ZOLL Medical Corporation Sales Training

M Series Agenda. MonitorDefibrillatorClinically superior biphasic technologyExternal PacingClinically superior pacing technologySolutions for Customer Goals. M Series Overview. The Fuel Behind the FireCompare ZOLL's growth to the launch of the M Series

lotus
Télécharger la présentation

ZOLL Medical Corporation Sales Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. ZOLL Medical Corporation Sales Training Today when we think about the purchase of defibrillators, we find ourselves asking different questions. A few years ago, we assigned a lot of importance to factors such as its size and weight. While they are still important, we now need to consider things such as biphasic technology, early defibrillation, and JCAH O compliance.Today when we think about the purchase of defibrillators, we find ourselves asking different questions. A few years ago, we assigned a lot of importance to factors such as its size and weight. While they are still important, we now need to consider things such as biphasic technology, early defibrillation, and JCAH O compliance.

    2. M Series Agenda Monitor Defibrillator Clinically superior biphasic technology External Pacing Clinically superior pacing technology Solutions for Customer Goals VERY IMPORTANT- TIE THIS TO KNOWLEDGE OF AHA AND ASKING THE PROPER QUESTIONS TO UNCOVER TRANSPORT NEEDS (CCT) VERY IMPORTANT- TIE THIS TO KNOWLEDGE OF AHA AND ASKING THE PROPER QUESTIONS TO UNCOVER TRANSPORT NEEDS (CCT)

    3. M Series Overview The Fuel Behind the Fire Compare ZOLLs growth to the launch of the M Series.. Smaller Lighter Brighter Better Superior biphasic waveform Superior pacing waveform Easy Intuitive Uniform Operating System Dynamic Error Correction Configurable Upgradeable

    4. ZOLL M Series Monitor

    5. M Series Monitor KNOWLEDGE Basic ECG Monitoring: Attach electrodes Select MONITOR Press LEAD button to get desired lead Press SIZE button to get desired size

    6. M Series Monitor KNOWLEDGE 5-Lead Monitoring: Disconnect 3-lead cable Connect 5-lead cable Attach electrodes Select MONITOR Press LEAD button to get desired lead Press SIZE button to get desired size Printing 3 leads - Set configuration: PRINT 3 LEADS WHEN LEADS ARE SEL = YES

    7. M Series Monitor KNOWLEDGE Recorder: Start: Press RECORDER Stop: Press RECORDER Note there is always a 6 second delay Strips include: Date & Time ECG Lead Size Heart Rate

    8. M Series Monitor KNOWLEDGE Vital Signs Trending HR, SpO2, EtCO2, Respiration Rate, Systolic BP, Diastolic BP, Mean BP Trending = ENABLED in Configuration Data sampled 1/minute for max 24 hrs, plus with any alarm, and with any NIBP measurement

    9. M Series Monitor KNOWLEDGE Viewing Vital Signs Trends Press SUMMARY Press TREND Press SELECT to highlight SET TRACE 2 or SET TRACE 3 Press ZOOM to change the interval period: All, 60 min, 30 min, 15 min, 10 min, 5 min To print report, press PRINT on trend screen

    10. M Series Monitor KNOWLEDGE

    11. M Series Monitor KNOWLEDGE Clearing Vital Signs Trends Press & hold SUMMARY Erase Summary, Erase Trend, Erase All is displayed Press ERASE TREND

    12. M Series Monitor UNDERSTANDING Practice Monitor In-Service

    13. M Series Monitor UNDERSTANDING Key Differentiators/Key Selling Points: Uniform operating system Benefit: Increases operator confidence and reduces training costs by utilizing same user interface in all generations of product and in every model of the M Series platform Question: Have you ever had a situation where youve arrived at an arrest and the equipment is unfamiliar? Question: How often are you trained on equipment? Question: Would it be beneficial to have your crash cart devices work the same as your transport devices? Error correcting messages Benefit: Audibly and visually suggests corrective action (ie. Attach ECG Lead vs ECG Lead Off) Question: How does your equipment currently notify you of problems?

