1 / 27

Products to X-ray People for Security

Products to X-ray People for Security. Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002. ANSI N43.17 Radiation Safety for Personnel Security Screening Systems Using X-rays. Secure 1000. Manufactured by Rapiscan Products Inc. Bodysearch.

mallory
Télécharger la présentation

Products to X-ray People for Security

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Products to X-ray People for Security Presented to the: Technical Electronic Product Radiation Safety Standards Committee May 22, 2002

  2. ANSI N43.17 Radiation Safety for Personnel Security Screening Systems Using X-rays

  3. Secure 1000 Manufactured by Rapiscan Products Inc.

  4. Bodysearch Manufactured by American Science and Engineering, Inc.

  5. Chronology • Sep. 1998: TEPRSSC Recommends a • Mandatory Standard • Apr. 1999: FDA Proposes New Project to • ANSI/HPS N43 • Nov. 1999: N43.17 TG Convenes • June 2001: Draft Standard Submitted to • N43 Committee • Apr. 2002: Final ANSI Approval

  6. Summary of Main Requirements • Subject dose limits: • 0.1Sv (10 µrem) Effective Dose per Scan • 250 Sv (25 mrem) per Year • Benefit vs. Risk & Negligible Individual • Dose (< 10 µSv/y) • Subject Informed of the X-Ray Exposure • and Associated Risk

  7. Summary of Main Requirements • Radiation Leakage: • 2.5 Sv/h (0.25 mrem/h) @ 30 cm from Surface • Bystander Protection: • Inspection Zone — 20 Sv/h (2 mrem/h) • Safety Interlocks • Labeling & Indicators

  8. Summary of Main Requirements • Operator Training • Manufacturer Records • User Facility Records

  9. Informative Annexes • Risks and Rationale • Measurement Protocol and Estimation • of Effective Dose

  10. Transmission X-Ray Products

  11. Transmission X-Ray(Conpass Body Scanner) Manufactured by MMC International

  12. Transmission X-Ray

  13. Specifications(Conpass Body Scanner) • Scanning Time: 10 Seconds • Anode Voltage: 70 - 200 KvP with 10 kV Step • Tube Current: 1- 3 mA with 0.5 mA Step • Dose to a Subject: 0.5 mrem per Inspection • Dose to Operator < 0.5 mrem per hour • Note: Other Systems Exist

  14. Mfr’s Proposed Uses • Passenger Control • Diamond Mines • Prisons • Public Offices • Banks • Etc.

  15. Issue • Non-medical Exposure to Ionizing Radiation • Linear no threshold model • Societal benefit from increased security

  16. Principles • 1 mrem Negligible Individual Dose • 100 mrem Annual Public Effective Dose Limit • Individual or Society Receives a Clear and Compelling Benefit that Outweighs Risk • Dose as Low as Reasonably Achievable

  17. Negligible Individual Dose • NCRP Recommends: An Annual Effective Dose Of 1000 µRem Be Considered A Negligible Individual Dose Per Source Or Practice • Magnitude of the dose • Difficulty in detection and measurement of dose and health effects • Estimated risk for the mean and variance of natural background radiation exposure levels

  18. Transmission vs. Backscatter • X-Ray Transmitted Through the Subject • Image Interpretation Significantly More Complex • Adjustable Technique Factors (More Complex) • 100x More Dose to Subject

  19. Regulatory Status • They are Not Medical Devices • They are Electronic Products that Emit Radiation • Currently No Federal Performance Standard Applies to these Products (21 CFR 1010 through 1050)

  20. FDA’s Proposed Response • Guidance Document • Radiation Safety Recommendation • Mandatory Performance Standard • New Instruments • Suggested State Regulations

  21. Proposed Mandatory Standard • Based on ANSI N43.17 • Dose Limit • Interlocks • Labeling & Indicators • Controls • Product Performance Only • Use Covered in a Radiation Safety Recommendation

  22. Discussion • Societal Benefit vs. Risk • Appropriate Use? • Scope of Standard • What Products? • Alternatives Based on Intended Use? • Controls – Fixed or Automatic?