1 / 11

Revalidating Requirements: Rigging Hardware Case Study

Revalidating Requirements: Rigging Hardware Case Study. Anthony Underhill 321-730-6269 anthony.underhill@mantech.com capt_underhill@yahoo.com. “ We ’ ve always done it that way? ”. Is the requirement still relevant (effective) in today ’ s environment?.

neka
Télécharger la présentation

Revalidating Requirements: Rigging Hardware Case Study

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Revalidating Requirements:Rigging Hardware Case Study Anthony Underhill 321-730-6269 anthony.underhill@mantech.com capt_underhill@yahoo.com

  2. “We’ve always done it that way?” Is the requirement still relevant (effective) in today’s environment? WHY DOES THE SAFETY REQUIREMENT EXIST? How was the requirement validated? What were the circumstances at the time?

  3. FAST FORWARD TO TODAY Facility Cost ⇒ $110K annual User Mission Cost ⇒ $ 34K per mission TOTAL COST ON Eastern Range = ~$1M per year

  4. Cheap Insurance – Right? BUT IS IT MORE SAFE?

  5. Back to 1970 • US NAVY – high number of accidents • Causes: Uncertainty in the load High corrosion environment No Consensus standard for design • Solution: Annual 2 x rated load test • OSHA in its infancy • US Air Force Range • Adopt 2 x RL in ESMC (1984)

  6. Three Decades Later WHAT DOES ASME SAY ABOUT 2 x RL TESTING? Do not recommend exceeding 42% yield strength or fatigue may occur (ASME B30.20 interpretation)

  7. Is Range STD More Safe? • Does annual 2 x RL proof increase safety? • Are Magnetic Particle or Dye Penetrate inspections required to find critical flaws?

  8. MYTH #1 – 2 x RL increase Safety 10 Fatigue Rated shackles failed in fatigue when subject to 2 x RL BUSTED

  9. Myth 2 – Hair line crack Failed @ 1.28 x RL Failed @ 2.87 x RL BUSTED Failed @ 1.87 x RL Failed @ 2.28 x RL

  10. Additional Load Test Risk • Chance of improperly tested • Change of damage during installation • Change of damage during installation Fact: 10,500 crane lift during EPF construction. No rigging gear failed. ASME B30 used.

  11. CONCLUSION • REVISIT YOUR SAFETY REQUIREMENTS • REVALIDATE THEY ARE FULLFILLING THEIR INTENDED PURPOSE • YES – ENFORCE THEM • NO – CHANGE THEM