR Dimensions 63mm wide x 110mm tall x 60mm deep approx. 12 metre 90 degree general purpose pir. This unit has 3 pulse count selection options, with a choice of single, 2 or 4 pulses required to generate an alarm condition. Ideal mounting height = 2.2 metres (max.= 2.5 metres.) 2 interchangable lenses are available for this unit. (see LENSPACK below) Powered by 2 AA batteries, our part number BAT6 Batteries should be changed annually. LENSPACK Exit to main menu Exit to previous slide

  19. LENSPACK 2 Interchangeable lenses for the 4000 series PIR’s Lens 1: A 10 metre horizontal curtain lens (sometimes known as a ‘pet alley’). When this lens is fitted and the pcb inside the detector is positioned as far down as the tilt adjustment will allow, this detector will ignore any movement below the height at which it is mounted. Not suitable for use where the pet may climb to higher surfaces. (FM part no 366 009) Lens 2: A 25 metre corridor lens, with 4 creep zones. (FM part no. 366 008) Exit to main menu Exit to previous slide

  20. 4600-GB General Purpose PIR Dimensions 63mm wide x 110mm tall x 60mm deep approx. 12 metre 90 degree general purpose pir. This unit has 3 pulse count selection options, with a choice of single, 2 or 4 pulses required to generate an alarm condition. Ideal mounting height = 2.2 metres (max.= 2.5 metres.) 2 interchangable lenses are available for this unit. (see LENSPACK below) Powered by 2 AA batteries, our part number BAT6 Batteries should be changed annually. LENSPACK Exit to main menu Exit to previous slide

  21. 4655 Inertia Transmitter Designed to detect the vibration caused by the forcing open of doors, windows etc. Dimensions : transmitter 40mm wide x 160mm tall x 28mm deep - sensor 20mm x 45mm x 15mm deep + 2metres of cable. Sensitivity adjustment inside unit with an LED to indicate vibration required to activate the unit. Supplied with 1 sensor. For optimum system performance use 1 transmitter with 1 sensor. An additional sensor can be wired in series if required, our part no. 142012. (2 sensors per transmitter is the maximum recommended). Powered by an alkaline PP3 battery, our part number BAT2 142012 Sensor Exit to main menu Exit to previous slide

  22. 4173-GB Remote Control 3 button remote control, designed to unset, part set, fully set or activate a Panic alarm on any 4000 series control panel. The panic is activated by pressing the unset and the full set buttons together. Green LED on the front of the unit illuminates when the unit is operated to indicate the battery is still serviceable. Batteries typically will last 2 years in normal use. Powered by 2 CR2032 batteries, our part number BAT5. Exit to main menu Exit to previous slide

  23. 4600-GB General Purpose PIR Dimensions 63mm wide x 110mm tall x 60mm deep approx. 12 metre 90 degree general purpose pir. This unit has 3 pulse count selection options, with a choice of single, 2 or 4 pulses required to generate an alarm condition. Ideal mounting height = 2.2 metres (max.= 2.5 metres.) 2 interchangable lenses are available for this unit. (see LENSPACK below) This device is supervised at approximately 20 minute intervals. Powered by 2 AA batteries, our part number BAT6, battery life 1 year. LENSPACK Exit to main menu Exit to previous slide

  24. 4180 Radio Keypad A radio keypad designed to unset, part set, fully set or activate a Panic alarm on any 4000 series control panel. The panic is activated by pressing any two vertical keys from the top three rows together. Green LED on the front of the unit illuminates when the unit is operated to indicate a correct code has been entered. An audible warning will sound from the keypad if the keypad battery is near to the end of it’s service life. Batteries typically will last 1 year in normal use. Powered by a quality alkaline PP3 size battery, our part number BAT2 Exit to main menu Exit to previous slide

  25. 4100-GB General Purpose PIR Dimensions 63mm wide x 110mm tall x 60mm deep approx 12 metre 90 degree general purpose pir. This unit has 3 pulse count selection options, with a choice of single, 2 or 4 pulses required to generate an alarm condition. Ideal mounting height = 2.2 metres (max.= 2.5 metres.) 2 interchangable lenses are available for this unit. (see LENSPACK below) Powered by 2 AA batteries, our part number BAT6 Batteries should be changed annually. LENSPACK Exit to main menu Exit to previous slide

  26. 4150-GB Contact Transmitter Designed to detect the opening of doors, windows etc. This unit has a built in back tamper, lid tamper & reed switch that can be used with a magnet of your choice, note a magnet is not supplied with this unit. Dimensions 40mm wide x 160mm tall x 28mm deep approx Can be connected to any normally closed detection device with a normally closed tamper loop. Can be connected to any normally open push to set, where a push to set button is required. Can be used for both push to set and detection at the same time. Powered by 2 AA batteries, our part number BAT6 Exit to main menu Exit to previous slide

