1 / 25

WAN Basics Tsunami MP.11 - QB.11

omer
Télécharger la présentation

WAN Basics Tsunami MP.11 - QB.11

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. WAN Basics Tsunami MP.11 - QB.11 QuickBridge 60250 Tsunami MP.11 Rugged Hardware Technical Specifications

    3. MP.11-R Kit contents One radio in rugged weatherproof enclosure Mounting hardware to attach to radio for mounting + Hardware for pole mounting + Hardware for wall mounting One RJ11 to DB9 connector for serial connection (dongle) Cable termination material Installation CD Power Brick and cord

    4. MP.11-R Characteristics Serial port via dongle (also used for Antenna Alignment) New LEDs on Enclosure to check installation/status: Power/Ethernet blinking = powering up, no Ethernet connection Power/Ethernet ON = Powering up, Ethernet OK Wireless blinking = initializing wireless link Wireless ON = WORP link OK The serial connection is made with an RJ-11 to DB-9 connector (also referred to as a dongle). Connect the RJ-11 end to the radio and connect the serial (DB-9) end to your PC to assist you in aligning the antenna and to issue CLI commands. The serial connection is made with an RJ-11 to DB-9 connector (also referred to as a dongle). Connect the RJ-11 end to the radio and connect the serial (DB-9) end to your PC to assist you in aligning the antenna and to issue CLI commands.

    5. MP.11-R Internals

    6. Peltier Element Theory of Operation Peltier element is a thermoelectric device that can push heat in either way, depending on the direction of the current through the device. Solid-state heat pump Operated by electric current Very reliable, no moving parts Heat is transported by the current from one surface to the other. Result: more than 100% efficient heating Electric dissipation + transported heat is pumped through the hot surface of the Peltier

    7. Dynamic Temperature Control Temperature inside the enclosure is not regulated as long as it stays within the 5 .. 50 deg C range (this will result in a difference between internal and external temp of approx 15 20 deg) As soon as internal temperature goes over 50 deg C the enclosure starts cooling, so temp difference drops. When internal temperature goes below 5 deg C the enclosure will start heating, so the internals stay above freezing (0 deg C) When unit is powered while below zero degrees C, it will self-heat and allow the unit to boot up when temperature reaches zero degrees (red LED on).

    8. Internal Unit Temperature The MP.11-R radio board has a digital temperature sensor that can be read via the IIC bus, so the temperature at the PCB level, next to the radio can be monitored. The sample period can be configured in minutes: 1, 5, 10, 15, .., 60. The sampled temp history will be available in a log The log can be exported to a file The duration logged is at least 2 days at 5 min period. A trap will be sent and the temp logged when the temperature approaches the limits by 5 deg C An event will be logged and a trap issued when the temp goes outside the specified range from 0 to +55 deg C

    9. MP.11-R PoE Injector Power Supply providing 48V through Ethernet to power rugged units NOT 802.3af compliant The temperature control needs more power than 802.3af power budget MP.11-R units can not be powered by 802.3af power supply It may run for some time, but eventually will not work MP.11-R Power supply can power other PoE devices (48V 420mA) Connectors on PoE injector: Euro AC (100 .. 240V) Ethernet Data modular plug for LAN Ethernet Data + Power modular plug towards 5054 R/2454 R The unit is equipped with an Active Ethernet module. Using Power-over-Ethernet (PoE), you can provide electricity and wired connectivity to the unit over a single Category 5 cable. Although the power injector that is supplied with the unit is 802.3af-compatible, standard 802.3af-compliant power modules will not properly power the units. Always use the supplied power injector. The Active Ethernet integrated module provides 48 VDC over a standard Cat5 Ethernet cable. Maximum power supplied to the unit is 20 Watts. The units typically draw less than 7.5 Watts. The unit is equipped with an Active Ethernet module. Using Power-over-Ethernet (PoE), you can provide electricity and wired connectivity to the unit over a single Category 5 cable. Although the power injector that is supplied with the unit is 802.3af-compatible, standard 802.3af-compliant power modules will not properly power the units. Always use the supplied power injector. The Active Ethernet integrated module provides 48 VDC over a standard Cat5 Ethernet cable. Maximum power supplied to the unit is 20 Watts. The units typically draw less than 7.5 Watts.

