1 / 13

Plymouth North High School Wind Turbine Project

Plymouth North High School Wind Turbine Project. Model High School Site 41 Obery Street Plymouth, MA. Project History. Atlantic Design Engineers, LLC (Atlantic) conducted an initial wind turbine siting and feasibility analysis of the PNHS property.

moana
Télécharger la présentation

Plymouth North High School Wind Turbine Project

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Plymouth North High School Wind Turbine Project Model High School Site 41 Obery Street Plymouth, MA

  2. Project History • Atlantic Design Engineers, LLC (Atlantic) conducted an initial wind turbine siting and feasibility analysis of the PNHS property. • Atlantic completed a series of studies to obtain a better understanding of the impacts associated with a turbine in this location including: • Shadow Flicker Impact Study • Photosimulations from various locations around the site • Zone of Visual Influence (ZVI) Map • Atlantic then completed a noise monitoring program and Acoustic Analysis to determine the background (ambient) noise levels at various locations surrounding the site; and selected a representative turbine (900kW EWT) to acquire a better understanding of the specific acoustic impacts the project may have on nearby residential neighborhoods.

  3. Conceptual Site Plan – 900 kW Turbine

  4. Conceptual Site Plan – 750 kW Turbine

  5. Conceptual Site Plan – 225 kW Turbine

  6. Energy Production Estimates Energy production numbers are based on the following: • Predicted Wind Resource: • 5.4 m/s at 40 m (131’) AGL • 5.7 m/s at 55 m (180’) AGL • 6.4 m/s at 75 m (246’) AGL • Annual energy production loss factor of 8% • 75 m EWT 54-900: 900 kW Rated Capacity: 2,124,000 kWh/year* • 71 m Gamesa G58: 850 kW Rated Capacity: 2,117,000 kWh/year • 55 m Aeronautica 54-750: 750 kW Rated Capacity: 1,604,000 kWh/year • 40 m Aeronautica 29-225: 225 kW Rated Capacity: 313,000 kWh/year *: Model used to complete Shadow Flicker, Visual, and Noise Impact Assessments

  7. Questions/Comments

More Related