    14. M Series Monitor UNDERSTANDING Key Differentiators/Key Selling Points: Intuitive design Benefit: Put an M Series in front of a clinician, and theyll be able to use it with very little training Question: Have you ever been confused about how to operate a piece of equipment? Question; How often have equipment challenges prevented you from treating a patient in a timely manner? Large, bright LED display Benefit: Ability to see screen from every angle Question: What do you currently do to see your screen when youre standing to the side / at an angle?

    15. M Series Monitor APPLICATION Practice Monitor Demo

    16. M Series Monitor APPLICATION Customer Goals ZOLL Solutions

    17. ZOLL M Series Defibrillator

    18. M Series Defibrillate Catherine Prophet April 2005

    19. M Series Defibrillation KNOWLEDGE Manual Defibrillation Attach MFE Electrodes to patient Recommend ZOLL electrodes customized for optimal performance with ZOLL M Series Select DEFIB Unit automatically defaults to first shock setting determined in Configuration (typically 120J, 150J, 200J) To change energy setting, use UP/DOWN ARROWS. Selected energy is displayed as DEFIB XXXJ SEL Press CHARGE Make sure everyone is clear When SHOCK button lights, press SHOCK If so configured, the M Series automatically increments the energy setting after the first shock according to configuration. Manually changing the energy setting disables this function. Note: Changing the energy level or switching to MONITOR after CHARGE is pressed results in defibrillator being disarmed

    20. M Series Defibrillation KNOWLEDGE Manual Defibrillation with Paddles Select DEFIB Unit automatically defaults to first shock setting determined in Configuration (typically 120J, 150J, 200J) To change energy setting, use UP/DOWN ARROWS Press CHARGE on the panel or on the apex handle Apply electrolyte gel to the paddles and apply paddles to chest Make sure everyone is clear When SHOCK button lights, place paddles on chest with 25 lb pressure and simultaneously press SHOCK on both paddles Note: Changing the energy level or switching to MONITOR after CHARGE is pressed results in defibrillator being disarmed

    21. M Series Defibrillation KNOWLEDGE Advisory Defibrillation Attach MFE Electrodes to patient Select DEFIB Press ANALYZE. ANALYZING ECG will be displayed for about 9 seconds. If unit displays SHOCK ADVISED, defibrillator automatically charges to first shock setting determined in Configuration (typically 120J, 150J, 200J) If automatic charge is disabled, SHOCK ADVISED and PRESS CHARGE will be alternately displayed. To change energy setting, use UP/DOWN ARROWS. Selected energy is displayed as DEFIB XXXJ SEL Make sure everyone is clear When SHOCK button lights, press SHOCK If so configured, the M Series automatically increments the energy setting after the first shock according to configuration. Manually changing the energy setting disables this function. Note: Changing the energy level or switching to MONITOR after CHARGE is pressed results in defibrillator being disarmed EMPHASIZE HERE THAT THE CUSTOMER CAN CHOOSE DO YOU WANT THE FIRST RESPONDER TO PUSH A BUTTON TO BEGIN ADVISORY (ADVISORY/ACLS MODEL) OR DO YOU PREFER THAT THE ACLS PROVIDER PUSH THE BUTTON WHEN THEY ARRIVE?(UNIV ERSAL /BLS AED) MANY NEW TMS DO NOT GRASP THE DIFFERENCE BETWEEN THE MODELS ENOUGH TO EXPLAIN THEM. EMPHASIZE HERE THAT THE CUSTOMER CAN CHOOSE DO YOU WANT THE FIRST RESPONDER TO PUSH A BUTTON TO BEGIN ADVISORY (ADVISORY/ACLS MODEL) OR DO YOU PREFER THAT THE ACLS PROVIDER PUSH THE BUTTON WHEN THEY ARRIVE?(UNIV ERSAL /BLS AED) MANY NEW TMS DO NOT GRASP THE DIFFERENCE BETWEEN THE MODELS ENOUGH TO EXPLAIN THEM.

