1 / 33

This is a special venue for me!

This is a special venue for me!. Time Domain Astronomy: The Next Decade. S. R. Kulkarni Caltech Optical Observatories. Major division: Variable objects & Transients. Variable Objects. Key measurement: Light Curves Photometric Precision Low: RR Lyrae , Cepheids , AGN, Type Ia

louise
Télécharger la présentation

This is a special venue for me!

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. This is a special venue for me! 32

  2. 32

  3. Time Domain Astronomy: The Next Decade S. R. Kulkarni Caltech Optical Observatories

  4. Major division: Variable objects & Transients 32

  5. Variable Objects • Key measurement: Light Curves • Photometric Precision • Low: RR Lyrae, Cepheids, AGN, Type Ia • Moderate: Eclipsing Binaries, Gravitational Lensing • High: Planetary Transits, Asteroseismology • What is of value? • Total number of visits usually matters more than cadence • Spectroscopy (followup) • In most cases rapid follow up is not essential • In many cases spectroscopy helps but is not crucial 32

  6. Transient Objects • Imaging surveys provide the starting point for investigation • Supernova investigations are triggered by detection of a rising object • For many studies the follow up is decoupled from the initial detection of a GRB (at high energies) • Cadence control is critical • On the first night of an imaging survey the detected transients are dominated by old supernovae • Conversely lack of cadence control presents significant opportunity costs (negative) • Cadence directly determines the phase space that is being explored • “Universal” cadence simply means that everyone is equally unhappy 32

  7. This Talk • Focused entirely on transient object astronomy • Main thesis: • Transient object astronomy is served best by sharply focused time domain surveys • Conversely, the returns from a generic time domain survey are likely to be quite poor (and wasteful of follow up resources) • Transient Object Astronomy has a bright future in this decade and likely to continue into the next decade (when TMT will become operational) • However, TMT time is precious • Transient object astronomy has its own learning curve • The TMT collaboration must start preparing now 32

  8. An exemplar 32

  9. The IntermediatePalomar Transient Facility (iPTF)

  10. The Palomar Observatory P60 P48 P200 32

  11. P60 Confirmation P48 Discovery P200 Spectroscopy 32

  12. Kasliwal 2011 (PhDT) 32

  13. Super-luminous Supernovae (no Hydrogen) 32

  14. Death Omen! PTF10tel 32

  15. Double degenerates: The new frontier 32 Source: LISA Mission, NASA

  16. On to low latency(Same night) 32

  17. PTF11kly: A nearby Ia Explosion(Rosetta Stone) 32

  18. Progenitor of a Ib Supernova! 32

  19. What next? S. R. Kulkarni

  20. Short timescale is terra incognito 32

  21. PTF11agg: Dirty Fireball? 32

  22. Same night arcsecond localization of error region of 72 square degrees! 32

  23. As we go to press! GRB131011A M. Kasliwal L. Singer 32

  24. TITLE:   GCN CIRCULARNUMBER:  15324SUBJECT: Fermi403206457: iPTF detection of a possible optical afterglowDATE:    13/10/12 12:09:55 GMTFROM:    Mansi M. Kasliwal at Caltech/Carnegie  <mansikasliwal@gmail.com>M. M. Kasliwal (Carnegie Observatories/Princeton),  L. P. Singer (Caltech) and S. B. Cenko (NASA/GSFC) report on behalf of the intermediate PalomarTransient Factory (iPTF) collaboration:Starting 2013-10-12 05:26 UT, we imaged about 70 deg^2 in the vicinity of the localization of the Fermi-GBM trigger 403206457 with the Palomar 48-inch Oschin telescope (P48). Sifting through 10,816 candidate variable sources in the GBM error circle using standard iPTF vetting procedures including Palomar 60-inch follow-up, we identify iPTF13dsw as a possibleoptical afterglow candidate:   RA(J2000)  =  02h 10m 06.38s  DEC(J2000) = -04d 24' 40.3"  Light Curve: R=19.7mag @ 05:26 UT (P48), R=20.2mag @ 08:07 UT (P60)iPTF13dsw is 3.4 deg away from the center of the final GBM localization(68% statistical confidence radius of 2.75 deg). Nothing was detected atthis location to a limiting magnitude of 20.6 mag on 2013 Sep 25.At 08:56 UT, we obtained a Gemini-South/GMOS spectrum in twilight. Thespectrum is mostly featureless, with no prominent emission or absorptionlines between 5100-9300A.. 32

  25. what is the metric of synoptic surveys? 32

  26. Proposed Metrics • The “Reach” Etendue, AΔΩ • Point source sensitivity, AΔΩ/θ2 • These metrics make sense only for static surveys. • Not relevant for transient surveys • For transients mere detection in itself is limited value • Classification and follow up is the key 32

  27. Fundamental Parameters of a Time Domain Survey (Transients) • Field-of-view (FOV), ΔΣ • Sensitivity (6σ), Sl • Time to move one FOV, τm • Cadence: typical time separation between re-visit to the same FOV • Basic Integration time, τs(frame time) • Assume 60-s for all surveys 32

  28. Areal Rate • Short Duration Transients (T<τs) • Long Duration Transients (T>τs) • If follow up is essential then all that matters is Sl(set by follow up) and the parameters shown above. For 21-mag ZTF is 250 times faster than say HSC. 32

  29. Zwicky Transient Facility

  30. 47-sq degree camera for P48 32

  31. The SED Machine for P60 30 arcsec 7 arcminute PI: Nick Konidaris, PS: Robert Quimby In collaboration with NCU-Taiwan 32

  32. A Proposal: TMT Community based Transient Object Facilities • Recognizing that transient object astronomy is a growing field with great promise the TMT community should ensure that it has access to quality transients • Transient searches have three fundamental parameters and as such the idea that a single facility (equipped with “Universal Cadence”) can provide the transient stream is incorrect • The preparation for this should start now so that the event streams will be ready by 2022. 32

  33. ZTF Annual Workshops • The ZTF consortium will be holding yearly meetings (along the lines of the very successful iPTF 2013 Workshop) • We plan to invite key players from TMT consortium to attend these meetings • http://ptf.caltech.edu/iptf/iptf_workshop/ 32

More Related