1 / 27

VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS

This module provides visual aids for understanding the indirect measurement of pressure using properties of gases in vacuum technology and applications. It covers the fundamentals of heat transfer, thermal interactions, and heat transfer mechanisms in different pressure ranges. It also introduces thermal manometers and discusses thermocouple gauges and Pirani gauges.

louisep
Télécharger la présentation

VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS Second Edition Module 2: Total Pressure Measurement in Vacuum Section 3 Indirect Measurement of Pressure I Gauges Using Properties of the Gas

  2. The gauges described in this Chapter use bulk properties of gases as a measure of pressure Indirect Measurement of Pressure • Clearly, such properties have to be pressure dependent to form the basis of a gauge • Suitable properties are heat transfer or viscosity • We first consider some fundamentals of heat transfer

  3. Often when we think about the behaviour of gas molecules in a vacuum system, we assume the system to be in equilibrium, with the gas molecules having a Maxwellian energy distribution Indirect Measurement of Pressure Thermal Interactions • For this to apply, the system has to be at a uniform temperature • In this case, when a gas molecule strikes a surface, it stays on the surface for a relatively long period of time so that when it leaves the surface again, it has no memory of the direction from which it arrived • On average, gas molecules will leave the surface with the same average energy with which they arrived - i.e. at the same temperature • This is described as complete accommodation • Gas molecules will leave the surface with a cosinevelocity distribution

  4. When different parts of the vacuum system are at different temperatures, the temperature of a gas molecule may, on average, be different from the temperature of a surface which it strikes Indirect Measurement of Pressure Thermal Interactions • The velocity distribution of gas molecules leaving the surface may not be a simple cosine • Under these circumstances, thermal transfer (i.e. energy transfer) can occur between surfaces • The process can be described by an accommodation coefficient  1 • The value of  will depend on the gas concerned and the surface involved

  5. Indirect Measurement of Pressure Thermal Interactions Here, the gas atom or molecule coming in from the left has an energy equivalent to a temperature of Ti. When it strikes the surface which is at the higher temperature Ts, the gas atom can gain some kinetic energy and leave with a temperature equivalent to Tr

  6. Indirect Measurement of Pressure Thermal Interactions Here, a gas molecule is scattered between two surfaces at different temperatures T1 and T2 At point 1, it undergoes an elastic scattering from the lower surface at temperature T2 It is then, at point 2, adsorbed onto the upper surface at temperature T1

  7. Indirect Measurement of Pressure Thermal Interactions It leaves this surface having gained energy and is adsorbed onto the lower surface at point 3 As T1>T2, the molecule gives up some energy to the surface before leaving at an intermediate temperature T3 The net effect is transfer of energy (heat) from the upper to the lower surface The overall accommodation coefficient  is as shown

  8. Indirect Measurement of Pressure Thermal Interactions This table shows some values of accommodation coefficients for a range of gas species and surfaces

  9. Heat transfer from a hot to a cold surface can occur through two basic mechanisms dependent on the pressure of the gas, or more accurately on the mean free path of the gas molecules in the gas. Indirect Measurement of Pressure Heat Transfer • Where the mean free path is less than the dimensions of the gauge, then gas flow is viscous and the main mechanism of heat transfer is by convection • Where the mean free path is greater than the dimensions of the gauge, then gas flow is molecular and the main mechanism of heat transfer is by conduction • There is also a pressure independent transfer of heat by radiation • These processes are illustrated in the next two slides

  10. Indirect Measurement of Pressure Heat Transfer This figure shows the various energy flows for a system whose configuration is typical for a thermal manometer

  11. Indirect Measurement of Pressure Heat Transfer We can see here the net energy transfer as a function of pressure. At high pressures (Region III) the energy flow is almost independent of pressure as is the case at low pressures. In Region II it is a strong almost linear function of pressure. In Region 1 it is a less strong, but still useful function.

