An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RAL Update 25/05/2012

  2. SP Stavelet #2 • The best stavelet side yet! • Rumours of “shrinkage” greatly exaggerated: shield pads match sensors well • I blame my plastic ruler... • Cutouts in cover layer slightly offset, but OK • Lengths of some of referencing bonds will be longer than on the existing stavelet • Roy’s design respects HV rules • My scalpel did not... Assembly mock up using module 13 (previously removed from DC-DC Stavelet)

  3. SP Stavelet #1 (CofM 9A) with HV MUX • Leakage • 674uA MUX no sensors • 508uA MUX with sensors • 158uA Sensors only • 9uA discrepancy

  4. Seperate HV feeds: 192.5, 195.0, 197.5, 200.0

  5. HV MUX: 191.9, 194.5, 197.2, 199.9

  6. DTN Seperate HV • Column 0 0 0 1 • Column 1 0 0 0 • Column 2 0 0 1 • Column 3 0 0 34 • Column 4 0 0 0 • Column 5 0 0 0 • Column 6 0 0 16 • Column 7 0 0 113 • Column 8 0 0 16 • Column 9 0 0 2 • Column 10 0 0 35 • Column 11 0 0 75 • Column 12 0 0 188 • Column 13 0 0 60 • Column 14 0 0 86 • Column 15 0 0 396 HV MUX • Column 0 0 0 0 • Column 1 0 0 0 • Column 2 0 0 1 • Column 3 0 0 36 • Column 4 0 0 1 • Column 5 0 0 1 • Column 6 0 0 20 • Column 7 0 0 116 • Column 8 0 0 7 • Column 9 0 0 2 • Column 10 0 0 24 • Column 11 0 0 51 • Column 12 0 0 105 • Column 13 0 0 49 • Column 14 0 0 54 • Column 15 0 0 247

  7. HV MUX: 191.9, 194.5, (0V), 199.9

  8. Comments Comments • HV MUX seems to work well • Noise with 3 on looks slightly higher • If I rerun with 4 on that’s now higher too! • Reproducibility issue, probably not related to MUX Features • Cannot go below voltage of SP+ if one wishes to avoid trips • HV switches can change state if HV supply trips • When HV switches open, can use SHV connectors to measure hybrid “0V” potential