1 / 18

Longitudinal Emittance Measurement CERN Linac-2

Longitudinal Emittance Measurement CERN Linac-2. A talks based on archeological findings. (Pierre Tetu) Uli Raich. CERN AB - BI (Beam Instrumentation). Uli Raich. Thanks to R. Scrivens. Measurement Lines. Measurement line LTE/LTL. Protons. Alvarez Linac. RFQ. Lead Ions. IH structure.

norm
Télécharger la présentation

Longitudinal Emittance Measurement CERN Linac-2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Longitudinal Emittance Measurement CERN Linac-2 A talks based on archeological findings (Pierre Tetu) Uli Raich CERN AB - BI (Beam Instrumentation) Uli Raich Thanks to R. Scrivens CARE workshop on emittance measurements U. Raich CERN AB/BI

  2. Measurement Lines Measurement line LTE/LTL Protons Alvarez Linac RFQ Lead Ions IH structure Measurement line LBE/LBS Proton Linac 200 MHz RF frequence 100 µs pulse length 150 mA current

  3. Transverse emittance line Kicker Quadrupole Quadrupole Kicker SEMGrid X’ X’ X’ X’ X’ X X X X X at slit after 1. drift space after 1. quadrupole after 2. drift space after 2. quadrupole CARE workshop on emittance measurements U. Raich CERN AB/BI

  4. Transformation in Phase Space Kicker Quadrupole Quadrupole Kicker SEMGrid X’ X’ X’ X’ X’ X X X X X at slit first drift space first quadrupole second drift space Second quadrupol CARE workshop on emittance measurements U. Raich CERN AB/BI

  5. Transverse and longitudinal E E φ φ Transverse Phase Space Longitudinal Pase Space X’ X

  6. Buncher RF Longitudinal Phase Space Transformation Kicker • Spectrometer produces image of slit on second slit • second slit selects energy slice • first kicker sweep phase space over all energies • buncher rotates energy slice in phase space • at second spectrometer the phase distribution is transformed into an energy distribution analyzed by the second spectrometer • second kicker corrects for first kick Transformer SEMGrid Buncher Kicker Spectrometer magnet E E E E φ φ φ φ at slit first drift space buncher second drift space CARE workshop on emittance measurements U. Raich CERN AB/BI

  7. Transverse Emittance measurement Kicker Transformer SEMGrid Buncher Kicker Spectrometer magnet E E E E φ φ φ φ at slit first drift space buncher second drift space CARE workshop on emittance measurements U. Raich CERN AB/BI

  8. Photos of the line Kicker SEMGrid Buncher Kicker Spectrometer magnet CARE workshop on emittance measurements U. Raich CERN AB/BI

  9. U. Raich CAS Frascati 2008 Beam Diagnostics

  10. Calibration • Measurement of transformer signal with kicker “on” compared to intensity distribution on transformer when moving the slit with kicker off • Knowledge of the spectrometer magnet is needed to calculate eV/wire • Adjustment of the buncher phase must be done in such a way that the mean position in φ does not change with buncher on or off • Move the buncher phase by ± 30º and observe the mean displacement, knowing the spectrometer CARE workshop on emittance measurements U. Raich CERN AB/BI

  11. Original electronics 12 µs 2 MHz clock Signal from wire 24 bit shift register reference level 0000000111111111100000 CARE workshop on emittance measurements U. Raich CERN AB/BI

  12. New(er) Electronics and Software Treatment • 8 channel flash ADCs 40 MHz, 2kByte memory/channel • Measure during 12 µs (480 profiles of all 24 wires) • Average over 5 profiles • The kicker timing allows us to place the measurement slice of 12 µs anywhere within the 100 us beam pulse • The emittance mountain is plotted in pseudo-colors showing the beam intensities • The emittance mountain is cut in 10% slices to determine the surface containing 67% of the beam (this level can be modified) • The phase space surface is calculated and the corresponding emittance value calculated. • All this is done in the front-end computer CARE workshop on emittance measurements U. Raich CERN AB/BI

  13. Application Program CARE workshop on emittance measurements U. Raich CERN AB/BI

  14. Analyzing Spectrometer + Kicker CARE workshop on emittance measurements U. Raich CERN AB/BI

  15. Slit CARE workshop on emittance measurements U. Raich CERN AB/BI

  16. Spectrometer CARE workshop on emittance measurements U. Raich CERN AB/BI

  17. Transformer CARE workshop on emittance measurements U. Raich CERN AB/BI

  18. SEMGrid CARE workshop on emittance measurements U. Raich CERN AB/BI

More Related