    10. Remote Reload detection The power injector has a Remote Reload button, because the local Reload button is not accessible inside the enclosure. Pressing the Remote Reload button toggles the polarity of the 48V PoE supply lines. Operation is not harmed, because the power supply in the rugged enclosure uses a full-bridge rectifier The polarity reversal is sensed and passed to the MP.11 processor via an opto-coupler The MP.11-R uses the Remote Reload in same way as local Reload: Press button for 5 sec during normal operation deletes config file and resets the unit to factory default configuration. Press button during boot sequence will delete config and image files which brings the unit in Bootloader mode.

    11. 5 & 10MHz Optional Bandwidths The standard channel bandwidth is 20 Mhz for all MP.11 products. MP.11-R provide support for alternative 5 MHz and 10MHz bandwidth channel in addition to the standard 20MHz. Customers can maximize network capacity and allocate bandwidth usage with up to four times greater granularity. Selection of channel bandwidth, turbo-mode (5054-R only), and multicast rate determines the center frequencies available in the drop down selection list, according to the selected country regulatory domain. Roaming is now possible between BSUs with different channel bandwidth configurations.

    12. Channels

    13. Technical Specifications

    14. Technical Specifications

    15. Range calculations

    16. Ethernet cable assembly Cable termination material included in the kit: RJ45 connector plug Weather tight connector cap Liquid-tite fitting Provided cable termination material allows for use of cable of user-required length Completed cable assemblies are available as accessories in three different lengths: 25, 50, 75 meter

    17. Mounting of the radio Screw mounting piece (A) to the back of the radio unit with 4 screws and washers (B) SUs with integrated antenna need to be properly mounted with respect to the antenna polarization (indicated by the arrow on the back of the enclosure)

    18. Mounting of the radio Attach bracket connector (C) to mounting piece (A) with the screw provided This extension piece allows for tilt-adjustments Attach bracket connector (C) to bracket (E) with the nut and screw provided

    19. Mounting of the radio For pole mounting Use bracket (F) and the screws, washers and nuts provided Align bracket (F) and bracket (E) on either end of the pole Insert the screws through the holes in bracket (F) and bracket (E) and tighten the brackets to the pole using the nuts provided For wall mounting Mount bracket (E) directly to the wall using 4 screws (not provided)

    20. MP.11-R Grounding All units should be properly grounded. For MP.11-R, use the hole at the bottom point on the back of each radio and the provided grounding screws to attach a ground wire of at least 10 AWG stranded to each radio.

    21. Antenna Alignment with audio feedback Only implemented on rugged hardware (beeper on daughterboard) Beeping starts when either serial dongle is inserted or CLI command for Antenna Alignment is issued And a WORP link is present. Speed of beeping indicates SNR, longer time between beeps is lower SNR. Using dongle the antenna alignment can be done without holding/monitoring a PC or terminal.

    22. Aligning the antenna The interval between the beeps is based on the average SNR that is recorded During initial alignment when few readings are available a large change in SNR will result a relative small change in the interval between beeps More SNR readings are made impact the average such that a small change in SNR results in a larger change in interval between beeps This allows for fine tuning once getting close to the ideal alignment First do rough alignment Then let the unit settle Then do fine tuning

    23. Tsunami MP.11 5054-R-LR and QB.11 5054-R-LR Similar characteristics to R version, but higher output power Americas (FCC): 5.25-5.35 GHz (15 channels) Americas (FCC): 5.725-5.850 GHz (21 channels) 54, 48, 36, 24, 18, 12, 9, 6, 4.5, 3, 2.25, 1.5 Mbps Output Power: QB version comes with 23 dBi antennas

    24. Tsunami MP.11 5054-R-LR and QB.11 5054-R-LR Rx Sensitivity

    25. Specifications For full Specifications and Accessories go to: Models 5054 R and 2454 R (or go to Proxim Knowledge Base Answer ID 1927 and 1928) Model 5054 R-LR and Model QB.11 5054 R-LR Accessories