An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Notes From SwissFEL A. AKSOY, A. LATINA

  2. Layout • There are many things which can not be compressed • Bunch compressors • Beam transport • Photon lines • S-band section • Do we gain enough with high gradient?

  3. Stability • Amplitude and phase stability of X-band RF modules is critical; • SwissFEL X-band linearizer requires • phase jitter <0.07 deg • amplitude jitter < 0.1%. • The jitter is dominated by the driver amplifier and the HV stability of the modulator. • the modulators pulse to pulse HV needs to be stabilized to better than 1e-10. • We should make calculation as soon as possible not only for RF but also alignment..

  4. Breakdown • SwissFEL operating @100Hz has breakdown-rate of 4x10^-8 • which means ~1 BD/h over the entire facility. • CLIC operating @500Hz has breakdown-rate of 10^-7 which means 50 BD/h. • Breakdown-rate tolerances are still very tight • In case of a breakdown, thermal variation can be such that the system gets detuned, and we will loose a lot of time for recovering • We should study for fast tuning (additional module or controlling the detuning..)

  5. RF issues • X-band will have high power density at pulse compressor (500MW for X-band) • can cause high breakdown-rate. • Even at C band the breakdown occurring in cavity is less than breakdown occurring in waveguide • We should be careful with the length of compressed RF pulse. • The filling time of the cavity is already about 100ns. • For a pulse length of 150 ns might be challenging to accelerate several bunches. • We should take into account stucture length

  6. Issues about 500 Hz repetition • Pulse to pulse RF phase and amplitude stability problems with the modulators The linear voltage level needs time for being corrected. • 100 Hz already gives problems but probably manageable.. • Cooling down, lot of heat dissipation which make the cavity engineering challenging. • Needs 4 times more cooling than 100 Hz. More operation cost (SwissFEL would be 25 MCHF/year) • Operation S-Band @500Hz would be challenging • Beam loss @500Hz due to dark current would increase cost of infrasturcure • SwissFEL building 160 MCHF for 100 Hz repetition • Photon detectors @400 Hz can work.

  7. Undulators • In general high “k” values are better: • they allow you change the undulator gaps to tune the wave length. • Photon flux is proportional to K. • Large K values require big undulator period length and higher beam energies • If one wants to tune undulator strength “K” • Planar standart is prefereble • Constant wake field from beam bipe • Easy operation and machining • .However there exist limitation on period length. • The wake due to small aperture varies wiht K for in-vacuum undulators • One needs to make fine tunning for each K • in this sense going to higher energy and small laser wavelength, standart undulators has advantage

  8. User Requirements; Hard X-ray • Running at 15 GeV would give 5 times more photons and relax the micro-bunch instability by a factor 2 • Undulators would be similar, max 60 meters long each but longer period • means easiest fabrication • Relax a bit the emittance requirements • Photon lines would be longer to avoid damages on the screen • ~150 m instead of ~100 m lines • Single molecule/crystal imaging will need about 20 GeV machine in order to get 10^34 photon /pulse. • But at higher energy the incoherent synchrotron radiation starts deteriorating the electron beam along the undulator line. • Very high photon density per pulse would make the machine unique. • This allows decreasing the size of the samples (easy crystallization) increasing the chance of getting defect free samples • Example Interesting physics at 14 KeV photon energy • “Mössbauer effect”. Very sharp edge of Fe.

  9. Soft x-ray • Energy would be around 2 GeV • User requires high average laser power • Users work with the idea that they don’t need to re-use the samples) • Superconductive RF is the solution / MHz rep rate (take LCLS-II) • However full CLIC time structure, 150 bunch /pulse and 500Hz rap-rate would be useful for soft X-rays

  10. Recommendation from SwissFEL: • Choose one good application for proposing FEL. High photon power at one photon pulse. E.g. Single-Crystal Imaging, which is not covered by any FEL.