1 / 36

STORAGE

STORAGE. DATA PROTECTION. BUSINESS CONTINUITY. VIRTUALISATION. Next-generation EMC VNX (“VNX2”) Technical Overview Unleash the power of flash. Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk. VNX Hardware. Core Architecture. Management and Integration.

mei
Télécharger la présentation

STORAGE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STORAGE DATA PROTECTION BUSINESS CONTINUITY VIRTUALISATION Next-generation EMC VNX (“VNX2”) Technical Overview Unleash the power of flash Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  2. VNX Hardware Core Architecture Management and Integration Data Protection and Disaster Recovery Complimentary Solutions Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  3. FLASH Transformed Storage Storage System Design is Book-ended by Opposite Technologies Drive ROI LOWEST$/IO 400GB SSD SSD 40X better thanSSD 16Xbetter than NL-HDD SSD 15K HDD LOWEST$/GB 4000 GBNL-HDD 600 GB 15K HDD NL-HDD NL HDD Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  4. FLASH Drive Reliability and Data Integrity EMC Flash = Enterprise Grade Flash • SLC (Single-Level Cell)for FAST Cache • 30 writes per day per cell non-stop for 5 years • 4,300 writes per second for a 100GB drive • eMLC (Enterprise Multi-Level Cell) for FAST VP • 10 writes per day per cell non-stop for 5 years • 1,500 writes per second for a 100GB drive • Cell over provisioning, for recovery of worn cells • Cell level sparing • Load wearing, balances cell updates • Writes are spread across all available cells • MTBF >2Million hours (HDD~1.5M Hr) • SSD DRAM implements write amplification NEW Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk HARDWARE

  5. The New FLASH-Optimized Hybrid Array The performance of FLASH with the efficiency of tiering Takes full advantage of the low latency of FLASH FLASH-optimized software and data services Delivers progressively lower $/IOPS at scale Moves inactive data to NL-HDDs for lowest $/GB Controller NEW SSDs HDDs Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  6. 2-5 x IOPS The new VNX Models 2 x IOPS of VNX5300 2 x IOPS of VNX5500 2.5 x IOPS of VNX5700 3 x IOPS of VNX7500 5 x IOPS of VNX7500 ** Initial support is for 1000 drives Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  7. NEW Flexible Storage Tiers Optimize TCO with tiered service levels • SAS (HDD) options • 3.5” drives (195 drives/ rack with 3U DAE, 555 drives / rack with 4U DAE) • 600GB, 900GB 10K • 300 GB, 600 GB 15K • ~ 140 (10K) to ~ 180 (15K) IOs per second • 2.5” Drives (500 drives/ rack) • 600GB and 900GB 10K RPM • 300GB 15K • ~ 140 IO/s (10K), ~ 180 IOs per second (15K) • Near-line SAS (HDD) options • 3.5” drives (195 drives/ rack) • 1TB, 2TB and 3 TB 7.2K RPM • ˜ 90 IOs per second • 2.5” drives (500 drives/ rack) • 1TB 7.2K RPM; ˜ 90 IOs per second SAS back-end connect for performance and reliability • Up to 24Gb (4x6 Gb) per SAS bus • Point-to-point, robust interconnect Flash (SSD) options • Highest performing drives • Fast Cache SSDs (SLC) • 2.5” and 3.5” • 100 GB, 200 GB • ~5,000 IOs per second • FAST VP SSDs (eMLC) • 2.5”; 100 GB, 200 GB, 400GB • ~3,500 IOs per second AUTOMATIC DATA OPTIMIZATION Flash SAS (10K /15K rpm) Near-line SAS (7.2K rpm) Host LUNs VIRTUALSTORAGE POOL New drives for next gen SAN LUNs NFS/CIFS NAS Volumes Highest performance Good performance Highest capacity Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk HARDWARE

