1 / 4

Outline of talk for Snowmass

Outline of talk for Snowmass. Introduction: studies performed to optimise detector design parameters this talk: effect of varying beam pipe radius: 3 values: 8, 15, 25 mm comparison of long-barrel (LDC) with short-barrel + endcaps (SiD) vtx det Vertex charge as tool for physics :

mervin
Télécharger la présentation

Outline of talk for Snowmass

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Outline of talk for Snowmass Introduction: studies performed to optimise detector design parameters this talk: effect of varying beam pipe radius: 3 values: 8, 15, 25 mm comparison of long-barrel (LDC) with short-barrel + endcaps (SiD) vtx det Vertex charge as tool for physics: examples: left-right forward-backward asymmetry ( S. Riemann) background reduction in multijet events Reconstruction method for vertex charge: event sample, definition of L/D, Qvtx, MPt, eb, l0 show lpm, l0 as fct of eb – point out that l0 is used to quantify performance, since it determines how well background can be suppressed, if background is high, for the gold-plated cases, in which b-quarks hadronise to B+-

  2. Effect of varying CM energy: at low sqrt(s) average track momentum lower (mult scattering!) & seed vertex closer to IP (plots of Ldec vs sqrt(s), l0 vs Ldec & percentages of vertices in beam pipe and between vtx det. layers at different energies (50 .. 500 GeV))  Qvtx reconstruction more challenging at lower energies Polar angular dependence: plot l0 vs cos q at 4 energies (see last Phys. Mtg), for standard detector: poorer performance at low sqrt(s) & large cos q , as expected Varying the beam pipe radius: introduction with schematics of the 3 detectors compared, point out that beam pipe needs to be thicker if its radius is larger, for mech. integrity; plot of l0 vs (L/D)min, & cut values chosen for the 3 detectors (0.17, 0.18, 0.19) plot l0 vs cos q comparing the performance of the 3 det’s at sqrt(s) = 100 GeV: l0 increases from ~ 9.5% to ~ 12.5% when going from standard to large Rbp vtx detector, in a typical cos q bin (0.2 < cos q < 0.25)

  3. Plots summarising Rbp comparison: l0 vs sqrt(s) in 2 bins of cos q : (0.2, 0.25), (0.85, 0.9), in central part of det, difference standard – large Rbp det more pronounced, at the edge, difference between standard and small Rbp det is larger l0 vs sqrt(s) averaged over 0 < cos q < 0.9 (relevant for multijet processes): at lower energies, difference between detectors is larger Translating l0 values into effective luminosity: introduce n-jet luminosity factor, quantifying how much more integrated luminosity the detectors with changed Rbp would need compared to the standard detector (small radius det yielding factor below 1); obtained from increasing Ldec cut until l0 of ‘less good’ detector agrees with that of ‘better’ detector; { in practise, one would use events with lower Ldec with reduced weight – would expect weight to be close to 0 if background >> signal } plots of 2- and 4-jet luminosity factors, at sqrt(s) = 100 GeV (& possibly 50, 500 GeV, if time permits – values for those energies currently in preparation): at 100 GeV, factors are 1.6 (Rbp = 25mm) and 0.7 (Rbp = 8 mm), respectively

  4. Comparison with SiD detector: SiD short-barrel + endcaps vertex detector, inserted into the same ‘global detector’ geometry used for LDC detector (TESLA geometry) plots ofl0 vs cos q at sqrt(s) = 100 GeV and energy dependence of cos q average (as for Rbp comparison): results still in preparation; plot to determine L/D cut showed overall performance very similar to standard det., comparison in terms of cos q dependence in preparation

More Related