An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design Point Studies for next step device National High-heat-flux Advanced Torus Experiment NHTX C Neumeyer 6/8/6

  2. Outline • Background • Method • Physics Assumptions and Plasma Shapes • Engineering Assumptions and Issues • - TF inner leg cooling • - Heat removal from machine • - Divertor heat removal • - Power supply utilization • Results • Conclusions

  3. Background: Options Studied • NSTX Center Stack Upgrade ~ 10s pulse • - adiabatic water cooled, sub-cooled, LN2 • - Paux= 10-20MW • - full, partial inductive • - OH coil, iron core • NSTX Center Stack Upgrade ~ 20-60s pulse • - active water cooled • - retain VV, PF coils, TF outer legs • NSTX Upgrade ~ 60s pulse • - replace center stack, PF, TF outer legs • - retain existing VV (kappa*a <=1.3m) • NSTX Replacement ~ 60s pulse • - all new machine Attractive mission: Ip ~ 4MA Bt ~ 1.5T Paux ~ 38MW

  4. Highlights of New Machine • High P/R • - plasma should accept Paux = 32MW NBI + 6MW RF = 38MW • Non-Inductive Sustainment • - solenoid sized for ramp-up flux only • Long Pulse • - active water cooling, 60 second pulse • Full Use of PPPL/TFTR Infrastructure • - full MG energy + grid power • - full PS capacity • - full NBI capacity • Some Incremental Infrastructure Required • - water flow • - 138kV substation

  5. Methodology • XL-based “systems code” using non-linear optimizer (‘Solver”) • Jardin/Kessel physics algorithms used for NSST were starting point • Continued evolution with Peng, Rutherford, Kessel for CTF studies • - See PPPL Report 4165 “Spherical Torus Design Point Studies” • Engineering & physics algorithms tailored to subject situation

  6. Physics Assumptions Solutions maximize Ip*Paux

  7. Range of Cross Sections = 3.674/SQRT(A_100) =0.6 Z=1.3m ~ limit of existing VV Simple limiter shape model: R0+a=1.473

  8. Limiter model vs. Divertor separatrix flux surface from J. Menard equilibria @ A=1.8

  9. Engineering Assumptions

  10. TF Inner Leg Cooling fPacking depends on J_avg and dZ Typical T v. t Adiabatic Cu H20 Possible x-section KCOOL model

  11. Machine Heat Removal TFTR ratings (may not be available anymore TBD)… Water tank = 33000 gallons (adequate) Cooling power = 20MW (adequate) Component cooling = 3300 GPM (~ 1/6 of requirement)

  12. Divertor Heat Removal 4” dia pipes are adequate for divertor supply/return manifolds (assume full power capacity on top and bottom)

  13. Power Supplies Use PS at 15kA per PSS (continuous rating of SCRs) Rep rate limited to ~ 1200s min due to 3.25kA rms rating Xfmrs OK (8 hrs) 5 parallel 750MCM per PSS ~ 50 parallel 1000MCM cables req’d for 200kA-60s/1200s

  14. Results (1)

  15. Results (2)

  16. Results (3)

  17. Results (4) NSTX New

  18. Conclusions • Sweet spot ~ A=1.8 should be pursued • Much work remains to • - develop and prove out physics and engineering aspects of design • - optimize water cooling aspects • Highlighted challenges • - TF bundle torsion and joint • - large water flows • - 200MW from grid • - restoration of MG capability