  8. VNX Hardware Core Architecture Management and Integration Data Protection and Disaster Recovery Complimentary Solutions Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  9. NEW Introducing MCx Multi-Core technology to unleash greater system performance Dynamic Multicore Optimization Static Core Utilization RAID I/O DRAM Cache FAST Cache Data Services Management Available Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  10. NEW Multi-Core Cache Performance, Efficiency and Ease-of-Use Benefits • Performance improvements based on: • Modularization of cache engine • Delivers seamless performance, scales with cores • Supports large write cache sizes(close to maximum DRAM size) • One large, shared cache, no R/W partitioning • Improved read hits, fewer forced flush scenarios, no user manageable settings • Adaptive cache management and improved cache algorithms • Adjusts to changing IO profiles • Data can remain in Write cache after an idle flush • Improved pre-fetch Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  11. NEW Multi-Core RAID Performance Scales with Advanced Availability and Flexibility • Permanent Sparing • Any unused drive is a potential hot spare • Hot Spares become a permanent part of the RAID Group, no equalization required* • 3 Policies: • Recommended • No Hot Spares • Custom • Portable Drives • No slot to drive location dependency • Drives can be relocated between busses, shelves etc • 5-Minute timeout before hot spare invoked • Used for bus balancing; can remove whole RAID groups for longer periods (will Fault) • Have to go back in same VNX Bus 2, Enclosure 0 RAID group 1 Bus 0, Enclosure 0 Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk * CLI available to copy spare back to replaced drive RAID group 2 VAULT

  12. FAST Suite for File and Block Lower Capex with eMLC and better FAST VP granularity FAST Cache, FAST VP, and File and Block • FAST Cache • Caches from HDD or NL-HDD tiers to FAST Cache-Optimized SSDs at page granularity of 64K • FAST VP • Dynamically moves data between FAST VP-Optimized SSDs, HDD, and NL-HDD tiers at slice granularity of 256 MB • Deploying both together ensures maximum IO granularity • LUNs may be deployed for SAN or used for NFS or CIFS LUNs SAN LUNs NFS/CIFS NAS Volumes NEW 64K 64K 64K 256M 4,096 times more granular FASTCache Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk HDD NL-HDD SSD FAST Virtual Pool

  13. NEW Multi-Core FAST Cache Improved Performance and Efficiency of FAST Cache • Performance enhancements • New Stack Order (MCC above MCF) • Reduced cache hit pass-through overhead • Increased promotion queue • Proactive clean optimization • Improved responsiveness as promotions are not delayed by flush of dirty pages • Faster initial warm-up • Single hit incurs promotion until FAST Cache is 80% full. Multi-Core RAID Backend Driver Upper Redirector FAST Cache Multi Core Cache Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  14. New to VNX VNX Series RAID Configurations Improve storage pool efficiency Q3 2012 17%Overall Pool Savings 38%Lower Flash Starting Cost SSD SAS NL-SAS SMALL SETS FOR SSD LARGE SETS FOR NL HDD RAID5 RAID5 RAID6 4 + 1 8 + 1 14 + 2 Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  15. FAST VP Policies Policy ensures storage service levels are met Highest Available TierMaximize performance e.g., high-performance OLTP system 1 Auto-TierOptimize TCO and performance e.g., databases with varied levels of activity among tables, or file systems with varied levels of activity across files 2 LUN 1 LUN Lowest Available Tier Reduce TCO e.g., archived or infrequently accessed data 3 2 LUN 3 LUN 4 New to VNX Start High, then Auto-Tier Maximizes initial performance;then optimizes for TCO 4 STORAGE POOL SSD HDD Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk FAST SUITE LUN 4

  16. New to VNX Automated Pool Rebalancing Advanced pool optimization functionality • Storage Pool Rebalancing after pool expansion • Improves pool performance by balancing data across all drives in pool • Re-distributes data across private RAID groups to avoid hot spots • Prior to this announcement, to address pool performance, users had to expand with the same number of drives of the original pool size • Load balancing within a tier • Relocate within tier, based on activity level • Occurs as part of FAST VP relocation • During user-defined tiering relocation window • “No Data Movement” tiering policy WILL allow load balance within a tier Auto Rebalancing After Expansion Relocate within a Tier Virtual Pool Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk EFFICIENCY

