1 / 69

New Measurement of the Electron Magnetic Moment and the Fine Structure Constant

New Measurement of the Electron Magnetic Moment and the Fine Structure Constant. Gerald Gabrielse Leverett Professor of Physics Harvard University. Almost finished student: David Hanneke Earlier contributions: Brian Odom, Brian D’Urso, Steve Peil,

saxon
Télécharger la présentation

New Measurement of the Electron Magnetic Moment and the Fine Structure Constant

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Measurement of the Electron Magnetic Momentand the Fine Structure Constant Gerald Gabrielse Leverett Professor of Physics Harvard University Almost finished student: David Hanneke Earlier contributions: Brian Odom, Brian D’Urso, Steve Peil, Dafna Enzer, Kamal Abdullah Ching-hua Tseng Joseph Tan 2006 DAMOP Thesis Prize Winner 20 years 6.5 theses N$F 0.1 mm

  2. Recent Back-to-Back Papers New Measurement of the Electron Magnetic Moment B. Odom, D. Hanneke, B. D’Urson and G. Gabrielse, Phys. Rev. Lett.97, 030801 (2006). New Determination of the Fine Structure Constant G. Gabrielse, D. Hanneke, T. Kinoshita, M. Nio, B. Odom, Phys. Rev. Lett. 97, 030802 (2006). • AIP Physics Story of the Year (Phys. News Update, 5 Dec. 2006) • Science 313, 448-449 (2006) • Nature 442, 516-517 (2006) • Physics Today, 15-17 (August, 2006) • Cern Courier (October 2006) • New Scientist 2568, 40-43 (2006) • Physics World (March 2007)

  3. Why Does it take Twenty Years and 6.5 Theses? Explanation 1: Van Dyck, Schwinberg, Dehemelt did a good job in 1987! Phys. Rev. Lett. 59, 26 (1987) Explanation 2a: We do experiments much too slowly Explanation 2b: Takes time to develop new ideas and methods needed to measure with 7.6 parts in 1013 uncertainty • One-electron quantum cyclotron • Resolve lowest cyclotron states as well as spin • Quantum jump spectroscopy of spin and cyclotron motions • Cavity-controlled spontaneous emission • Radiation field controlled by cylindrical trap cavity • Cooling away of blackbody photons • Synchronized electrons identify cavity radiation modes • Trap without nuclear paramagnetism • One-particle self-excited oscillator first measurement with these new methods

  4. The New Measurement of Electron g U. Michigan beam of electrons spins precess with respect to cyclotron motion Harvard one electron quantum cyclotron motion resolve lowest quantum levels cavity-controlled radiation field (cylindrical trap) U. Washington one electron observe spin flip thermal cyclotron motion 100 mK self-excited oscillator inhibit spontan. emission cavity shifts Dehmelt, Van Dyck Crane, Rich, …

  5. Magnetic Moments, Motivation and Results

  6. Bohr magneton Magnetic Moments angular momentum magneticmoment e.g. What is g for identical charge and mass distributions? 

  7. Bohr magneton Magnetic Moments angular momentum magneticmoment identical charge and mass distribution spin for Dirac point particle simplest Dirac spin, plus QED (if electron g is different  electron has substructure)

  8. Why Measure the Electron Magnetic Moment? • Electron g - basic property of simplest of elementary particles • Determine fine structure constant – from measured g and QED (May be even more important when we change mass standards) • Test QED – requires independent a • Test CPT – compare g for electron and positron  best lepton • test • Look for new physics beyond the standard model • Is g given by Dirac + QED? If not  electron substructure • (new physics) • Muon g search needs electron g measurement

  9. spin magneticmoment Bohr magneton New Measurement of Electron Magnetic Moment • First improved measurement since 1987 • Nearly six times smaller uncertainty • 1.7 standard deviation shift • Likely more accuracy coming • 1000 times smaller uncertainty than muon g B. Odom, D. Hanneke, B. D’Urso and G. Gabrielse, Phys. Rev. Lett. 97, 030801 (2006).

