1 / 8

Case study of Wind Energy at National Institute of Technology, Silchar- India

Case study of Wind Energy at National Institute of Technology, Silchar- India. PRESENTED BY Akash Joshi NATIONAL INSTITUTE OF TECHNOLOGY, SILCHAR, ASSAM INDIA. Location of NIT, Silchar. Silchar Latitude : 24° 49’ N Longitude : 92° 46’E Assam, India. Wind data at NIT, Silchar.

omer
Télécharger la présentation

Case study of Wind Energy at National Institute of Technology, Silchar- India

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Case study of Wind Energy at National Institute of Technology, Silchar- India PRESENTED BY Akash Joshi NATIONAL INSTITUTE OF TECHNOLOGY, SILCHAR, ASSAM INDIA

  2. Location of NIT, Silchar Silchar Latitude : 24° 49’ N Longitude : 92° 46’E Assam, India

  3. Wind data at NIT, Silchar • Annual average wind speed is 2.63 m/s • Wind speed is maximum in summer

  4. Savonius Turbine Advantages of S-rotor: 1. Simple and cheap construction 2. Acceptance of wind from any direction thus eliminating the need for reorientation. 3. High starting torque. 4. Relatively low operating speed (rpm)

  5. Analysis • The performance of the machine can be expressed in the form of Power Coefficient (Cp) versus tip-speed ratio (λ). For analysis, the following relations were used:- • Co-efficient of Performance, Cp = Protor/0.5ρV2 • Tip speed ratio (λ) = Velocity of blade tip/Free stream velocity • Graphs showing Cp Vs TSR for different overlapping conditions

  6. Graphs form HOMER • Sample Graphs form HOMER for 3 SAVONIUS Wind Turbine, 1 Battery and 1 inverter of 2kW for above wind data at NIT, Silchar

  7. Conclusion • Wind speed at Silchar is very low • Savonius turbine is the best suitable option • Savonius turbine with 20% overlapping gives the best results. • Co-efficient of Performance at 20% overlapping is 21%

  8. Thank You ! Author : Akash Joshi Contact: akash.joshi@yahoo.com, akash.joshi@rediffmail.com

More Related