An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. API Spacer Wettability Tests May 30th – June 10th , 2013 Mud-Spacer Compatibility Test & Goniometer Contact Angle Test Wettability Test with Stirred Fluid Loss Apparatus SSST Test & Goniometer Contact Angle Test on Final Mixture SSST Test & Goniometer Contact Angle Test on Final Mixture (rerun)

  2. Spacer-Mud Compatibility Test & Goniometer Contact Angle Test * Goniometer won’t take measurement, contact angle was estimated to be 74 degree

  3. Stirred Fluid Loss Apparatus • Measure contact angle baseline on goniometer • Metal slide average contact angle = 73.02° • Glass slide average contact angle = 38.56° • Mud coated on both slide (Atmosphere Temp) • Spacer conditioned at 190° in stirred fluid loss apparatus • Glass slide became completely water wet • Metal slide had a average contact angle of 83.25°

  4. SSST – First Run

  5. Goniometer - Final SSST Mixture Treated • Wiped slides show lower contact angle (water-wet) compared with rinsed ones. • Glass slides coated with mud before dipping into SSST final mixture give a lower contact angle. To reinforce this observation, same test was rerun as shown in next page. • Metal slides didn’t show similar results as glass ones. Metal slide became more oil-wet after treated with mud.

  6. SSST – Rerun

  7. Goniometer - Final SSST Mixture Treated (Rerun) • New glass slides yield to a baseline around 30°, used glass slides cleaned by IPA and DI water yield to a base line around 43° • Wiped slides show lower contact angle (water-wet) compared with rinsed ones. • Glass slides coated with mud before dipping into SSST final mixture give a slightly lower contact angle, which repeats the result in previous test. However, glass slide coated with mud for 10 minutes gave a higher contact angle (oil-wet). Time duration of treatment may have a big effect on wettability result. • Tests can be run with metal slides are limited by the quantity of metal slides available in lab.