1 ton Xe? - a Boulby View

1 ton Xe? - a Boulby View. How the Boulby Collaboration see development of a 1 ton Xe experiment. Our Strategy. Progress on the ZEPLIN I detector. Prospects for PMT avoidance. Why 1 ton Xe? - Boulby View. Objective. To reach “bottom” of neutralino space

nikita
Télécharger la présentation

1 ton Xe? - a Boulby View

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1 ton Xe? - a Boulby View How the Boulby Collaboration see development of a 1 ton Xe experiment Our Strategy Progress on the ZEPLIN I detector Prospects for PMT avoidance

  2. Why 1 ton Xe? - Boulby View Objective • To reach “bottom” of neutralino space • Needs about 1 ton just to get sufficient recoil counts (a few hundred per yr) 1000 excluded 10 SUSY (mSugra) models have minimum sp ~10-10 pb (SI) probably excluded by accelerators events per kg per day 0.1 theoretically plausible 0.001 mass region 1 1000 100 10 WIMP mass (proton masses) case never so strong as now

  3. Why Xe? Motivation for Xe within the Boulby Programme • High-A target (Xe~130) for WIMP masses 50-500 GeV/c2 to reach 0.01/kg/d, and ultimately 0.0001 kg/d --> Complements NaI low-A, q(A) > 0.2 • Powerful discrimination (typically x100 better than NaI) with different techniques and geometry possible --> satisfies basic requirement for: (i) recoil identification (ii) diagnostic array capability • Big scale-up potential (yet retains recoil identification) --> experience of ICARUS, UCLA, Suzuki, Aprile, • Lower cost than alternatives? (low temperature, Ge..) • Prospects for isotopic enrichment better than Ge…...

  4. three discrimination techniques + Xe Ionisation +Xe Nuclear/Electron Recoil (1) scintillation pulse shape + Xe 2 Excitation - +e (2) ionisation-scintillation - low field- (recombination) * ** Xe Xe + Xe +Xe (3) ionisation-scintillation - high field, low threshold - * Xe 2 175nm 175nm Triplet Singlet single phase Xe two phase Xe 3ns 27ns gas 2Xe 2Xe liquid liquid World expertise • ICARUS-UCLA • Doke group (Japan) • DAMA • Columbia • UKDMC • ITEP XENON (PSD and Scint/Ion)

  5. basic ionisation-scintillation and high target mass - improve by x10 - UCLA concept demonstrate basic discrimination with PSD - set first limits ionisation-scintillation and high field - ultimate discrimination, low threshold - Boulby Collaboration Strategy A multinational programme ZEPLIN-MAX ion-scint two phase Xe 1000 kg ZEPLIN-II ion-scint two phase Xe 30 kg running ZEPLIN-I single phase PSD 4 kg ZEPLIN array under construction ZEPLIN-III Ion-scint two phase Xe high field 6 kg new (5 years) : Involved in programmes: UCLA, CERN/Padova, Torino, ITEP, Coimbra, Columbia, RAL, ICSTM, Sheffield

  6. Towards a 1 Ton design ZEPLIN array as a test bed • The Zeplin I, II, III array is a test bed for the scale-up --> solve basic underground operation problems --> understand mechanical, shielding and low background material issues --> understand discrimination issues: high field, low field --> what should it be called!? ZEPLIN-MAX, ZEPLIN IV….! Scale-up options • Several concepts are being explored (I) a single vessel of 1 ton (2) modular at level of about 80 kg: identical modules or different (3) larger modules of ~250 kg: identical modules or different (4) combination of high threshold and low threshold (5) removal of PMTs

  7. Some Tasks for 1 Ton • Engineering interfaces • -------------------- • Purification system • Xenon recovery system • High voltage systems • Scintillator handling system • Infrastructure Requirements • -------------------------- • Power and heat budget • Boulby facility requirements • - castle design, LN2 plant • Equipment spares • Health and Safety • Risk assessment and control • Sequencing • ---------- • Commissioning sequence • Required calibration test sequence • Transportation sequence • Installation sequence • Data Handling • ------------ • Data acquisition requirements and solutions • Data pipeline

  8. ZEPLIN I,I,III - 2001/2 complete and run the full ZEPLIN array • ZEPLIN I already running -->some upgrading of PMTs • ZEPLIN II under construction (with collaborators) -->installation, shielding, daq -->start running • ZEPLIN III under construction (with collaborators) -->installation, maintenance -->start running RESULT: (a) attain 0.01/kg/d, (b) diagnostic array with complementary techniques

  9. 3 modules 4 sub- units shielding 80 kg target ZEPLIN - 1 ton Concept ZEPLIN-MAX A BDMC multinational programme • Final design by mid 2003 • Modular, high and low threshold • Construction 2004+ RESULT: (a) attain 0.0001/kg/d, (b) diagnostic array with complementary techniques

  10. 10-3 10-4 10-5 ZEPLIN 2002/3 10-6 ZEPLIN I/II 2003 CDMS II CRESST II 10-7 ZEPLIN II/III 2004 10-8 ZEPLIN-MAX 2006 10-9 10-10 10 100 1000 ZEPLIN-XENON Predictions NaI 1996 limit WIMP-nucleon cross-section, pb ZEPLIN predictions based on prototype tests and operation of ZEPLIN I WIMP mass GeV

  11. 3 modules 4 sub- units shielding 80 kg target ZEPLIN-MAX One Concept ZEPLIN-MAX (1 ton) (a multinational programme) RESULT: (a) attain 0.0001/kg/d, (b) diagnostic array with complementary techniques