  12. Thermal manometers are devices in which heat transfer away from a hot wire in vacuum is measured to provide an analogue of pressure Indirect Measurement of Pressure Thermal Manometers • The wire – often referred to as the filament – is usually heated by passing an electric current through it • The temperature of the filament may be measured directly, either with a thermocouple or a thermistor • Alternatively the power transferred from the filament to its surroundings may be measured electrically • In all such devices, the gauge sensitivity is dependent on the gas species being measured • We will illustrate thermal transfer gauges shortly by looking at Thermocouple gauges and Pirani gauges

  13. Indirect Measurement of Pressure Thermal Manometers This is a typical set of relative sensitivities, , for a typical thermal manometer for some common gases The sensitivities are relative to air (or nitrogen) The precise ratios will depend on the actual gauge used

  14. Indirect Measurement of Pressure The Thermocouple Gauge The simplicity of such a gauge can be seen here – a thermocouple is simply spot welded to the centre of the heated filament and the potential developed measured on the millivoltmeter A thermistor may also be used and its resistance measured

  15. Indirect Measurement of Pressure The Thermocouple Gauge The sensitivity of such a gauge (expressed here as millivolts) as a function of pressure is now shown Again, the sensitivity is dependent on the gas species being measured

  16. In a Pirani gauge, the filament (heated wire) forms one arm of an electrical bridge circuit Indirect Measurement of Pressure The Pirani Gauge Here we can see the basic construction of the Pirani gauge head and a schematic of the external electrical bridge circuit

  17. The Pirani gauge can be operated in one of two modes Indirect Measurement of Pressure The Pirani Gauge • a constant voltage is applied across the filament. The resistance will therefore vary as the temperature varies due to the varying heat transfer and the imbalance current of the bridge will be an indication of the pressure • the input voltage to the bridge is varied such that the bridge is always balanced with the filament maintained at a constant temperature i.e. the filament is maintained at a constant resistance. The voltage across the bridge is a measure of the pressure

  18. Indirect Measurement of Pressure The Pirani Gauge Here we can see how the sensitivity of a Pirani gauge varies with pressure and gas species

  19. Indirect Measurement of Pressure The Pirani Gauge Here we see in more detail a set of calibration curves for a Pirani gauge operated in constant filament temperature mode for a range of gases The curves are the sensitivities of the gauge relative to nitrogen

  20. Indirect Measurement of Pressure The Pirani Gauge The details of such a set of curves will depend on the exact gauge used, but the trends shown here will be typical Note the great divergence of behaviour exhibited at higher pressures for the different gases where convection is important

  21. Indirect Measurement of Pressure The Pirani Gauge These are typical scales found on analogue meters for both the constant voltage and constant resistance (constant temperature) types of Pirani gauges The constant resistance type is seen to operate over a wider pressure range. Many modern Pirani gauge electronics will use a digital display so such differences will not be so immediately obvious

  22. Thermocouple gauges operate between about 103 Pa and 0.1 Pa Indirect Measurement of Pressure Thermal Manometer Accuracy • These are not high accuracy gauges and contamination of the filament can cause serious shifts in sensitivity • Pirani gauges operate between about 104 Pa and 0.1 Pa • Again they are not high accuracy gauges, but clean gauges can exhibit short term reproducibility of the order of 10% • Any thermal gauge will have a relatively long time constant

  23. Modern developments in Pirani gauges have led to solid state sensors being developed Indirect Measurement of Pressure Modern Developments • These sensors use the well known techniques developed for manufacturing integrated electronic circuits • The sensor is manufactured directly on silicon • An example is shown in the next slide

  24. Indirect Measurement of Pressure Solid State Pirani Sensor Construction of the sensor Cross section of the sensor

  25. A gauge which uses a different gas property, viscosity, is the spinning rotor gauge Indirect Measurement of Pressure The Spinning Rotor Gauge • Here a steel ball is set spinning and its deceleration measured • The higher the pressure, the greater the viscous drag on the ball and the greater the deceleration experienced • The rotation of the ball – which has a small magnetic moment – is sensed by a pickup coil • The sensitivity of the gauge is relatively independent of gas species and is very stable - the uncertainty is better that 3% and stability better than 2% per annum • The operating pressure range is 1 Pa to 10-4 Pa • The gauge can be used as a transfer standard for calibration

  26. Indirect Measurement of Pressure The Spinning Rotor Gauge This is a typical example of such a gauge The vacuum tube or thimble in which the spinning sphere is situated is often made of glass To give an idea of size, the vacuum flange is 70mm in diameter

  27. VISUAL AIDS for instruction in VACUUM TECHNOLOGY AND APPLICATIONS Module 2: Total Pressure Measurement in Vacuum Second Edition End of Section 3 Indirect Measurement of Pressure I Gauges Using Properties of the Gas

More Related