Demolition 29 CFR 1926, Subpart T

Demolition 29 CFR 1926, Subpart T. Overview of the OSHA regulation . Preparations Pre-job survey By competent person Determine structural integrity Have evidence in writing. 1a. Overview of the OSHA regulation . Preparations All utilities shut off

lynley
Télécharger la présentation

Demolition 29 CFR 1926, Subpart T

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Demolition29 CFR 1926, Subpart T

  2. Overview of the OSHA regulation • Preparations • Pre-job survey • By competent person • Determine structural integrity • Have evidence in writing 1a

  3. Overview of the OSHA regulation • Preparations • All utilities shut off • Needed utilities relocated to temporary hook-up • Identify hazards & guard (glass) • Cover all floor openings not to be used 1a

  4. Stairs, Passageways, & Ladders • Close those not to be used • Maintain only those for access • Proper illumination needed 2a

  5. Chutes • No dropping of materials outside the building w/o protection (chute) • Totally enclose chutes 45 degrees & greater • End of chute guarded 2b

  6. Masonry Removal • Do not overload floors with materials from other floors or components • Totally enclose chutes 45 degrees & greater • Safe access to scaffolds & walkways required 2b

  7. Floor Removal • Provide adequate work surfaces for employees • Minimum 2X10 (undressed) planks • Openings less than 16” 3a

  8. Using Equipment for Removal • Check structure’s ability to support load • Provide curbs to prevent driving over edge • Meet all aspects of Subparts N & O 3b

  9. Storage • Debris on floors must not exceed allowable floor loads 3c

  10. Mechanical Demolition • Keep employees out of work area • Remove heavy building attachments prior to demo • Cut steel prior to pulling over • Competent person must oversee job 3d