EMU Slice Test Run Plan

EMU Slice Test Run Plan. a working document. CSC position at YE-2 On-chamber electronics available Life support is available HV+LV: TB equipment gas: T-ed of the test-B supply Off-chamber electronics enough VME modules for 3 chambers in two crates TMB, DMB, CCB and MPC

senona
Télécharger la présentation

EMU Slice Test Run Plan

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMU Slice Test Run Plan a working document

  2. CSC position at YE-2 On-chamber electronics available Life support is available HV+LV: TB equipment gas: T-ed of the test-B supply Off-chamber electronics enough VME modules for 3 chambers in two crates TMB, DMB, CCB and MPC VME backplanes are shipped from UF dynatem orders are placed trigger & clock distribution TTCvi, TTCvx/ex and 6U rack unavailable VME controller temporary replacement TF electronics available SP, CCB, back plane 9U rack + VME controller controllers are ordered control & daq PC is available to be equipped with SBS controllers for TF and TTC crates Executive Summary / Status Details on the following pages

  3. choice of CSC location • station: YE-2 • 100% completed • YE+ stations will be lowered first • more time for testing • close to DAQ room • not relevant at this moment, but expected to be of importance for the CMS SliceTest • close to DCS test stand • allow near future integration • towards USCMS Slice Tests • both DAQ and HCAL preferences are relevant • HCAL’s preference not clear • the success of EMU Slice Test would be that this is not an issue: provided we have “CSC life support” any set of chambers should be configurable on a (very) short time scale.

  4. CSC Life Support • HV • test beam CAEN PS will be hooked up • possibly adding a win-xp control PC • LV • test beam LV supplies can be used • 4 pairs available • gas • T-ed of the gas supply for test B

  5. On-chamber electronics • all chambers on station -2 are fully installed • what chambers have skewclear cables routed • target chambers should be ready • accessibility • unable to get at CFEB for back chambers • unable to get the LV boards • cover plates can not be removed • ALCT can be reached • provided the disks are not closely packed

  6. Off-chamber electronics • Peripheral Crate (PC) • mini-rack is installed • hosts max. 2 PCs • space for std. VME crate (Electronics Pool) • max. 1 per mini-rack

  7. Peripheral Crate • Back plane • use std. VME crate for old and previous production prototype • cooling: fans • sticks out ~10-20cm • no an issue • use new crate for new prod.-type backplane • this involves a non-standard or new power supply • new PS will not be available soon • cooling: hook up to water manifold • new production type backplane will not be available soon • use new crate with temporary fix for the PS • cooling: separate tray of fans

  8. Electronics • VME controller • Dynatem D360 • should come with the back plane • lack of dynatems • two new D360s are ordered • New prototype (OSU) • different ethernet connections • optical Gb • impact on software • HAL support?

  9. Electronics (cont’d) • TMB • 4 TMB2004 at CERN • DMB • 3 DMBs at CERN • CCB • CCB’01: one TF-prepared version at CERN • CCB’04: 2 at CERN • MPC: • 1 at CERN

  10. Trigger & Clock Distribution • TTCvi + TTCvx(ex) • requires dedicated 6U crate • use the new CERN/CMS standard: CAEN VME controller • two controllers will be ordered • availability? • none found so far • NIM rack • rack • modules: • scintillator trigger • discriminators, coincidence units, fan-out, HV supplies • TF trigger • ECL translator • all available from TestBeam equipment • CERN E-pool • Fibers • enough for initial TTCvx set-up • Alternative Solution • run without TTC branch and rely on CCB clock only • allows us to start e.g. timing and calibration procedures

  11. DAQ Electronics • DDU/DCC • initially using the old DDU • hosted in the PeripheralCrate, no need for a special crate + controller • when available use the EmuFED crate • DDU/DCC/backplane/controller • minor software effort • old/new DDU can take up to 15 inputs • some defect channels are documented • DAQ pc has Gbit ethernet card and software • previously used at TestBeam

  12. TF electronics • MPC • in the PeripheralCrate • only one module at CERN • need more when adding crates • not urgent • TF backplane and SP • currently on loan to the Vienna group • should be available by the end of November’04 • crate + VME controller • crate unavailable (E-Pool) • VME controller will be ordered (CAEN) • specially prepared CCB at CERN (currently on loan to Vienna group) • MS • no real need for MS

  13. Additional Requirements • The system should be using SP triggers as soon as possible • However, to bootstrap the system a scintillator based trigger may proof to be useful • Requirements • NIM logic and NIM HV supplies • scintillators + mounting structure