  17. NEW VNX Block Deduplication Reduce CAPEX by 50% or More • Deduplication of data at 8KB granularity • Deduped LUNs are Thin LUNs • Settable per pool LUN • Thick, Thin and Deduped LUNs supported in a single pool • Freed up blocks/slices are available for re-use within storage pool • Deduplication occurs out of band to minimize I/O impact User Changes Read De-dupe Engine De-dupe Index Database LUN LUN • Improves VDI efficiency • Reduce $/VM deployment costs Free Pool Storage Pool Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  18. NEW EMC VNX Active-Active for Block Lower risk with increased availability within data centers • Eliminate application time-outs • No trespass • Load balancing delivers up to 2X performance • All paths are active • Available for block on Classic LUNs • Ideal for apps that need highest level of availability and do not require advanced data services like FAST LUN Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  19. NEW Virtual Data Mover (VDM) Enhancements Lower risk with online file migrations during Tech Refresh • VDM File Systems are replicated with VNX Replicator • RPO set to minimum ~ 30 secs • Automated migration process initiated • Fsids, log, config, context etc maintained • Migrates paused SnapSure snaps • Transparent to clients in most cases • Windows, Hyper-V, VMware, etc • Failover time from 30 seconds • Intended to address planned down time scenarios • Not a DR or mobility solution initially Data Mover Data Mover VNX B VNX A Migrate VDM 1 (f/o) VDM 1 Config Data Config Data FS Replicator VDM 2 VDM 3 Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk Config Data Config Data

  20. VNX Hardware Core Architecture Management and Integration Data Protection and Disaster Recovery Complimentary Solutions Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  21. Improve Management Productivity New Unisphere Management Suite UNISPHERE Intuitive, task-based systems management UNISPHERE REMOTE Manage XtremSW Cache and thousands of VNX/VNXe VNX MONITORING & REPORTING Powerful insights and planning ahead Management Suite Also includes Unisphere Quality of Service Manager and Analyzer Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  22. Optimized for VMware vSphere Seamless virtualization experience and acceleration VAAI* offload Unisphere Storage Administrator vCenter ServerIntegration and VASA** Virtual Server Administrator • Less net I/O • More VMs • Faster response • 10X Manage storage and VM resources in unison Control offload functions and integrated replication Manage storage and VM resources in unison Control offload functions and integrated replication * VAAI = VMware vStorage APIs for Array Integration ** VASA = VMware vStorage APIs for Storage Awareness Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  23. Optimized for Microsoft Hyper-V Seamless virtualization experience and acceleration API/ODX* Storage administrator Unisphere System administrator ESI/SCOM Integration 7x Copy Acceleration 30x Lower CPU Utilization Automatic Space Reclamation Manage storage and VM resources in unison Control offload functions and integrated replication VM/Storage Management End-to-End Monitoring Orchestration Automation New to VNX Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  24. New to VNX Full Hyper-V ODX Support Virtual Windows 8 and Server 2012 deployments • Array Offloaded Data Transfer (ODX) • Offload functions to storage system to free up host cycles • Improvements to SMB protocol(3.0) • Multi-Channel, Branch Cache v2,in-flight encryption increase performance and protection • Hyper-V over NAS for added flexibility 1st in Market Copy data twice as fast withno network overhead Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  25. VNX Hardware Core Architecture Management and Integration Data Protection and Disaster Recovery Complimentary Solutions Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  26. New to VNX VNX Snapshots for Block Enterprise Scalability and Functionality with New Use Cases Source LUN • Scalability • 256 writable snaps per LUN • Thinly provision many copies • High performance on writes • Snap space consumed from virtual pool • Advanced functionality • Branching (Snap of a Snap) • Clone support • Consistency Groups • Supports delete out of order • Instant Restore • Packaging • Included in Local Protection Suite and Total Protection Pack … Mon Tue Wed … SAP team 1 SAP team 2 Dev/Test Copy Reporting/Analysis Other.. Backup Proof Points • Up to 90% space savings • Use up to 256 copies Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  27. Continuous Protection with VNX & RecoverPoint Data protection, replication, and disaster recovery solution • Increased performance as replication processing is handled off the array • DVR-like recovery to any point in time • Up to 90% WAN bandwidth reduction • Dynamic switching between synchronous and asynchronous replication • Point-in-time recovery with VMware vCenter Site Recovery Manager • More affordable with free virtual RPA and synchronous replication over IP RecoverPoint Family CDP: Local Protection New for VNX1 & 2 CRR: Remote Protection T0 T+90 CLR: Concurrent Local and Remote Protection Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  28. Continuous Operations with VNX & VPLEX Eliminate downtime within and across data centers Improved availability Nondisruptive migrations and zero downtime for planned and unplanned outages Increased asset utilization Active-active data access, load balance and extend local VMware and clustering functionality over distance APP APP APP APP APP APP APP APP APP APP APP APP OS OS OS OS OS OS OS OS OS OS OS OS VPLEX VPLEX Flexible business operations Granular storage acquisition (pay-as-you-grow), isolate workloads and spread your investment Encapsulated LUN Encapsulated LUN VPLEX allows for the SAMEinformation to be READ/WRITE accessible at the SAMEtime in two SEPARATElocations Instance A ActiveDomain Instance B Active Domain Nearly 50% of VPLEX deployments have a VNX Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  29. Application Protection with AppSync 1.5 Lower cost with self-service protection SIMPLE SLA-DRIVEN SELF-SERVICE New for VNX1 & 2 GOLD SILVER BRONZE • Dynamic Application Protection—Optimized for Virtual Apps Receive alerts when SLAs are not met Protect and restore critical applications in minutes Enable application owners to drive protection EMC AppSync supports VMware, Exchange 2010 and 2013, SQL 2008 and 2012, Block storage, NFS file Shares, RecoverPoint, VNX Snapshots, and NAS snapshots and replication Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  30. VNX Hardware Core Architecture Management and Integration Data Protection and Disaster Recovery Complimentary Solutions Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  31. EMC XtremSF and XtremSW Cache • PCIe flash card deployed in the server to dramatically improve application performance by reducing latency and accelerating throughput • Use cases: • Local storage device for read and write acceleration • Caching device for read acceleration with data protection using XtremSW Cache 550GBeMLC 700GBeMLC 1.4TBeMLC 2.2TBeMLC 350GBSLC 700GBSLC Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  32. EMC Cloud Tiering Appliance • Simple, scalable, policy-based file tiering, archiving, and migration • Reduce CapEx and improve utilization of primary storage • Lower OpEx for infrastructure • Reduce backup windows and improve performance AUTO-TIERING FAST VP EMC VNX Public cloud ARCHIVING Only auto-tiering solution for in-the-box, between boxes, and to the cloud EMC VNXe EMC Data Domain NAS MIGRATION Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk EMC VNXe NAS EMC VNX