    22. M Series Defibrillation KNOWLEDGE Automatic Defibrillation (AED) Attach MFE Electrodes to patient Turn unit ON Unit automatically defaults to first shock setting determined in Configuration (typically 120J, 150J, 200J) To change energy setting, use UP/DOWN ARROWS. Selected energy is displayed as DEFIB XXXJ SEL Press CHARGE Make sure everyone is clear When SHOCK button lights, press SHOCK If so configured, the M Series automatically increments the energy setting after the first shock according to configuration. Manually changing the energy setting disables this function. Note: Changing the energy level or switching to MONITOR after CHARGE is pressed results in defibrillator being disarmed

    23. M Series Defibrillation KNOWLEDGE Synchronized Cardioversion Press LEAD to select desired ECG lead Select DEFIB Select desired energy level Press SYNC softkey. Verify presence of SYNC marker ? Press CHARGE Verify everyone is clear of patient Press SHOCK Note: Use of ZOLL electrodes is strongly recommended. Clinical results for AF cardioversion are based on 3 part system: ZOLL Biphasic Waveform, ZOLL electrodes & pad placement EXPLAIN WHAT THE MACHINE IS DOING AND WHY SYNC VS. DEFIB. EXPLAIN THE CONSEQUENCES IF THE CLINICIAN DOES NOT PUSH SYNC. EXPLAIN WHY THE MACHINE CONVERTS BACK TO DEFIB AFTER EACH SHOCK AND WHY WE WANT IT THAT WAY. EXPLAIN THIS IS STILL A VERY EFFECTIVE MEANS INTO A HOSPITAL TO SELL DEFIBS. EXPLAIN WHAT THE MACHINE IS DOING AND WHY SYNC VS. DEFIB. EXPLAIN THE CONSEQUENCES IF THE CLINICIAN DOES NOT PUSH SYNC. EXPLAIN WHY THE MACHINE CONVERTS BACK TO DEFIB AFTER EACH SHOCK AND WHY WE WANT IT THAT WAY. EXPLAIN THIS IS STILL A VERY EFFECTIVE MEANS INTO A HOSPITAL TO SELL DEFIBS.

    24. M Series Defibrillation KNOWLEDGE Code Markers Pressing CODE MARKER softkey during defibrillation displays the following options: CPR B-block Fentanyl Intubate Atrovent Digoxin EPI Mag Sulf Vasopr LIDO Procain Narcan Adenosin Pressing the softkey for a specific code marker will cause that action to be recorded along with a date and time stamp in the Summary Report Memory

    25. M Series Defibrillation KNOWLEDGE Printing Reports Summary Report triggered by six events: VF Alarm HR Alarm Defibrillator Shock Turn Recorder ON Selecting PACER Pressing ANALYZE Memory stores up to 65 defibrillation or 140 recorder activated ECG events Press SUMMARY to print report, then select softkey: Print Config: Configuration settings Print Chart: Select from All or Range of Events Print Log: Incident log To add patient name and ID, press ID# softkey and enter information

    26. M Series Defibrillation KNOWLEDGE Biphasic Waveform Fixed & Flat design Fixed duration, constant current Current defibrillates ZOLL has the most Only biphasic waveform cleared by the FDA to be labeled superior to monophasic for cardioversion of AF & defibrillation of high impedance VF Controls for variations in patient impedance through series of digital equipment resistors so that the low impedance patient is not overdosed and the high impedance patient gets the most current of any defibrillator Defibrillation protocol: 120J 150J 200J Cardioversion protocol: 75J 120J 150J 200J

