1 / 40

Air & Draft system

Air & Draft system. www.powerpointpresentationon.blogspot.com. Presentation Plan. Various auxiliary equipments in a boiler Need for Draft System Primary and secondary air system in Boiler and their fans Other fans in a boiler Basic of fans: Fan Types and selection

seanna
Télécharger la présentation

Air & Draft system

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Air & Draft system www.powerpointpresentationon.blogspot.com

  2. Presentation Plan • Various auxiliary equipments in a boiler • Need for Draft System • Primary and secondary air system in Boiler and their fans • Other fans in a boiler • Basic of fans: Fan Types and selection • Fan laws and factors affecting fan performance • Performance curves

  3. Arrangement of Boiler Auxiliaries

  4. Combustion Air Flue Gases Need of Draft System Boiler • Air needed for combustion • Flue are needed to be evacuated • Losses due to flow need to be overcome

  5. How to select a fan • Air or Gas flow -Kg/hr • Density (function of temperature and pressure) • System resistance (losses) Major Fans in Boiler Draft System • PA Fans • FD Fans • ID Fans

  6. PRIMARY AIR/MILL SEAL AIR SYSTEM • Ambient air is drawn into the primary air ducting by two 50% duty, motor driven axial reaction fans. • Air discharging from each fan is divided into two parts, one passes first through a air pre-heater then through a gate into the P.A bus duct. The second goes to the cold air duct. The mix of both is used to carry the pulverized coal to the boiler.

  7. Components of PA Fan • Suction Bend With volume Measurement instruments • Fan housing with Guide Vanes • Main Bearings (Anti Friction) • Rotor with impeller with adjustable blade with pitch control • Guide vane housing with guide vanes • Diffuser with pressure measurement instruments

  8. SECONDARY AIR SYSTEM • Ambient air is drawn into the secondary air system by two 50% duty, motor driven axial reaction forced draft fans with variable pitch control. • Air discharging from each fan passes first through a air preheated then through a isolating damper into the secondary air bust duct. • The cross over duct extends around to each side of the boiler furnace to form two secondary air to burner ducts. • At the sides of the furnace, the ducts split to supply air to two corners. Then split again to supply air to each of nineteen burner/air nozzle elevations in the burner box.

  9. Burner Box Dampers • Coal/Air Dampers • Secondary Air Dampers • Oil/Secondary Air Dampers • Bottom Tier Secondary Air Damper • Over Fire Damper

  10. Primary and Secondary air System in the Boiler

  11. Axial Fans FD Application

  12. Induced Draft System • There are three induced draught fans per boiler, two operating and one standby • In 500 MW fans are single-stage, double-inlet centrifugal fans. Principal fan elements of the fan are: • Housing • Inlet dampers • Rotor with Bearing • Shaft Seal

  13. ID Fan • The rotor consists of shaft and assembled impeller and runs in two sleeve bearings that are arranged outside of the housing. • The impeller consists of a centre disc and two cover discs that are reinforced by forged rings. The bent blades are welded into position between the impeller discs. • The blades are protected by screwed - on wear plates. • The shaft is of hollow design. The fan shaft has been rated so that max. operating speed is below the critical speed. Impeller and shaft are connected by means of a flange. This screwing is protected by wear plates. • The fan housing is sealed by means of two-part labyrinth seals. • Bearings are lubricated with oil.

  14. Other Fans in The System • Ignitor Air Fan: Provide combustion air to the ignitors. Take suction air from the atmosphere and supplies air to the ignitor wind box. • Scanner Air Fan: Supplies cooling air to flame scanners. Normally there are two fans taking suction from FD Fan discharge duct. • Mill Seal air fan: Seal air fans provide air for the sealing of Mill bearing. Suction is from cold Primary air and pressure is boosted up to maintain the differential pressure

  15. AIR AND FLUE GAS PATH TYPICAL 500 MW BOILER TO MILLS PAPH-A PA FAN -A SCAPH-A PRIMARY ECO BYPASS TO ESP AEROFOIL SCAPH-A SECOND SAPH-A AA203 AA202 AA205 AA201 AA204 FD FAN -B HOT SA HDR HOT PA HDR DIVISION PANELETTE S.H ECONOMISER -1 ECONOMISER -2 RE HEATER ECONOMISER-3 PLATEN S.H HORIZONTAL S.H COMBUSTION CHAMBER AA204 AA201 AA205 AA203 AA202 SAPH-B FD FAN-A SCAPH-B SECOND AEROFOIL ECO BYPASS TO ESP COLD SEC. AIR BIPLANE DAMPER COLD PRIM AIR SCAPH-B PRIMARY DIVERTER DAMPER HOT PRIMARY AIR HOT SEC. AIR PAPH-B FLUE GAS PNEUMATICALLY O/P KNIFE EDGE GATE TO MILLS MOTOR O/P LOUVER DAMPER PA FAN -A PNEUMATICALLY O/P LOUVER DAMPER MOTOR O/P GATE

  16. Scheme of Air and Gas Path

  17. ID Fan at Location

  18. Variation of Pressure in Boiler

  19. Basics on Fans

  20. Equipment Specific Ratio Pressure rise (mm wcl) Fans Up to 1.11 1136 Blowers 1.11 to 1.20 1136 – 2066 Compressors more than 1.20 - Difference between fans, blowers and compressors As per ASME the specific pressure, i.e, the ratio of the discharge pressure over the suction pressure is used for defining the fans, blowers and compressors as highlighted below :

  21. Typical centrifugal fan operation

  22. Fan types Axial fan Centrifugal fan

  23. Centrifugal Fan: Types Paddle Blade (Radial blade) Forward Curved (Multi vane) Backward Curved

  24. Axial Flow Fan: Types

  25. Fan Types and Efficiencies

  26. System characteristic curve

  27. System curve

  28. Fan Laws

  29. Fan static pressure Fan Static Pressure r SP = SP (Fan outlet) – SP (Fan inlet) SP (Fan outlet) – Static pressure at fan outlet, mm WC SP (Fan inlet) – Static pressure at fan inlet, mm WC r SP = 0.05 – (-10) = 10.05 mm W.C.

  30. Speed vs Power

  31. Flow control • Damper - Most Popular • Variable Speed Drive Recirculation Damper 100 VFC Power 75 50 VFD 25 Ideal 25 50 75 100 Flow

  32. Impact of speed reduction

  33. Use of VSD: Boiler ID fan case study

  34. Use of VSD: Boiler ID fan case study (contd.)

  35. THANK YOU