  10. 0 85 (76) (more digits coming)

  11. Dirac + QED Relates Measured g and Measured a Dirac point particle weak/strong Sensitivity to other physics (weak, strong, new) is low Measure QED Calculation Kinoshita, Nio, Remiddi, Laporta, etc. • Use measured g and QED to extract fine structure constant • Wait for another accurate measurement of a  Test QED

  12. Basking in the Reflected Glow of Theorists 2004 Remiddi Kinoshita G.G

  13. theoretical uncertainties experimental uncertainty

  14. New Determination of the Fine Structure Constant • Strength of the electromagnetic interaction • Important component of our system of • fundamental constants • Increased importance for new mass standard • First lower uncertainty • since 1987 • Ten times more accurate than • atom-recoil methods G. Gabrielse, D. Hanneke, T. Kinoshita, M. Nio, B. Odom, Phys. Rev. Lett. 97}, 030802 (2006).

  15. Widely Re-Reported Science Nature Physics Today New Scientist Cern Courier … Fox News Moral: what is quoted is not necessarily what was said

  16. Next Most Accurate Way to Determine a (use Cs example) Combination of measured Rydberg, mass ratios, and atom recoil Haensch, … Pritchard, … Chu, … Haensch, … Tanner, … Werthe, Quint, … (also Van Dyck) • Now this method is 10 times less accurate • We hope that will improve in the future  test QED Biraben, … (Rb measurement is similar except get h/M[Rb] a bit differently)

  17. Earlier MeasurementsRequire Larger Uncertainty Scale ten times larger scale to see larger uncertainties

  18. Test of QED Most stringent test of QED: Comparing the measured electron g to the g calculated from QED using an independent a • The uncertainty does not comes from g and QED • All uncertainty comes from a[Rb] and a[Cs] • With a better independent a could do a ten times better test

  19. From Freeman Dyson – One Inventor of QED Dear Jerry, ... I love your way of doing experiments, and I am happy to congratulate you for this latest triumph.  Thank you for sending the two papers. Your statement, that QED is tested far more stringently than its inventors could ever have envisioned, is correct.  As one of the inventors, I remember that we thought of QED in 1949 as a temporary and jerry-built structure, with mathematical inconsistencies and renormalized infinities swept under the rug.  We did not expect it to last more than ten years before some more solidly built theory would replace it.  We expected and hoped that some new experiments would reveal discrepancies that would point the way to a better theory. And now, 57 years have gone by and that ramshackle structure still stands. The theorists … have kept pace with your experiments, pushing their calculations to higher accuracy than we ever imagined. And you still did not find the discrepancy that we hoped for.  To me it remains perpetually amazing that Nature dances to the tune that we scribbled so carelessly 57 years ago.  And it is amazing that you can measure her dance to one part per trillion and find her still following our beat. With congratulations and good wishes for more such beautiful experiments, yours ever, Freeman.

  20. Direct Test for Physics Beyond the Standard Model • Is g given by Dirac + QED? If not  electron substructure Does the electron have internal structure?Brodsky, Drell, 1980 limited by the uncertainty in independent a values if our g uncertainty was the only limit Not bad for an experiment done at 100 mK, but LEP does better LEP contact interaction limit

  21. Muon Test for Physics Beyond the Standard ModelNeeds Measured Electron g less accurately measured than we measure electron g by a factor of 1000 expected to be bigger than for electron by ~40,000 big contribution must be subtracted out need a need test the QED calculation of this large contribution  Muon search for new physics needs the measurement of the electron g and a

  22. Could We Check the 3sDisagreementbetween Muon g Measurement and “Calculation”? • (mm/me)2 ~ 40,000  muon more sensitive to “new physics” • ÷1,000  how much more accurately we measure • ÷ 3  3s disagreement is now seen  If we can reduce the electron g uncertainty by 13 times more should be able to have the precision to see the 3s effect (or not) Also need: • QED and SM calculations improved by factor of ~5 • Independent measurement of a improved by factor of 130 These are large numbers  hard to imagine that this will happen quickly

