html5-img
1 / 14

Bremen 6.12.2010

Limb tracegases : verification with scientific processors K-U- Eichmann, C. von Savigny , H. Bovensmann , A. Kokhanovsky , (presented by M. Weber). Bremen 6.12.2010. IUP & DLR limb ozone retrieval:. IUP V2.1 (L1 V6/V7):

lois-pratt
Télécharger la présentation

Bremen 6.12.2010

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Limb tracegases: verification with scientific processorsK-U- Eichmann, C. von Savigny, H. Bovensmann, A. Kokhanovsky,(presented by M. Weber) Bremen 6.12.2010

  2. IUP & DLR limb ozone retrieval: IUP V2.1 (L1 V6/V7): central wavelength of the Chappuis triplet is shifted from 601 to 589 nm Tikhonov parameter linearly decreases with altitude from 9 at 72 km to 3 at 7 km instead of constant value of 6 IUP V2.2: Foward model is changed from SCIATRAN 2.2 to SCIATRAN 3.0 Spectral region: 2 nm spectral intervals centered around: 264 nm, 267.5, 273, 283, 286, 288, 290.5, and 305 (UV) as well as 525, 589, and 675 nm (Chappuis band) Surface albedo: geographical database [Matthews, 1983] IUP V2.3: Use of a latitude dependent aerosol climatology ECSTRA [Bingen, 2000] OP 5.1 (DLR operational retrieval on L1 V7 ) DOAS retrieval in Chappuis band altitude coverage: 15-40 km (IUP retrieval: 10-70 km)

  3. Differences between IUP 2.1/2.3 and OP5 • The differences between the IUP 2.1 and 2.3 are found mainly below 33 km down to the tropopause. • These are mainly due to the use of the ECSTRA aerosol climatology in IUP2.3. Another reason could be different p/T inputs, IUP uses ECWMF data.

  4. Limb Ozone Verification: OP5.01 vs. ST2.3 201001-03 200301-04 Verification of OP5 with SCIATRAN 2.3: 4 months of data in 2003 and 2010 were used. OP5 ozone is on average about 8% higher for all tangent heights. Results are similar for the years 2003 and 2010.

  5. O3: Latitude dependency (200301-04) N25-50 N50-90 -25-+25 N50-90: +10% N25-50: +6% -25/25 : +10% S25-50: +8% S50-90: +6% S50-90 S25-50

  6. 70-90 50-70 30-50 O3: Sun zenith angle dependency (200301-04) • The difference between both models is generally lower than 10% for all scenarios. • Highest differences are found in the lowest stratosphere below 20km. For higher SZAs we find differences (>10%) in the upper stratosphere.

  7. Validation results: O3 • Validation with ozone sondes (GAW-contributing ground-based networks, see D. Hubert, SCIAVALIG validation meeting 09/2010): On average the SGP 5.01 processor showed ~10% higher O3 density values than SGP 3.01. O3 profiles retrieved with SGP 5.01 are of equivalent or better quality than those retrieved with SGP 3.01. E.G. Ascension 8°S(+10%), Uccle 50°N(~0%), Belgrano 78°S (+5%) • Comparison with lidar, sonde and microwave 2002-2004 (VALID, see talk J.A.E. van Gijsel, SCIAVALIG validation meeting 09/2010): positive bias in the tropics (~12%), midlatitudes (~7%), negative bias in the polar region(~-8%).

  8. Summary O3 OP5.1 vs IUP 2.3 • The IUP ozone retrieval in V2.3 was finetuned to reduce the high bias found in the tropical regions. This leads to less ozone found in the midlatitudes and polar regions. • Comparisons with the OP5.1 shows on average 8% lower values of the IUP2.3. This differs slightly for different latitude and sun zenith angle regions between 6 and 10%. • Highest differences above 10% were found in the upper stratosphere at high SZA and near the troposphere. • Comparing these results with the validation datasets: • Tropics: OP5.1 ~10% higher -> IUP2.3 more accurate as expected • Midlatitudes: “inconsistent” validation data: OP5.1 ~7% higher -> IUP2.3 possibly nearer to validation results • Polars: “inconsistent” validation data: OP5.1 +/-6% -> low bias of IUP2.3 can be expexted

  9. Limb NO2: OP3/4 (from PM4) and OP5.1 OP5.01: comparison with IUP V3.1 (200301-04) • The OP5.1 NO2 gives basically the same results as OP4, which is as expected.

  10. NO2: Summary • Differences between two retrievals of the OP5.1 and the IUP 3.1 are generally below 10% for the height range of 21 and 38 km. • Highest differences above 20% were found for high SZAs in the upper stratosphere and lowest stratosphere.

  11. Limb BrO: all data 2003 (01—04) • On average the differences between the BrO OP5.1 and IUP3.2 are below 10% between 20 and 30 km, but the scatter is 50% and more. These results are as expected.

  12. BrO: time dependent differences 200304 201004 • Comparing data from 2003 and 2010: • The differences between both models are slightly increasing. • The scatter drastically increases.

  13. BrO: Summary of results • On average both models OP5.1 and IUP3.2 give similar results. • The differences and the scatter found are higher in 2010 than in 2003. • The differences also depend on altitude, latitude, and SZA: • Polar NH: OP5.1 -15% (01/03) -> -5% (04/03), similar in 2010 • Polar SH: OP5.1 +50% (01/03) -> +5% (04/03) • Tropics: OP5.1 -10% (30km) / +40%(20km), no change over time

  14. Limb cloud top height - Verification with MIPAS • Cloud top height between 9.0-25.0 km • Max. Difference in distance=300 km and seconds=990 sec. • SCIAMACHY - MIPAS [km]: 200902 • 3382 Diff= -0.9 (1.9) • 30 N >50 Mean=12.0 Diff=1.4 (2.0) • 542 N 15/50 Mean=12.4 Diff:-0.7 (1.7) • 2047 T Mean=14.9 Diff=-1.30 (1.7) • 762 S -15/-50 Mean=14.1 Diff=-0.0 (2.0) • SCIAMACHY - MIPAS [km]: 200906 • 3722 Diff=-1.2 (1.5) • 57 N >50 Mean=12.3 Diff=0.4 (2.0) • 1147 N 15/50 Mean=13.6 Diff=-1.0 (1.6) • 2051 T Mean=14.4 Diff=-1.4 (1.4) • 459 S -15/-50 Mean=12.6 Diff=-0.7 (1.3) • 8 S <-50 Mean=11.8 Diff=-0.8 (0.8) • The comparison with MIPAS done for CTH above 9 km gives good results. The mean height is between 12 and 15km. The mean difference is on the order of -1 km. • Below about 9 km MIPAS has very low sensitivity.

More Related