1 / 31

Engineered Products Make-Up Air for Heating and Cooling

Engineered Products Make-Up Air for Heating and Cooling. MAKE-UP AIR. Why do we need make up air?. TYPICAL APPLICATIONS. EXHAUST AIR BUILDING PRESSURIZATION BUILDING VENTILATION. EXHAUST AIR. KITCHEN HOODS MANUFACTURING APPLICATIONS PAINT BOOTHS PROCESS AIR. BUILDING PRESSURIZATION.

moe
Télécharger la présentation

Engineered Products Make-Up Air for Heating and Cooling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Engineered Products Make-Up Air for Heating and Cooling

  2. MAKE-UP AIR Why do we need make up air?

  3. TYPICAL APPLICATIONS • EXHAUST AIR • BUILDING PRESSURIZATION • BUILDING VENTILATION

  4. EXHAUST AIR • KITCHEN HOODS • MANUFACTURING APPLICATIONS • PAINT BOOTHS • PROCESS AIR

  5. BUILDING PRESSURIZATION • CORRIDOR PRESSURIZATION • FIRE CONTROL • KEEPS ODORS IN APARTMENTS, ETC. • BUILDING PRESSURIZATION • REDUCES OUTSIDE AIR INFILTRATION

  6. BUILDING VENTILATION • BUILDING VENTILATION • CONSTANT VOLUME • INTERMITTENT VOLUME

  7. HOW CAN STERLING HELP?? • Sterling Offers a Complete Line of Outdoor and Indoor HVAC Equipment to Satisfy Your Make-Up Air Needs.

  8. Outdoor UnitsUnit Types • Model “GR” Option “G”– Gravity Vented Outdoor • Model “GR” Option “P”– Power Vented Outdoor

  9. Indoor UnitsUnit Types • Model “GG” – Power Vented Indoor

  10. Indoor UnitsUnit Types • Model “GX” – Separated Combustion Indoor

  11. Indoor/Outdoor UnitsUnit Types • Model “AH” Air Handler

  12. Arrangements • Consists of Individual Pre-Engineered Modules Arranged to Address Your Individual Applications

  13. Furnace Type • Trane GR Duct Furnaces are Available in Two Types. • Standard Temperature Rise (20°- 60°F) • High Temperature Rise (60°- 90°F) • GG/GX 30°- 80° Rise Only • Furnace Type Also Determines the Unit Access Side (Left or Right) Based on the Direction of Airflow Through the Unit.

  14. Furnace Construction Material • Duct Furnace Heat Exchangers are Available in 3 Types of Steel • Stainless Steel Packages: Provides a Total Package Protection by Including 409 SS Burners and Flue Collector • Aluminized Steel • 409 Stainless Steel • 321 Stainless Steel

  15. Gas Type • Natural Gas • Propane (LP) Gas • Natural Gas w/ 100% Lockout • Combine with a Model “GR” Power Vented Furnace for IRI Compliance

  16. GAS CONTROL • A Full Range of Gas Controls, Including: • Single Stage • Two Stage • Electronic Modulation • Room Sensing • Duct Sensing (W/, W/O Rm. O/R) • Others, Including 4-20 mA & 0-10 VDC Controls and Multi-Furnace Staging

  17. Coil Options • Factory Installed Coils • Direct Expansion (DX) • Chilled Water • Steam • Hot water • Draw Through Design Maximizes Coil Efficiencies • Full Size ASHRAE 62 Compliant Drain Pan • 4 Row & 6 Row, Single or Dual Circuit • Cooling Coil 1,000-6,300 CFM Range* • 3-30 Tons, But There is Flexibility. When in Doubt, Call!

  18. Indoor/Outdoor UnitsUnit Types • “EV” Evaporative Cooler Section

  19. Features and Benefits • Heating Capacities from 100 to 1,200 MBH • Air Flows from 800 to 14,000 CFM • 80% Efficient/Natural and Power Vented Duct Furnaces

  20. Features and Benefits • 18 Gauge Cabinets Painted Trane Grey • 20 Gauge Aluminized Steel Heat Exchangers • Single Stage Redundant Gas Valve • Low internal static pressures allow for smaller motor break horse power requirements

  21. Features and Benefits • Standard Left Hand Access, Right Hand Optional • Multiple Gas and Air Control Options • 1” Matte Face Insulation

  22. Features and Benefits • Economizer Control • Door Safety Interlock

  23. Features and Benefits • Ship Loose Parts List

  24. Features and Benefits 1 2 8 3 9 4 10 5 11 6 12 13 7

  25. Features and Benefits T - Status Lamps E - Airflow Proving Switch

  26. Motor Types • Open Drip Proof (ODP) • Premium Efficiency (PEODP) • Totally Enclosed (TE) • Premium Efficiency (PETE)

  27. Air Inlet Configuration • Indicates • Use of Outside and / or Return Air • Use of an Air Hood (Shipped Separately)

  28. Air Control & Damper Arrangements • Twenty Air Control Options Available • Options Range From Simple Two-Position Dampers (Open & Closed) to Various Modulating Controls to ASHRAE Cycles I, II & III • Other Options Available Including Enthalpy Controlled Economizer, Pressure Sensing & CO2 Monitoring • Refer the Catalog For Full Descriptions of the Air Control and Damper Arrangements

  29. Economizer Accessories • Enthalpy Control Outside Rain Hood • Enthalpy Control Inside Rain Hood

  30. Low Leak Damper 409 SS Furnace Drip Pan High Altitude Derate Input Derate Evaporative Cooler 12” CELdek® Media 8” & 12“ GLASdek ® Media Clogged Filter Switch Manual Blower Switch Firestat (Supply and / or Return) Freezestat (Time Delayed) Ambient Lockout Interlock Relays (Specify Purpose) Moisture Eliminators Horizontal Return Status Lamps Double Wall Construction Service Convenience Package High / Low Gas Pressure Switch Filters (TA, WA & Pleated) Through the Base Utility Penetrations Factory Installed Options

  31. High Pressure Regulators Time Clocks GFI Convenience Outlet Thermostats DuctStats Disconnect Switches Evaporative Cooler Fill & Drain Kit Freezestat Remote Control Panel Field Installed Accessories