  23. How Does One Measure the Electron gto 7.6 parts in 1013?

  24. How to Get an Uncertainty of 7.6 parts in 1013 • One-electron quantum cyclotron • Resolve lowest cyclotron as well as spin states • Quantum jump spectroscopy of cyclotron and spin motions • Cavity-controlled spontaneous emission • Radiation field controlled by cylindrical trap cavity • Cooling away of blackbody photons • Synchronized electrons probe cavity radiation modes • Elimination of nuclear paramagnetism • One-particle self-excited oscillator first measurement with these new methods Make a “Fully Quantum Atom” for the electron Challenge: An elementary particle has no internal states to probe or laser-cool  Give introduction to some of the new and novel methods

  25. Basic Idea of the Measurement Quantum jump spectroscopy of lowest cyclotron and spin levels of an electron in a magnetic field

  26. n = 4 n = 3 n = 2 0.1 mm n = 1 n = 0 2 y Need low temperature cyclotron motion T << 7.2 K 0.1 mm One Electron in a Magnetic Field

  27. First Penning Trap Below 4 K  70 mK Need low temperature cyclotron motion T << 7.2 K

  28. David Hanneke G.G.

  29. Electron Cyclotron Motion Comes Into Thermal Equilibrium T = 100 mK << 7.2 K  ground state always Prob = 0.99999… electron cold hot cavity blackbody photons spontaneous emission

  30. 0.23 0.11 0.03 9 x 10-39 Electron in Cyclotron Ground State QND Measurement of Cyclotron Energy vs. Time average number of blackbody photons in the cavity On a short time scale  in one Fock state or another Averaged over hours  in a thermal state S. Peil and G. Gabrielse, Phys. Rev. Lett. 83, 1287 (1999).

  31. n = 4 n = 3 n = 4 n = 2 n = 3 n = 1 n = 2 n = 0 n = 1 n = 0 Spin  Two Cyclotron Ladders of Energy Levels Cyclotron frequency: Spin frequency: ms = -1/2 ms = 1/2

  32. n = 4 n = 3 n = 4 n = 2 n = 3 n = 1 n = 2 n = 0 n = 1 n = 0 Basic Idea of the Fully-Quantum Measurement Cyclotron frequency: Spin frequency: ms = -1/2 ms = 1/2 B in free space Measure a ratio of frequencies: • almost nothing can be measured better than a frequency • the magnetic field cancels out (self-magnetometer)

  33. n = 4 n = 3 n = 4 n = 2 n = 3 n = 1 n = 2 n = 0 n = 1 n = 0 Special Relativity Shift the Energy Levels d Cyclotron frequency: Spin frequency: ms = -1/2 ms = 1/2 Not a huge relativistic shift, but important at our accuracy Solution: Simply correct for d if we fully resolve the levels (superposition of cyclotron levels would be a big problem)

  34. Cylindrical Penning Trap • Electrostatic quadrupole potential  good near trap center • Control the radiation field  inhibit spontaneous emission by 200x (Invented for this purpose:G.G. and F. C. MacKintosh; Int. J. Mass Spec. Ion Proc. 57, 1 (1984)

  35. One Electron in a Penning Trap • very small accelerator • designer atom 200 MHz detect cool 12 kHz need to measure for g/2 153 GHz Electrostatic quadrupole potential Magnetic field

  36. Solution: Brown-Gabrielse invariance theorem Frequencies Shift • Imperfect Trap • tilted B • harmonic • distortions to V Perfect Electrostatic Quadrupole Trap B in Free Space not a measurable eigenfrequency in an imperfect Penning trap Problem:

  37. Spectroscopy in an Imperfect Trap • one electron in a Penning trap • lowest cyclotron and spin states expansion for To deduce g  measure only three eigenfrequencies of the imperfect trap

