1 / 7

CMS ECAL

CMS ECAL. DAQ Fiber data block format Magnus Hansen 20020226. Protocol Considerations. CMS ECAL FrontEnd is sending one Trigger Tower on one 800Mb optical link to the counting room CIMT protocol is proposed as opposed to 8/10 8/10 more “standard” CIMT considered to be more robust

reidar
Télécharger la présentation

CMS ECAL

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMS ECAL DAQ Fiber data block format Magnus Hansen 20020226

  2. Protocol Considerations • CMS ECAL FrontEnd is sending one Trigger Tower on one 800Mb optical link to the counting room • CIMT protocol is proposed • as opposed to 8/10 • 8/10 more “standard” • CIMT considered to be more robust • GOL used as serialiser • Agilent Technologies G-Link 1034 used as de-serialiser • Some link data format needed Magnus Hansen, CERN-EP/CME

  3. Features • CIMT protocol • Proprietary protocol • Agilent • IEEE standard... • Data word • 16 data bits • Flag bit • Control word • 14 data bits • Idle word • Fill frames • 8-10 protocol • Standard protocol • Data word • 8 data bits • 16 bits sent as two consecutive words • Idle word • Fill frames • Commas etc. Magnus Hansen, CERN-EP/CME

  4. Local BCID Control word “01” 12 bits Local EVID Control word “10” 12 bits Global triggers Laser triggers Monitoring triggers Channel ID Control word “00” 3 bit channel (1-5) 3 bit strip (1-5) 7 bits tower (1-68) parity? Sample Data word 12 bit ADC data 2 bit FPPA gain 1 bit monitoring flag 1 bit forced gain flag Parity (flag bit) Checksum Control word “11” Vertical XOR Other Idle word Fill frame CIMT Data link formatword definition Magnus Hansen, CERN-EP/CME

  5. CIMT DAQ link data block format • CIMT protocol • One tower event • BCID • EVID • 1 tower sum • 25 channels • 1 channel header • 10 samples / channel • Checksum • N.o. clock cycles • 4 + (10 + 1) * 25 = 279 cp • 6.975 us Magnus Hansen, CERN-EP/CME

  6. Idle word Fill frame Local BCID Control word “01” 12 bits BCID 2 bits “01” Forced gain flag Local EVID Control word “10” 12 bits EVID Global triggers Laser triggers Monitoring triggers 2 bits “10” Forced gain bit Channel ID Control word “00” 3 bit channel (1-5) 3 bit strip (1-5) 7 bits tower (1-68) parity? Sample Data word 12 bit ADC data 2 bit FPPA gain 1 bit monitoring flag Checksum Control word “11” Vertical XOR Other 8-10 Data link formatword definition Magnus Hansen, CERN-EP/CME

  7. DAQ link data block format • 8-10 protocol • One tower event • BCID • EVID • 1 tower sum • 25 channels • 1 channel header • 10 samples / channel • Checksum • N.o. clock cycles • 4 + (10 + 1) * 25 = 279 cp • 6.975 us • No Parity Magnus Hansen, CERN-EP/CME

More Related