1 / 16

What happens in the aperture?

What happens in the aperture?. Basics of Hematology cell counting. Blood cells. NRBC. EO. RBC. RBC. NEU. MONO. LYM. BASO. PLT. Blood cells – under microscope. Hematology parameters 1. Hematology parameters 2. 1.: RBC-LYM discriminator 2.: LYM-MID discriminator

pgaston
Télécharger la présentation

What happens in the aperture?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What happens in the aperture? Basics of Hematology cell counting

  2. Blood cells

  3. NRBC EO RBC RBC NEU MONO LYM BASO PLT Blood cells – under microscope

  4. Hematology parameters 1

  5. Hematology parameters 2

  6. 1.: RBC-LYM discriminator 2.: LYM-MID discriminator 3.: MID-GRA discriminator 1. 2. 3. Hematology parameters 3

  7. Blood sample

  8. Impedance cell counting principle dR/R = 1 / 20 000 = 50ppm, RBC = 1mV, min PLT= 40µV

  9. Aperture clogging effect

  10. Coincidence effect • >1 cells in aperture look one big cell • Less counts, distorted histogram • Solution: diluting samples, mathematical coincidence correction Linearity range (80um): WBC: 100 x 10^3/ul RBC: 10 x 10^6/ul PLT: 1000 x 10^3/ul

  11. 3. Hemolyser 1. 2. Blood 1:32.000 1:200 Sample preparation: diluting, lysing • a + diluent → b • b + diluent → c → RBC/PLT • b + Lyser → WBC/HGB a b c

  12. PLT & RBC LYM MON GRAN Differential Lysing process RBCs destroyed WBCs selectively shrank to nuclei

  13. & HGB 3-part Differential WBC Histogram

  14. Hemoglobin measuring principle • Specific wavelength light source – green LED @ 560 nm • Light to frequency converter • Ambient light compensation with U/D counting, and light chopping LED SAMPLE DETECTOR LED switching: Frequency output

  15. Hemoglobin calculation – HGB blank • HGB needs blank measurement on clean diluent to compensate temperature drift HGB = C * ln (CNTblank / CNTsample) CNTblank = HGB count on diluent = 10.000 CNTsample = HGB count on sample = 4.000

  16. Thank you for your attention!

More Related