An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of the CARIOCA project Walter Bonivento CERN / INFN Cagliari for the LHCb collaboration and the CERN MIC group

  2. The LHCb muon detector LHCb muon detector: main task provide L0 trigger for b   X Five stations, M1 to M5; four radial regions, R1 to R4 R3-R4 of M4-M5 RPC 48% area rate cap. 1kHz/cm2 R1-R2 of M1 t.b.d. 1% area rate cap. 1MHz/cm2 the rest MWPC 52% area rate cap. 100kHz/cm2 W.Bonivento CERN/INFN Cagliari

  3. Readout electronicsfor MWPC:a) detector architecture Main performance requirement: efficiency in 20ns >99% 2 bi-gap logically OR-ed (DIALOG chip) 2mm gap, 1.5mm wire spacing wire, cathode and combined readout W.Bonivento CERN/INFN Cagliari

  4. Readout electronicsfor MWPC:b) requirements Detector signal: current with fast (ns) rise, fall Detector capacitance from 20pF to 200pF One threshold for time stamping: time resolution from slewing effect Optimum amplifier peaking time compromise between noise and slewing W.Bonivento CERN/INFN Cagliari

  5. Readout electronicsfor MWPC:b) requirements Optimum amplifier peaking time: about 10ns At large Cdet weak dependence of time resolution on peaking time To be able to set the threshold at about 6 p.e. Measurements on a prototype chamber performed with a hybrid from PNPI and a modified version of ASDQ chip (M.Newcomer-Penn) noise <2fC for Cdet 40-250pF At gas gain of 105 average 40fC for wires and 20fC for cathode range 150fC for 95% of the signals W.Bonivento CERN/INFN Cagliari

  6. Readout electronicsfor MWPC:b) requirements High rate: dead time pulse width <50ns unipolar and tail cancellation wire signals AC coupled with RLCdec= 100s baseline shifts baseline restoration Low cross-talk : Zin< 50  W.Bonivento CERN/INFN Cagliari

  7. CARIOCAProject overview 80k FE channels at 1Mrad dose in 10 years custom chip in radiation tolerant technology 0.25 m CMOS Final goal: differential structure Cancels 1/t tail Cancels preamp tail W.Bonivento CERN/INFN Cagliari

  8. CARIOCAProject overview PROTOTYPE CHIPS: step by step approach • 2000: positive preamp+current discriminator • +LVDS 4ch (1 analog ch.) • 2001: positive preamp+current discriminator • +LVDS 14ch W.Bonivento CERN/INFN Cagliari

  9. CARIOCAProject overview • 2001: negative preamp 8ch analog • 2001: positive preamp+shaper 4ch analog (diff. out.) • 2001: positive preamp+shaper+voltage discriminator+LVDS 4ch (diff. out.) • 2002: positive and negative full chain with baseline restorer (diff.out.) W.Bonivento CERN/INFN Cagliari

  10. The positive preamplifier:a) design Current amplifier NMOS with current mode feedback; unipolar Large input transistor W/L=1600m/0.7m Id=2mA at about 20MHz, the other two at 150MHz and 300MHz Dominant pole Followed by current discriminator (presented at LEB2000 by D.Moraes and replaced by a voltage discriminator in next version) +LVDS driver W.Bonivento CERN/INFN Cagliari

  11. The positive preamplifier:b) measurements Digital (S-curve)... ...and analog measurements Linearity Response to a delta Sensitivity: 8mV/fC (measurement) W.Bonivento CERN/INFN Cagliari

  12. The positive preamplifier:b) measurements Response to a delta Threshold vs.Cd Noise vs. Cd ENC = 867e- + 36e-/pF Channel uniformity of noise and threshold: 7% r.m.s. Cross talk around 1% Power consumption of about 18mW per channel dominated by LVDS driver Analog measurement Digital measurement Simulation (CADENCE) calculation from noise theory W.Bonivento CERN/INFN Cagliari

  13. The positive preamplifier:b) measurements Problems of the discriminator: 1) it does not work below 10fC (need 5fC). It was tested on a chamber prototype efficiency plateau shifted by 100V w.r.t. to our best measurement (with ASDQ chip). 2) it slows down the signal rise-time significantly (input C of discr.) Peaking time vs.Cd 7ns are expected from p.a. alone Discriminator changed in next versions of the chip W.Bonivento CERN/INFN Cagliari

  14. The negative preamplifier:a) design N2,N3,N4 replaced by PMOS W.Bonivento CERN/INFN Cagliari

  15. The negative and positive preamp:frequency response negative CADENCE simulation positive Closed loop gain • 3dB level is at: • 16 MHz for negative • 23 MHz for positive Cdet=60pF Input impedance: below 50 W.Bonivento CERN/INFN Cagliari

  16. The negative preamplifier:b) measurements Response to a delta Cd=15pF Cd=100pF Linearity Measurements Simulation W.Bonivento CERN/INFN Cagliari

  17. The negative preamplifier:b) measurements Response to a delta Peaking time vs. Cd improved w.r.t first prototype Sensitivity vs. Cd Noise vs. Cd ENC= 951e- + 31e-/pF Channel uniformity of noise and threshold: 7% r.m.s. Measurements Simulation W.Bonivento CERN/INFN Cagliari

  18. The negative preamplifier:b) measurements Response to a quasi 1/t pulse Cd=15pF Cd=100pF quasi 1/t injector W.Bonivento CERN/INFN Cagliari

  19. The shaper:a) design Folded cascode fully differential balanced (CMF) Designed for 1ns peaking time (not to add to the preamp) Dominant pole (neglecting p.z. comp) at 160MHz W.Bonivento CERN/INFN Cagliari

  20. The shaper:a) design • 2-pole/zero network to compensate for the 1/t tail • basic idea from R.A.Boie et al.,NIM 192(1982)365 • adapted to a differential amplifier design (M.Newcomer, Penn) Cdet=60pF W.Bonivento CERN/INFN Cagliari

  21. The shaper:b) measurements This prototype chip with the positive preamplifier Response to a delta: single ended ouptut (true output will be differential) Cd=15pF Cd=100pF W.Bonivento CERN/INFN Cagliari

  22. The shaper:b) measurements Response to a delta: single ended output (true output will be differential). Saturation current on ( ) and off ( ) Measurements Simulation Linearity: improved with saturation current ON (changes the DC level at the drain of N0) W.Bonivento CERN/INFN Cagliari

  23. The shaper:b) measurements Response to a delta: single ended output (true output will be differential). Saturation current on. Cd=100pF Cd=15pF W.Bonivento CERN/INFN Cagliari

  24. The shaper:b) measurements Response to a delta: single ended output Sensitivity vs. Cd Peaking time vs. Cd. Faster than negative consistent with different bandwidth ENC= 1290e- + 40e-/pF with saturation current ON Noise vs. Cd Parallel noise term higher than preamp alone due to two preamplifiers at shaper input Measurements Simulation W.Bonivento CERN/INFN Cagliari

  25. The shaper:b) measurements Response to a quasi 1/t pulse Cd=100pF Cd=15pF W.Bonivento CERN/INFN Cagliari

  26. The shaper:b) measurements Response to a quasi 1/t pulse Peaking time vs. Cd Measurements Simulation Sensitivity vs. Cd Pulse width vs. Cd W.Bonivento CERN/INFN Cagliari

  27. Conclusions and perspectives Negative preamplifier and positive preamplifier with shaper chips tested and satisfying the requirements for LHCb operation • Amplifier+shaper+Voltage discriminator chip (following ATLAS MDT chip design) under test • +Baseline restoration chip under design W.Bonivento CERN/INFN Cagliari

  28. THE END