1 / 18

Statistical Data Analysis

Statistical Data Analysis. Prof. Terry A. Ring, Ph. D. Dept. Chemical & Fuels Engineering University of Utah. http://www.che.utah.edu/~geoff/writing/index.html. Making Measurements. Choice of Measurement Equipment Accuracy – systematic error associated with measurement.

naava
Télécharger la présentation

Statistical Data Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Statistical Data Analysis • Prof. Terry A. Ring, Ph. D. • Dept. Chemical & Fuels Engineering • University of Utah http://www.che.utah.edu/~geoff/writing/index.html

  2. Making Measurements • Choice of Measurement Equipment • Accuracy – systematic error associated with measurement. • Precision – random error associated with measurement.

  3. Definitions • Error – the difference between the measured quantity and the ”true value.” • The “true value” is not known!!! • So how do you calculate the error?? • Random errors - the disagreement between the measurements when the experiment is repeated • Is repeating the measurement on the same sample a new experiment? • Systematic errors - constant errors which are the same for all measurements. • Bogus Data – mistake reading the instrument

  4. Random Error Sources • Judgement errors, estimate errors, parallax • Fluctuating Conditions • Digitization • Disturbances such as mechanical vibrations or static electricty caused by solar activity • Systematic Error Sources • Calibration of instrument • Environmental conditions different from calibration • Technique – not at equilibrium or at steady state.

  5. Statistics • Mean xM • Deviation xi-xM • Standard Deviation  • Confidence level or uncertainty, • 95% confidence = 1.96  • 99% confidence = 2.58  • Please note that Gaussian distributions do not rigorously apply to particles- log-normal is better. • Mean and standard deviation have different definitions for non-Gaussian Distributions

  6. Comparison of means – Student’s t-test • v= n1+n2-2 • use the t-value to calculate the probability, P, that the two means are the same.

  7. Estimating Uncertainties or Estimating Errors in Calculated Quantities –with Partial Derivatives • G=f(y1,y2,y3,…) http://www.itl.nist.gov/div898/handbook/mpc/section5/mpc55.htm

  8. Way around the Partial Derivatives This approach applies no matter how large the uncertainties (Lyons, 1991). (i) Set all xi equal to their measured values and calculate f. Call this fo. (ii) Find the n values of f defined by fi = f(x1,x2,...,xi+si,...,xn) (11) (iii) Obtain sf from (12) If the uncertainties are small this should give the same result as (10). If the uncertainties are large, this numerical approach will provide a more realistic estimate of the uncertainty in f. The numerical approach may also be used to estimate the upper and lower values for the uncertainty in f because the fi in (11) can also be calculated with xi+ replaced by xi-.

  9. Equation Used f/f0 (9) 0.011968 (12) with + 0.011827 (12) with - 0.012113 Now try the same calculation using the spread sheet method. The dimensionless form of (12) is (after taking the square root) (17) The propagated fractional uncertainties using (15) and (17) are compared in Table 4. A further advantage of the numerical approach is that it can be used with simulations. In other words, the function f in (12) could be a complex mathematical model of a distillation column and f might be the mole fraction or flow rate of the light component in the distillate. Table 4. Uncertainties in Gas Velocity Calculated from (15) and (17) See web page with sample calculation done with Excel

  10. Fitting Data • Linear Equation – linear regression • Non-linear Equation • Linearize the equation- linear regression • Non-linear least squares

  11. Rejection of Data Points • Maximum Acceptable Deviations (Chauvenet’s Criterion)

  12. Example • xi-xM/=8.9-8.2/0.3=2.33 • xi-xM/=7.9-8.2/0.3=1.0

  13. Regression • Linear Regression • good for linear equations only • Linearize non-linear equation first • linearization leads to errors • Non-linear Regression • most accurate for non-linear equations • See Mathcad example

  14. Residence Time Measurements T T Time(min) Time(min) T=(To-Tin)exp(-t/tau)+Tin

  15. Non-Linear Fit Linearized Eq. Fit Flow Calc.s Temperature(C) Time (min)

  16. Results

More Related