1 / 37

Development of GEM-based Digital Hadron Calorimetry Andy White U.Texas at Arlington

Development of GEM-based Digital Hadron Calorimetry Andy White U.Texas at Arlington (for J.Yu, J.Li, M.Sosebee, S.Habib, V.Kaushik). Outline. GEM operation/features First UTA GEM prototype - structure, electronics – results: cosmics, source Multichannel prototype

osanna
Télécharger la présentation

Development of GEM-based Digital Hadron Calorimetry Andy White U.Texas at Arlington

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of GEM-based Digital Hadron Calorimetry Andy White U.Texas at Arlington (for J.Yu, J.Li, M.Sosebee, S.Habib, V.Kaushik) American Linear Collider Workshop Cornell U.

  2. Outline • GEM operation/features • First UTA GEM prototype - structure, electronics – results: cosmics, source • Multichannel prototype • Digital hadronic module ideas • Funding, collaboration American Linear Collider Workshop Cornell U.

  3. Double GEM schematic Create ionization Multiplication Signal induction From S.Bachmann et al. CERN-EP/2000-151 American Linear Collider Workshop Cornell U.

  4. 140mm 70mm GEM foil etching GEM field and multiplication From CERN-open-2000-344, A. Sharma American Linear Collider Workshop Cornell U.

  5. GEM foil hole size American Linear Collider Workshop Cornell U.

  6. GEM operations and features • Simple, robust • Stackable (single, double, triple) • Fast – electron signal  5ns • Relatively low voltage (~400V/foil) • Flexible – almost any anode design • Durable – no aging in extended tests • Gain 102 – 106 American Linear Collider Workshop Cornell U.

  7. Embeded onboard readout Ground to avoid cross-talk Design for DHCAL using Triple GEM American Linear Collider Workshop Cornell U.

  8. First UTA GEM Prototype • Double GEM detector constructed using 10x10 cm2 foils from CERN. • Single 1x2 cm2 anode pad. • Charge preamp, then voltage amp. • Cosmic trigger, small counters, low rate! • Signal verification: no signal with (a) trigger counters displaced from anode pad, (b) air in GEM detector. American Linear Collider Workshop Cornell U.

  9. UTA GEM-based Digital Calorimeter Prototype American Linear Collider Workshop Cornell U.

  10. Anode pad layout 1x2 cm2 pad American Linear Collider Workshop Cornell U.

  11. UTA GEM prototype – high voltage American Linear Collider Workshop Cornell U.

  12. American Linear Collider Workshop Cornell U.

  13. GEM Prototype with preamp/voltage amp American Linear Collider Workshop Cornell U.

  14. Amptek charge pre-amplifier American Linear Collider Workshop Cornell U.

  15. GEM prototype – trigger counters American Linear Collider Workshop Cornell U.

  16. UTA GEM Calorimeter prototype Single cosmic event: upper = trigger, lower = preamp output American Linear Collider Workshop Cornell U.

  17. GEM cosmic signal distribution with Landau fit American Linear Collider Workshop Cornell U.

  18. GEM prototype – source tests • Cs137 source, ~1 MeV electrons • Wall of prototype thinned to allow electrons to reach ionization region of GEM, and use of thin trigger scintillators. • Rate much higher than cosmics! • Used secondary output of charge amplifier to generate ADC gate. • Study signals, noise, gain,… American Linear Collider Workshop Cornell U.

  19. GEM prototype – source tests Source signal Noise American Linear Collider Workshop Cornell U.

  20. Signal Amplitude (mV) Landau Distribution from Cs137 Source American Linear Collider Workshop Cornell U.

  21. GEM/MIP Signal Size Computation • Double GEM – applied 419V/stage • Total Ionization (C): ~93 i.p./cm •  48 e-/MIP (5mm gap) • Double GEM Intrinsic Gain: G • Charge preamp sensitivity (GC) : 0.25 V/e- • Voltage amp. X10 (GV) • Output signal = C x G x GC x GV • Observed ~370mV signal (mean of Landau) •  G = 3100 ± 20% (need better amplifier calibration) American Linear Collider Workshop Cornell U.

  22. Measured UTA GEM Gain UTA Prototype CERN GDD group measurements American Linear Collider Workshop Cornell U.

  23. Multichannel prototype • Next step: a 3 x 3 array of 1 cm2 pads. • Allows one central pad with neighbors for cross-talk tests. • Use a single layer board for simplicity. • Use e.g. HELIX chip for readout. • Anode board built, prototype being reworked. American Linear Collider Workshop Cornell U.

  24. Nine Cell GEM Prototype Readout American Linear Collider Workshop Cornell U.

  25. GEM module ideas • Start from basic TESLA detector layout • Try simple design with GEM “drawers” slid into slots in absorber (formed from plates and spacers). • GEM layer ~6mm, readout layer ?mm. • Readout – amplifier, discriminator, register per channel close to anode pad. Multilayer board with multiple ground planes. • Working on existence proof of readout, services, module boundaries, supports, … American Linear Collider Workshop Cornell U.

  26. American Linear Collider Workshop Cornell U.

  27. American Linear Collider Workshop Cornell U.

  28. TESLA – HCAL Layout American Linear Collider Workshop Cornell U.

  29. DHCAL/GEM Module concepts Use half-size modules w.r.t. TESLA design American Linear Collider Workshop Cornell U.

  30. Design concept for sensitive layer 3mm ionization layer American Linear Collider Workshop Cornell U.

  31. DHCAL-GEM Layer structure • GEM layer -> 6mm • Electronics layer ~3mm • Absorber thickness 16mm x 40 layers • -> ~ 4 interaction lengths for HCAL • - 10x10 mm2 cell size -> ~1.5 x 107 channels for DHCAL-GEM American Linear Collider Workshop Cornell U.

  32. DHCAL/GEM Module concepts End view Side view Bottom view American Linear Collider Workshop Cornell U.

  33. DHCAL/GEM Module concepts GEM layer slides into gap between absorber sheets American Linear Collider Workshop Cornell U.

  34. GEM operation in magnetic field • Electrons drift along E-field lines which are ~radial in the overall detector frame. • However, B-field exists in orthogonal direction. • Forces on electron from E and B ~ equal • -> so…expect ~45 deg. drift. B drift E American Linear Collider Workshop Cornell U.

  35. Funding • DoE ADR funding for year 1 completed -> Prototypes working, many simulation results (see talk by Jae Yu at this meeting) • Request for two more subsequent years of ADR funding • First year of the two funded for ½ student and ½ engineer/postdoc • Equipment funds through ADR + LCRD • Allows us to contemplate construction of a larger size GEM prototype American Linear Collider Workshop Cornell U.

  36. Collaboration • Discussions with Fermilab (Physics dept.) re support for development of: - readout electronics (amplifier, discriminator, …) - electronics “layer” - GEM calorimeter stack for test beam  Agreement (June ’03) to proceed. American Linear Collider Workshop Cornell U.

  37. Conclusions • Built and operated first prototype • Cosmic and source results – gain OK • Multi-channel prototype being built • First ideas on module design • Funding in place for another year • Collaboration with Fermilab agreed. American Linear Collider Workshop Cornell U.

More Related