An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Laboratory Measurement of Capillary Pressure

    2. LABORATORY METHODS FOR MEASURING CAPILLARY PRESSURE Porous diaphragm method Mercury injection method Centrifuge method Dynamic method

    3. POROUS DIAPHRAGM METHOD FOR CAPILLARY PRESSURE Laboratory procedure Begin with core saturated with wetting fluid. In addition, saturate the porous disk with same wetting fluid Use pressure to force nonwetting fluid (usually air) into core, thus displacing wetting fluid through the porous disk The pressure difference between the pressure in the nonwetting fluid and the pressure in the wetting fluid equals the capillary pressure Repeat at successively higher pressures until equilibrium is reached (i.e., no more wetting fluid is displaced) Measure wetting phase saturation in core at each pressure increment Laboratory procedure Begin with core saturated with wetting fluid. In addition, saturate the porous disk with same wetting fluid Use pressure to force nonwetting fluid (usually air) into core, thus displacing wetting fluid through the porous disk The pressure difference between the pressure in the nonwetting fluid and the pressure in the wetting fluid equals the capillary pressure Repeat at successively higher pressures until equilibrium is reached (i.e., no more wetting fluid is displaced) Measure wetting phase saturation in core at each pressure increment

    4. CAPILLARY PRESSURE USING POROUS DIAPHRAGM METHOD

    5. COMMENTS ON POROUS DIAPHRAGM METHOD Advantages Very accurate Can use reservoir fluids Disadvantages Very slow (days, weeks, months) Range of capillary pressure is limited by displacement pressure of porous disk Wetting phase of disk should be same as core sample Holes in porous disk act as capillaries, allowing only wetting to flow out until displacement pressure is exceeded

    6. MERCURY INJECTION METHOD FOR CAPILLARY PRESSURE Laboratory procedure Uses mercury as the nonwetting fluid and air (usually under vacuum) as the wetting phase Force mercury into core Measure pressure required to force additional mercury volume into core Calculate mercury saturation (i.e., nonwetting phase saturation) from known injection volumes and known pore volume of core sampleLaboratory procedure Uses mercury as the nonwetting fluid and air (usually under vacuum) as the wetting phase Force mercury into core Measure pressure required to force additional mercury volume into core Calculate mercury saturation (i.e., nonwetting phase saturation) from known injection volumes and known pore volume of core sample

    7. COMMENTS ON MERCURY INJECTION METHOD Advantages Results obtained quickly (minutes,hours) Method is reasonably accurate Very high range of capillary pressures Disadvantages Ruins core / mercury disposal Hazardous testing material (mercury) Conversion required between mercury/air capillary data to reservoir fluid systems

    8. CENTRIFUGE METHOD FOR DETERMINING CAPILLARY PRESSURE Laboratory procedure Similar to porous disk method except centrifugal force (rather than pressure) is applied to fluids in core Pressure (force per unit area) is computed from centrifugal force (which is related to rotational speed of centrifuge) Saturation is computed from fluid removed Laboratory procedure Similar to porous disk method except centrifugal force (rather than pressure) is applied to fluids in core Pressure (force per unit area) is computed from centrifugal force (which is related to rotational speed of centrifuge) Saturation is computed from fluid removed

    9. COMMENTS ON CENTRIFUGE METHOD Advantages Results can be obtained fairly quickly (hours, days, weeks) Reasonably accurate Can use reservoir fluids Disadvantages Complex analysis required can lead to calculation errors

    10. DYNAMIC METHOD OF MEASURING CAPILLARY PRESSURE Laboratory procedure Establish simultaneous steady-state flow of two fluids through core Measure pressures of the two fluids in core using special wetted disks (one porous diaphram wet by cores wetting phase, and one porous diaphram wet by cores non-wetting phase). Difference between the pressure between phases is capillary pressure Saturation is varied by regulating quantity of each fluid entering coreLaboratory procedure Establish simultaneous steady-state flow of two fluids through core Measure pressures of the two fluids in core using special wetted disks (one porous diaphram wet by cores wetting phase, and one porous diaphram wet by cores non-wetting phase). Difference between the pressure between phases is capillary pressure Saturation is varied by regulating quantity of each fluid entering core

    11. COMMENTS ON DYNAMIC METHOD Advantages Simulates reservoir flow conditions Can use reservoir fluids Disadvantages Very tedious to perform (weeks, months) High cost

    12. AVERAGING CAPILLARY PRESSURE DATA USING THE LEVERETT J-FUNCTION The Leverett J-function was originally an attempt to convert all capillary pressure data to a universal curve A universal capillary pressure curve does not exist because the rock properties affecting capillary pressures in reservoir have extreme variation with lithology (rock type) BUT, Leveretts J-function has proven valuable for correlating capillary pressure data within a lithology (see ABW Fig 3-23).

    13. EXAMPLE J-FUNCTION FOR WEST TEXAS CARBONATE Black data are from an original capillary pressure experiments. The blue, red, and green data were for three new experiments, performed to determine the reliability of the original data. The black line represents an average J-function that was initially used in a reservoir simulation study for the field. Ultimately, the rock type was broken into smaller units, and five different capillary pressure relationships were used to represent the ranges of carbonate rock quality observed in the reservoir.Black data are from an original capillary pressure experiments. The blue, red, and green data were for three new experiments, performed to determine the reliability of the original data. The black line represents an average J-function that was initially used in a reservoir simulation study for the field. Ultimately, the rock type was broken into smaller units, and five different capillary pressure relationships were used to represent the ranges of carbonate rock quality observed in the reservoir.

    14. DEFINITION OF LEVERETT J-FUNCTION J(Sw) = Leverett J-function, dimensionless Sw = water saturation, fraction Pc = capillary pressure, psia ? = interfacial tension, dynes/cm ? = contact angle, degrees k = formation permeability, md ? = porosity, fraction J(Sw) = Leverett J-function, dimensionless Sw = water saturation, fraction Pc = capillary pressure, psia ? = interfacial tension, dynes/cm ? = contact angle, degrees k = formation permeability, md ? = porosity, fraction

    15. Pc(Sw) Depends on k,f

    16. LEVERETT J-FUNCTION FOR CONVERSION OF Pc DATA J(Sw) = Leverett J-function, dimensionless Sw = water saturation, fraction Pc = capillary pressure, psia ? = interfacial tension, dynes/cm ? = contact angle, degrees k = formation permeability, md ? = porosity, fraction J(Sw) = Leverett J-function, dimensionless Sw = water saturation, fraction Pc = capillary pressure, psia ? = interfacial tension, dynes/cm ? = contact angle, degrees k = formation permeability, md ? = porosity, fraction

    17. J-function is useful for averaging capillary pressure data from a given rock type from a given reservoir J-function can sometimes be extended to different reservoirs having same lithologies Use extreme caution in assuming this can be done J-function usually not accurate correlation for different lithologies If J-functions are not successful in reducing the scatter in a given set of data, then this suggests that we are dealing variation in rock type USE OF LEVERETT J-FUNCTION