    27. M Series Defibrillation KNOWLEDGE ZOLL Multifunction Electrodes Always mention electrodes during defib product overviews and in-services Validated as part of the system high quality performance guaranteed Question: Do you want to use electrodes not validated and proven on your defib system? Not all have equivalent performance. Critical success factor for biphasic in clinical studies biphasic electrode and proper pad placement Optimized product line for resuscitation and therapy statpadz speed pack, center energy feed Question: Do you want to lose precious response time by using pads without a preconnect feature on your defibrillator? propadz liquid gel and specialized electrodes Question: Would you like to reduce the risk of dermal damage? Do you have needs for radiolucent or sterile electrodes in your OR and Cath/EP labs? pedipadz liquid gel reduces dermal damage Question: Would you like to offer your pedi patients the best care for their delicate skin? CPR-Dpadz one piece, CPR feedback ZOLL only defib company to own electrode manufacturing control over quality, innovation, service and inventory Question: Third party branded electrodes my save pennies, but why risk integrity of life saving therapy? Best reputation in the industry No need for adaptors or special connectors

    28. M Series Defibrillation UNDERSTANDING Practice Defibrillation In-Service GOOD AND ALSO EXPLAIN THE POTENTIAL PITFALLS EX. MFC NOT PLUGGED IN TO PADDLES, MFC IN PADDLES BUT NURSE DOES NOT KNOW THIS ETC GOOD AND ALSO EXPLAIN THE POTENTIAL PITFALLS EX. MFC NOT PLUGGED IN TO PADDLES, MFC IN PADDLES BUT NURSE DOES NOT KNOW THIS ETC

    29. M Series Defibrillation UNDERSTANDING Key Differentiators/Key Selling Points Clinical superiority with rectilinear biphasic technology Benefit: Better patient outcomes and reduced costs through increased efficacy of rectilinear biphasic waveform Question: What have your experiences been with defibrillation during a code/cardioversion? How many times do you typically have to shock a patient? Low Energy Defibrillation Benefit: Provides the ability to use lowest effective dose of therapy for defibrillation and cardioversion Question: Are you aware of the AHAs statements on biphasic defibrillation? Question: Are you aware of the Mittal AF or VF studies on the rectilinear biphasic waveform? AED, Advisory or Manual on the same platform Benefit: One machine can be used for various clinical applications throughout the hospital Question: Are you familiar with AHA Guidelines regarding code response time? Question: Describe what happens when you have a code called on a Med/Surg floor? Configurable Auto-escalation Benefit: Eliminates one step in an already hectic environment and reduces the necessity to remember new energy protocols Question: What is your current procedure for energy escalation? Uniform Operating System Error correcting messages Large, bright LED display

    30. M Series Defibrillation APPLICATION Practice Defibrillation Demo

    31. M Series Defibrillation APPLICATION Customer Goals ZOLL Solutions MIGHT ADD SOMETHING FOR PRODUCT MIX OR VARIOUS MODELS FOR THE SOLUTION TO REPONSE TIMES. ANOTHER HOSPTAL GOAL IS COST EFFECTIVE CARE WITH THE SOLUTION OF GREATER EFFICACY MEANING LESS COST, STANDARDIZATION OF OPERATING SYSTEM LOWERS TRAINING COST, PRODUCT MIX OFFERS ONE MANUFACTURER FOR VARIOUS DEPTS. Ie CCU, MEDSURG, EP AND OUTSIDE BUILDINGS. YOU GET THE POINT MIGHT ADD SOMETHING FOR PRODUCT MIX OR VARIOUS MODELS FOR THE SOLUTION TO REPONSE TIMES. ANOTHER HOSPTAL GOAL IS COST EFFECTIVE CARE WITH THE SOLUTION OF GREATER EFFICACY MEANING LESS COST, STANDARDIZATION OF OPERATING SYSTEM LOWERS TRAINING COST, PRODUCT MIX OFFERS ONE MANUFACTURER FOR VARIOUS DEPTS. Ie CCU, MEDSURG, EP AND OUTSIDE BUILDINGS. YOU GET THE POINT

    32. ZOLL M Series External Pacing

    33. M Series Pace Catherine Prophet April 2005

    34. M Series Pacing KNOWLEDGE Value of External Pacing 60% of codes do not require defibrillation Survival rates for non-VT/VF rhythms is less than 10%

