An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NGN Multi-Service Interconnect Link (NGN-MSIL)Robin Charles

  2. BT’s 21CN CP MULTI-SERVICE INTERCONNECT LINK NGN Multi-Service Interconnect Link • Enable CPs with similar IP based networks to interconnect with BT • Capable of supporting multi-services over the same link • Several Industry SoRs for NGN-MSIL have been received

  3. Border Gateway Border Gateway Border Gateway Border Gateway NGN Multi-Service Interconnect Link CSH CP BT TDM PPC NGN Multi-Service Interconnect Link PPC NTE NTE PSTN/ISDN PSTN/ISDN 21CN Fibre (‘Fat’ Pipe) Multi-Media Multi-Media With ISH Customer Provides ISH

  4. NGN-MSIL • Design based on SDH GFP , as Ethernet and MPLS standards are not mature (particularly for latency, security and OAM). • Will have independent service-specific conveyance riding on top of Point of Handover (PoH) • Dimensioning starting at STM-1 for SDH or Gig-E • Option with optical transport (CWDM) with SDH and Ethernet interfaces

  5. Scope • Interfaces: • TDM - STM1, STM4 and above • Ethernet – VLAN’s to support PSTN Voice • Resilience options (Service to define requirements)

  6. SDH • An operationally well-understood and trusted technology that can support a range of services • Provides strong trail separation via use of Virtual Containers but this does not give good granularity for bandwidth allocation per trail • Each service can be assigned to an SDH VC. Ethernet and packet services can be supported by General Framing Procedure (GFP) in SDH. Virtual concatenation (VCAT) would be used to support services and interfaces requiring bandwidths that are multiples of the SDH V • High cost solution

  7. NGN-MSIL • This is a replacement for the existing Handover. • Link is Service independent • VLANS will be configured for Services. • Two options for delivery - ISI, CSI • Standards:- SDH, Ethernet physical, Ethernet VLAN, Ethernet VLAN tag addressing. • Need to secure separate paths per customer • Link SLA’s for fulfilment and assurance to align to the SLA’s for the individual services carried by NGN-MSIL

  8. Call Server Call Server NGN Interconnect Basic Diagram forPSTN/ISDN CP BT SIP (I) Signalling C M S A N N T E N T E N T E MSIL Border Gateway Border Gateway Metro Node Fibre Multi Service Access Node Copper Multi Service Access Node Multi Service Interconnect Link

  9. NGN Interconnect Call Conveyance • A basic diagram (previous slide) for NGN Interconnect and aspects of the additional complexity. • Standards – still a long way to go with many hurdles to jump • We envisage all the major PSTN/ISDN Call Types being replicated using a G711 Codec. • BT’s provision and repair to continue with improvements and modifications as necessary.

  10. Voice • Relationship between POH and Point Of Service Interconnect needs further discussion. • The physical POH at Tier 1 MSAN for migrating existing TDM voice or Metro node site to support all services POSI. • Connectivity required to reach from POH to POSI where POH is the MSAN site.

  11. Transport • Existing PPC SDH equipment does not have a GFP/SDH card. • The Link will be transparent to the service. • CSI the preferred delivery. • SDH is preferred delivery for Operations • Connectivity will be required to link POH and POSI. • Voice services will be delay sensitive, need to comply with NICC standards. • POH for NGN-MSIL will be Client interface on NTE. • Where optical interfaces are considered then optical drive distances will need investigating, e.g. use of 1310nm instead of 850nm to extend reach.

  12. Process • CP must have (or order new) NGN-MSIL prior to service • CP can then order the Services / Interfaces required • Rules need to be defined for Service ordering (plus additional Backhaul links) • CP must be responsible for Capacity Management. • Provision and management of client interface from CP NTE/NTU to BT Mux as required by the product. E.g. GE, STM1

  13. Pricing • For the Link , pricing expected to be connexion charges plus rental with a distance based element mapped to the PPC model. • (Existing services conveyed over the link will map to the current billing arrangements for the respective services.)

  14. Tactical delivery options • PPCs continue to be supported • Ethernet services could be delivered by WESB • -what bandwidth required? • -long term market for premium SDH/GFP bearer to carry Ethernet/IP? • WDM with dedicated wavelengths per service possible –but not for ISH