  27. 4155 Inertia Transmitter Detects the vibration caused by forcing doors, windows etc. Dimensions : transmitter 40mm wide x 160mm tall x 28mm deep - sensor 20mm x 45mm x 15mm deep + 2 metres of 4 core alarm cable Sensitivity adjustment inside unit with an LED to indicate vibration required to activate the unit. Supplied with 1 sensor. For optimum system performance use 1 transmitter with 1 sensor. An additional sensor can be wired in series if required, our part no. 142012. (2 sensors per transmitter is the maximum recommended). Powered by an alkaline PP3 battery, our part number BAT2 142012 Sensor Exit to main menu Exit to previous slide

  28. 4160-GB Optical Smoke Detector This OPTICAL (sometimes known as photoelectronic) smoke detector is usually better than an ionisation type smoke detector as this detection device will not react as readily to nuisance alarms (cooking fumes etc.). This type of detector reacts best to slow smouldering fires. The detector head conforms to BS5446 part 1-1990 The detector part of this unit is powered by a 9V PP3 size alkaline battery. Our part no BAT2. The transmitter part of this unit is powered by 2 AA batteries, our part number BAT6 (Please note our fire detection system does not conform to BS5839). (Probably better to use 4660-GB for fire systems.) Exit to main menu Exit to previous slide

  29. FM8000 Control Panel 8 Zone Control Panel + Fire & Panic zones Can accept any number set/unset devices (keypads and/or remote controls in any combination) Dimensions 270mm wide x 155mm tall x 80mm deep. Requires a 12V 2.1Ah battery. Our part no. BAT1. Connections = Mains supply, clean contact relays for external sounder, strobe & Autodialler (SD1+, Vocalizer etc.) 12 Volt Auxiliary power supply rated at 0.5Amp continuous 1 amp intermittent. The radio range from the detection devices to the panel should be checked before each installation (Maximum 500 metres) Devices for this panel Exit to Main Menu Back to previous page

  30. Detection Devices Set/Unset Devices 4150-GB Contact Transmitter 4160-GB Smoke Detector 4173-GB Remote control 4180 Radio Keypad 4100-GB Infra-red detector Accessories 4007 Remote Antenna 4155 Inertia transmitter Exit to main menu Back to Previous slide

  31. 4005 Antenna Tamper Module (For 4007 Antenna) All antenna’s connected to CLASS 6 systems must be tamper protected, either mechanically, electronically or by any combination of the two techniques. This tamper module checks the integrity of the connection between the antenna and the module, creating a tamper fault if this connection is lost. The unit is designed to be connected in series with the tamper loop, generating a tamper fault on the control panel if this connection is lost. There is an indicator fitted to the module to indicate to the engineer the tamper fault originates from the antenna module. Fits inside any of the FM4000 series panels. 4007 Antenna Exit to main menu Exit to previous slide

  32. 4007 Remote Antenna A dipole antenna suitable for use with the 4005 module on Class 6 systems or on it’s own on Class 3 systems. Supplied with 10 metres of co-axial cable, which should be cut to the minimum length required at the point of installation. The cable should never be extended or joined. When a remote antenna is used, the antenna inside the control panel should be disconnected (preferably removed completely). The Antenna should be mounted vertically (one end is labelled TOP), the cable should come out at 90 degrees to the antenna and must not run against the antenna housing especially the top part of the antenna. 4005 Module Exit to main menu Exit to previous slide

  33. FM4000E 8 Zone Control Panel + Fire & Panic zones plus up to 8 set/unset devices (keypads or remote controls in any combination) Dimensions 270mm wide x 155mm tall x 80mm deep. Requires a 12V 2.1Ah battery. Our part no. BAT1. Connections = For mains supply, external sounder & Autodialler. Absolute maximum working range from furthest device to the control panel 100 metres (this is measured in free space.) The actual maximum working range achieved will vary from site to site and signal strength should be checked before installation is commenced. Checking signal strength Exit to Main Menu Devices for this panel

  34. External panel/receiver selector. FM8000 series Panels Receiver / Interfaces FM8000-BNC 8 Zone control panel 8008 8 zone receiver R1 Single zone receiver FM8016 Indicator panel R1B Plug in receiver Test Equipment Repeater FSM Engineers test receiver RP2 Repeater station