    35. M Series Pacing KNOWLEDGE External Pacing Apply electrodes and ZOLL MFE pads Select PACER Turn PACER RATE knob clockwise to set rate 10-20 ppm higher than intrinsic rate or 100 ppm Turn PACER OUTPUT knob clockwise to increase mA until capture Press and hold 4:1 button to deliver pacing impulse for 1 out of 4 beat to determine underlying rhythm

    36. M Series Pacing KNOWLEDGE Pacing Pad Placement Apply EKG electrodes Identify your Heart Rate Pad Placement: Back Pad First between scapula & spine Front Pad V2-V5 Take pulse on the right side Apply Back Pad First Dont shave patient

    37. M Series Pacing UNDERSTANDING Practice Pacing In-Service

    38. M Series Pacing UNDERSTANDING

    39. M Series Pacing UNDERSTANDING NTP 1000: 1983 Marketed in 1983 Pacemaker/Monitor Price $7200 Always sold at list Never did evaluations Pacing Electrodes only

    40. M Series Pacing UNDERSTANDING ACLS Guidelines 2000 Transcutaneous pacing is a Class I intervention for all symptomatic bradycardias. If clinicians are concerned about the use of atropine in higher level blocks, they should remember TP is always appropriate..If the bradycardia is severe and the clinical condition is unstable, implement TP immediately p.I-155

    41. M Series Pacing UNDERSTANDING LARGER SURFACE AREA ELECTRODES CONSTANT CURRENT-RECTILINEAR WAVEFORM HIGH IMPEDENCE GEL LONG PULSE DURATION-UP TO 40 MS

    42. M Series Pacing UNDERSTANDING Different Pacing Waveforms: ZOLL- Rectilinear Physio- Truncated Exponential Philips- Truncated Exponential

    43. M Series Pacing UNDERSTANDING

    44. M Series Pacing UNDERSTANDING

    45. M Series Pacing UNDERSTANDING Key Differentiators/Key Selling Points Clinically superior pacing waveform Twice the rate of capture Benefit: Potential for higher survival rates Question: What do you do when there is not shock advised? What are your criteria for using external pacing? What has your experience been with external pacing? Question: What is your understanding of the differences between pacing technologies? Question: Where might your approach change if you could capture more patients? Half the current for capture Benefit: Ability to maintain external pacing at a comfortable level for longer periods of time Question: How might capturing at lower energy levels benefit the patient? High efficacy with $35 pads Benefit: Cheaper to than floating internal wires Question: When do you float wires to establish internal pacing? Uniform operating system Error correcting messages Large, bright LED display

    46. M Series Pacing APPLICATION Practice Pacing Demo

    47. M Series Pacing APPLICATION Customer Goals ZOLL Solutions

    48. Selling Pacing: Who to talk to What to say

    49. ZOLL M Series: Putting it All Together

    50. User Goal

    51. M Series Offers Solutions

    52. M Series Offers Solutions

    53. M Series Offers Solutions Driven by design principles of cockpit safety. Issues corrective prompt instead of describing error: ECG LEAD OFF

    54. User Goal With public attention on AEDs, expectations, With public attention on AEDs, expectations,

    55. M Series Offers Solutions

    56. User Goal

    57. M Series Offers Solutions

    58. M Series Offers Solutions

    59. User Goal

    60. M Series Offers Solutions

    61. User Goal

    62. M Series Offers Solutions

    63. User Goal

    64. Customer-Driven Success Driven by unmatched focus on customer needs Ranked 11th on Forbes listing of 100 Fastest Growing Small Companies Fastest growing hospital defibrillator company Growth driven by customers switch to ZOLL from other suppliers

    65. Top 15 Cardiac Hospitals All Use ZOLL

    66. M Series Configuration Critical Questions? Review configuration options on your own

    67. M Series Summary Standardization: Tools for everyone in every environment Consistency that Builds Confidence: Uniform operating system & Dynamic error correction Superior clinical results with patented biphasic and pacing waveforms Upgradeable to adapt to changing needs over time ZOLL = partner focused on resuscitation