  38. Detecting and Damping Axial Motion measure voltage V(t) I2R damping Axial motion 200 MHz of trapped electron self-excited oscillator feedback amplitude, f

  39. Feedback Cooling of an Oscillator Electronic Amplifier Feedback: Strutt and Van der Ziel (1942) Basic Ideas of Noiseless Feedback and Its Limitations: Kittel (1958) Applications: Milatz, … (1953) -- electrometer Dicke, … (1964) -- torsion balance Forward, … (1979) -- gravity gradiometer Ritter, … (1988) -- laboratory rotor Cohadon, … (1999) -- vibration mode of a mirror Proposal to apply Kittel ideas to ion in an rf trap Dehmelt, Nagourney, … (1986)  never realized Proposal to “stochastically” cool antiprotons in trap Beverini, … (1988) – stochastic cooling  never realized Rolston, Gabrielse (1988) – same as feedback cooling (same limitations) Realization of feedback cooling with a trapped electron (also include noise) D’Urso, Odom, Gabrielse, PRL (2003) D’Urso, Van Handel, Odom, Hanneke, Gabrielse, PRL 94, 11302 (2005) faster damping rate  higher temperature

  40. QND Detectionof One-Quantum Transitions one-electron self-excited oscillator n=0 cyclotron ground state n=1 cyclotron excited state n=0 cyclotron ground state n=1 n=0 time

  41. QND Quantum Non-demolition Measurement B H = Hcyclotron + Haxial+ Hcoupling QND condition [ Hcyclotron, Hcoupling ] = 0 QND: Subsequent time evolution of cyclotron motion is not altered by additional QND measurements

  42. B Observe Tiny Shifts of the Frequencyof a One-Electron Self-Excited Oscillator one quantum cyclotron excitation spin flip Unmistakable changes in the axial frequency signal one quantum changes in cyclotron excitation and spin "Single-Particle Self-excited Oscillator" B. D'Urso, R. Van Handel, B. Odom and G. Gabrielse Phys. Rev. Lett. 94, 113002 (2005).

  43. Emboldened by the Great Signal-to-Noise Make a one proton (antiproton) self-excited oscillator • try to detect a proton (and antiproton) spin flip • measure proton spin frequency • we already accurately measure antiproton cyclotron frequencies • get antiproton g value • Hard:nuclear magneton is 500 times smaller • Experiment underway  Harvard •  also Mainz and GSI (without SEO) • (build upon bound electron g values) (Improve by factor of a million or more)

  44. t= 16 s Need Averaging Time to Observe a One-quantum Transition  Cavity-Inhibited Spontaneous Emission Application of Cavity QED excite, measure time in excited state

  45. Cavity-Inhibited Spontaneous Emission Free Space B = 5.3 T Within Trap Cavity Inhibited By 210! B = 5.3 T cavity modes Purcell Kleppner Gabrielse and Dehmelt frequency

  46. “In the Dark” Excitation  Narrower Lines • Turn FET amplifier off • Apply a microwave drive pulse of ~150 GH • (i.e. measure “in the dark”) • Turn FET amplifier on and check for axial frequency shift • Plot a histograms of excitations vs. frequency Good amp heat sinking, amp off during excitation Tz = 0.32 K

  47. n = 2 n = 3 n = 1 n = 2 n = 0 n = 1 n = 0 ms = 1/2 ms = -1/2 Big Challenge: Magnetic Field Stability Magnetic field cancels out But: problem when B drifts during the measurement Magnetic field take ~ month to stabilize

  48. Self-Shielding Solenoid Helps a Lot Flux conservation  Field conservation Reduces field fluctuations by about a factor > 150 “Self-shielding Superconducting Solenoid Systems”, G. Gabrielse and J. Tan, J. Appl. Phys. 63, 5143 (1988)

  49. Eliminate Nuclear Paramagnetism • Deadly nuclear magnetism of copper and other “friendly” materials • Had to build new trap out of silver • New vacuum enclosure out of titanium ~ 1 year setback

More Related