  35. FM8016 Indicator Panel 14 zones, tamper & low battery indication This panel is typically used with panic buttons or smoke detectors, where 24 hour protection is required. Dimensions 270mm wide x 155 tall x 80mm deep. Requires a 12V 2.1Ah battery. Our part no. BAT1. Connections = Mains supply, clean contact relays for external sounder, strobe & Autodialler (SD1+, Vocalizer etc.) 12Volt Auxiliary power supply rated at 0.5Amp continuous 1 amp intermittent. Back to previous menu Exit to Main Menu Devices for this panel

  36. Do you require a FOB (Push button transmitter) for the 4000 series or the 8000 series? 4000 Series 8000 Series

  37. You require the 4173-GB, 3 button remote control. More information about this device Back to main menu Back system select menu

  38. Do you require a single button unit or a four button unit? Single Button Four Button

  39. You require a TR4-HP More information about the TR4-HP Back to main menu Back system select menu

  40. Do you require a hand held unit or a pendant (necklace type) unit? Hand held Pendant

  41. The part number you require is TPHP More information about this device Back to main menu Back to system select menu

  42. The part number you require is PEN 173 NOTE:- YOU MUST KNOW THE SITE CODE AND THE ZONE NUMBER. BEFORE ORDERING THIS UNIT THESE ARE FACTORY PRESET AND NOT USER AJUSTABLE. IF IN DOUBT CONTACT TECHNICAL SUPPORT AT FMELECTRONICS ON 01594 827070 More information about this device Back to main menu Back to system select menu

  43. TR4-HP Remote Control 4 button remote control, designed to unset, part set, full set or activate a Panic alarm on the FM8000 control panel. The buttons from left to right are Unset (Black), Part Set (Grey), Full Set (grey) & Panic (red), these buttons are protected by a sliding cover to prevent accidental operation. Green LED on the front of the unit illuminates when the unit is operated to indicate the battery is still serviceable Typically the battery will last 1 year in normal use. Powered by 1 quality alkaline PP3 size battery, our part number BAT2 Maximum radio range 500 metres, the maximum will vary from site to site and should be checked at each installation. Exit to main menu Exit to previous slide

  44. TPHP Hand held Panic Transmitter Operated by a single Red button, which can be protected from accidental operation by a sliding cover. The unit can be user programmed to send any site code and zone to any receiver in the 8000 series product range. Green LED on the front of the unit illuminates when the unit is operated to indicate the battery is still serviceable Typically the battery will last 1 year in normal use. Powered by 1 quality alkaline PP3 size battery, our part number BAT2 Absolute maximum radio range 500 metres. (This is under ideal conditions), the actual range achieved will vary from site to site and should be checked at each installation. Exit to main menu Exit to previous slide

  45. PEN173 Pendant Panic Transmitter Operated by pressing a single button, on the front of the unit or by breaking the neck cord. The unit is FACTORY PROGRAMMED to send the required site code and zone. (We MUST know which SITE CODE & ZONE is required, before an order is placed). Green LED on the front of the unit illuminates when the unit is operated to indicate the battery is still serviceable Powered by 1 Quality Alkaline N cell, our part number BAT4 this will last 1 year in normal use. Absolute maximum radio range 100metres. (This is under ideal conditions), the actual range achieved will vary from site to site, and should be checked at each installation. Exit to main menu Exit to previous slide

  46. Remote Controls & Keypads. Detection Devices TR4-HP Remote control 115H-HPWP 10 Metre horizontal PIR 125-HPWP 12 Metre general purpose PIR DK3-HP Radio keypad 145-HPWP 35 metre corridor PIR Panic Buttons Select your panic button here 10GP General purpose transmitter

  47. Do you require a hand held unit or a pendant (necklace type) unit? Hand held Pendant

  48. The part number you require is TPHP More information about this device Back to main menu Back to controls, panic & detection devices.

  49. The part number you require is PEN 173 NOTE:- YOU MUST KNOW THE SITE CODE AND THE ZONE NUMBER. BEFORE PLACING AN ORDER FOR THIS UNIT THESE ARE FACTORY PRESET AND NOT USER AJUSTABLE. IF IN DOUBT CONTACT TECHNICAL SUPPORT AT FM ELECTRONICS ON 01594 827070 More information about this device Back to main menu Back to controls, panic & detection devices.

  50. DK3-HP Radio Keypad A radio keypad designed to unset, part set, full set or activate a Panic alarm on the FM8000 control panel. The panic is activated by pressing any two vertical keys from the top two rows together. Green LED on the front of the unit illuminates when the unit is sending it’s signal to the control panel. An audible warning will sound from the keypad if the battery is near to the end of it’s service life. The Battery typically will last 1 year in normal use. Powered by a quality alkaline PP3 size battery, our part number BAT2 Exit to main menu Exit to previous slide

More Related