1 / 6

Hybrid Power Compensation | Reactive Compensation System

Hybrid Reactive Power Compensation System for Low Voltage Applications. It is used as a new generation of compensation module with functions of energy saving, reduction of line loss, power factor enhancement and improvement of power quality.

sfereelect
Télécharger la présentation

Hybrid Power Compensation | Reactive Compensation System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. About Reactive Compensation Reactive compensation improves grid power factor in power supply system. It also reduces the power loss of transformer and transmission line. It improves power efficiency and the environment.So the reactive power compensation device plays an important role in the power supply system. Improper selection or use of compensation device will cause many factors such as harmonic increase and voltage swell or dip.

  2. Advantages of Reactive Compensation • Stabilize the voltage of power grid and improve power quality • Improve power factor, reduce capacity and equipment investment • Reduce line loss, improve the transmission capacity of active power • Balance the active power and reactive power of three-phase power grid • Reduce the loss of transformer, improve the utilization of transformer.

  3. Schematic Analysis of Reactive Compensation • Reactive power Q1↓Apparent S1↓ Total currentI1↓ active power P not change • Power factor COSΦ↑=P(not change)/S↓ • Since reactive power Q1↓ with apparent S1Q1↓ total current I1Q1↓ active power is unchanged • Power factor COSΦ↑=P( unchanged)/ S↓

  4. Economical Advantage of Reactive Compensation One factory transformer is 2000kVA, power factor is 0.85 at present, loading rate is 80%, target improved power factor is 0.95, how much economic benefits will it take? Bill calculation Power factor 0.85=Bill forfeit(2.5%) Power factor 0.95(or 1)=Bill reward(0.75%) Average unit price = 1usd/degree Annual forfeit before compensation=2000×0.85×0.8x24x30x12x1x2.5%=293,000 usd Annual reward after compensation=2000×0.95×0.8x24x30x12x1x0.75%=99,000 usd Total billing: 293,000 99,000=392,000usd

  5. Contact US Address : - Dongding Road 1, Wuxi Jiangsu, 214437, China Email - sales@sfere-elec.com Call - 0510 8619 9063 Visit - https://www.sfere-elec.net/

More Related