  33. EMC Syncplicity for VNX iPHONE iPHONE ANDROID File Synchronisation and Sharing with a Consumer-grade user experience and Enterprise-grade file protection OUTSIDE FIREWALL iPAD iPAD Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk MACBOOK AIR

  34. EMC VNX Next-Generation - What’s New? • Sandy Bridge CPUs and PCIe Gen 3 – 40GbE and 16Gb FC ready • Multi-Core Optimisation (MCx) for RAID, Cache and FAST Cache • ŸIncreased cores, memory, drive count and FAST Cache capacity • Scaling to one million 8k read IOPS • ŸSupport for 100GB, 200GB and 400GB lower-cost eMLC Flash drives • De-duplication of block LUNs included as standard • Adaptive Cache management with a shared pool for reads and writes • Improved FAST Cache performance and warm-up times • Active/Active LUN access for improved performance and availability • ŸMore granular FAST VP segment sizes – down from 1GB to 256MB • Permanent drive sparing and drive portability • ŸVNX Monitoring and Reporting included as standard • Automated online file system migrations from Celerra and VNX systems • Drives and DAEs (not data) can be re-used from existing VNX systems Tel: 01932 593943 Email: info@snsltd.co.uk Web: www.snsltd.co.uk

  35. Further Information Keep up to date with our blog at http://blog.snsltd.co.uk Visit our YouTube channel at http://www.youtube.com/user/SNSLimitedUK To learn more register for one of our free seminars at http://www.snsltd.co.uk/seminars If you have any questions on the content please email info@snsltd.co.uk

  36. Thank-you