  12. ZEPLIN-MAX ZEPLIN-II ZEPLIN-III ZEPLIN locations at Boulby Stub 2 JIF Facility ZEPLIN-I

  13. Xe+ +Xe Xe2+ +e- (recombination) Xe* Xe** + Xe +Xe Xe2* 175nm 175nm Triplet Singlet 3ns 27ns 2Xe 2Xe UKDMC Xenon - ZEPLIN I

  14. ZEPLIN I Underground Boulby stub 2 laboratory xenon purification Top of ZEPLIN I veto Counts vs. time Xe temp vs. time Pb shielding room temp vs. time Stable operation demonstrated

  15. ZEPLIN Operations at Boulby

  16. ZEPLIN I Laboratory tests • PMT background events rejected by turret fiducial cuts as expected 137Cs events origin is where all 3 PMTs record identical signals turret events rejected by asymmetry cut • Compton veto (1 ton PXE) found to have ~50 keV threshold

  17. 0 500 1000 1500 2000 0 20 40 60 80 100 ZEPLIN I Laboratory tests pe/keV 2 • Light collection exceeds design spec of 1 pe/keV Z I data 1 theory 0 keV tau (ns) • Up to 50% difference in neutron and gamma time constants 50 keV 0

  18. ZEPLIN I Laboratory tests • Light Yield • Increases at low energy • Spatial Uniformity • 137Cs Source Data Theory

  19. ZEPLIN I Discrimination Gamma source  (ns) n Neutron source (ns) 10-20keV 20-30keV

  20. ZEPLIN I - Predicted Limits

  21. ZEPLIN I - Results Predictions for 1 year 85Kr < 10-17 atoms/atom

  22. CsI photocathodes in LXe: E.Aprile, NIMA 338 (1994), 328; NIMA 343 (1994), 121. GEM phototubes in noble gases:http://gdd.web.cern.ch/GDD/A.Buzulutskov, NIMA, 443 (2000), 164. Xe Gas GEMs CsI He Cooling Liquid Xe PTFE Reflector Field Shaping Rings CsI nucl.rec. elec.rec. PMT Removal for Scale-Up? • Sheffield test cell

  23. GEM Prototype Target High or low field operation In-house CsI photocathode production GEMs of Sheffield design from CERN

  24. GEM Rig

  25. ZEPLIN II (UKDMC collaboration with US and Italy) ionisation-scintillation discrimination OFHC copper plate ~30kg Lxe detector shielding, integration, readout, daq UCLA, Torino, Padova UKDMC cooling rings PTFE cone • Completion due end 2001

  26. ZEPLIN III (UKDMC collaboration with US and Russia) ionisation-scintillation - low threshold • 6 kg liquid Xe • High field (20 kV) operation for better discrimination Xe 31 two-inch photomultipliers 1kg test chamber result • Completion due end 2001

  27. 10-3 10-4 10-5 10-6 10-7 10-8 10-9 10-10 10 100 1000 UKDMC-BDMC Future NaI 1996 WIMP-nucleon cross-section, pb NAIAD/Xe 2002/3 Xe 2003/4 DRIFT 2004/5 Xe 2005 Xe-MAX 2006 WIMP mass GeV

  28. DAMA Xenon • Operating 6.5 kg Kr free (85Kr beta emitter) Liquid Xenon with PSD. • 99.5% enriched in 129Xe (spin-dependent couplings). • Viewed by three MgF2 PMTs through quartz windows (l=175 nm). • Measured quenching factor ~ 45% - 65%. • Stable operation at -105 oC. (see Nuovo Cim 19 (1996) 537)

  29. XENON - Kamioka (Scint/Ion) • Liquid-gas double phase xenon • 0.3l low background construction • 8 cm drift to proportional scintillation region • 99% background rejection for 10-100 keV • 3 months continuous operation • 1 kg experiment in Kamioka

  30. Possibilities • Ionisation - Germanium: GENIUS proposal for 1 or 10 tons Intrinsic low background but NO discrimination and expensive (mainly bb) • Scintillation - NaI: LIBRA (DAMA) 250 kg under construction Annual modulation (what if DAMA region ruled out), PSD not sensitive enough • Ionisation/thermal - CDMS?: Good discrimination but difficult technology and expensive • XENON - ZEPLIN-MAX proposal for 1 ton (UKDMC-BDMC, US, EU) Good discrimination, world expertise, simpler technology(?), less expensive • GAS - DRIFT-MAX proposal scale-up directional detector (UKDMC-BDMC, US) TOWARDS 1 TON? Motivation • To reach 10-10 pb

  31. - - - - - Current Direct Limits http://cdms.berkeley.edu/limitplots/ • Sensitivity ≈ 10-6 pb • DAMA: annual modulation of rate • CDMS: neutron background subtraction • UKDMC: ‘anomalous’ events preclude limit

  32. Summary WIMPs (10-9(or -12) pb < scp < 10-6 pb, 50 GeV < m <600 GeV) • DAMA NaI annual modulation as objective WIMP or fluctuating low energy noise? • UKDMC ‘anomalous events’ as surface alphas? Seen in Saclay (DAMA) crystal • CDMS recoil limit (almost) excludes DAMA Subtraction of neutron signal • Several detectors becoming sensitive at 10-6 pb • Many more direct searches underway to reach ≈10-8pb • Indirect n searches reaching sensitivities to exclude models