1 / 13

Prototyping Megaton-Scale n Detectors

This project aims to develop a new scintillator design that is lower in cost, by improving the light output and optical coupling in existing scintillator technologies. A prototype has been constructed and initial results show promising light output. Further research and development is needed to optimize the design and apply for additional funding.

patsyd
Télécharger la présentation

Prototyping Megaton-Scale n Detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prototyping Megaton-ScalenDetectors Developing a New Lower-Cost Scintillator Design • Jason Trevor • DOE Review • July 25, 2007

  2. The Problem • Neutrino and cosmic ray physics continue to require ever larger detectors for measurements of interest. • All existing technologies have limitations • Water Cerenkov – Cheap, but limited by low energy cut-off • Liquid Scintillator – High light yield, but difficult to work with and environmentally hazardous • Solid Scintillator – Many desirable characteristics, but too expensive for use in very large detectors • Water Soluble Scintillator – Highly desirable, but no practical scintillators of this type are currently known • Conclusion: Construction of future large-scale n detectors will require the development of new technologies which will lower unit detector cost.

  3. An idea inspired by MACRO and MINOS Scintillator • In a MINOS scintillator strip, only 5-10% of the light produced actually makes it into the WLS fiber. • There are three main cause of light absorption before the WLS fiber: • Self absorption by the fluors and polystyrene in the scintillator. • Imperfect surface reflectivity. • Absorption through either of the preceding processes after the light has reflected off the fiber/glue/polystyrene interface. WLS Fiber Polystyrene TiO2 Cladding MINOS Scintillator Strip

  4. Plastic Scintillator Granules in Water? • What would happen if granules of plastic scintillator are mixed into water at a 5% concentration with a grid of WLS fibers? • The effective attenuation length of the bulk material is increased by about a factor of 20 • Absorption in the reflector is reduced • A better optical coupling is achieved for light at the WLS fiber boundary • Water is free - Cost per unit mass is reduced by 80-90% (est.) WLS Fibers PMT ~Water Scintillator Granules

  5. Proof of Principle • 19cm x 19cm x 13cm • Constructed using left-over MINOS scintillator and WLS Fiber • Water and scintillator granules were circulated by small pumps • Light output in this prototype was lower than the nominal goal for a practical large detector, but • The scintillator was of poor quality • The prototype was too small… losses were still dominated by absorption in the walls • Solution: Scale up volume by a factor of 200

  6. One Cubic Meter Tank Detector WLS Fibers • Our ADR grant proposal was funded (1yr $48k) • Scintillator strands replaced granules • Easier to extrude high quality scintillator • No circulation system required • More realistic configuration for larger tank detectors • But, more difficult to construct • Construction is complete(with the help of Caltech Undergrads) PMT (A 1 m cube) Scintillator Strands

  7. Detector Construction

  8. Detector Construction

  9. Completed Detector

  10. Readout Topology • Tank is divided into eight regions • All WLS fibers from a given region are routed to one of eight phototube boxes • Muon triggers are centered over the inner four regions • Inner regions are 30cm x 30cm • Muon Triggers are 18cm x 18cm 0 7 1 6 5 2 4 3 1 Meter

  11. A Few Events • Two typical events • Event 897 – Single trigger event – These are mostly muon events • Event 4 – Multiple trigger event – Other stuff (Electrons, hadrons, etc) • Numbers shown are estimated light output in P.E.s – exact calibration still needs to be completed • Preliminary numbers suggest the light output is ~2 – 5 times that of MINOS – A more detailed analysis is necessary to confirm this

  12. Preliminary Analysis 0 1 2 3 4 6 7 5

  13. Summary • Construction of the one cubic meter prototype is complete – undergrad student labor was an essential part of the construction effort • Initial results suggest the light output is 2 – 5 times that of MINOS, but more detailed analysis is necessary • Recent addition of Leon Mualem and Alex Himmel has accelerated progress. • This is a promising new technology • More R&D is necessary – The design is far from optimal • We plan to apply for further ADR funding • A paper is in the works

More Related