An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Photo cathode requirements for the European XFEL WSHQE Oct. 5, 2006 Klaus Floettmann WSHQE, OCT. 5, 2006

  2. A lifetime of some month with a QE > 0.5% is required. This is achieved with Cs2Te Cathodes e.g. at Flash. Can we go home now? QE and Lifetime requirements WSHQE, OCT. 5, 2006

  3. roughly half of the predicted emittance of the XFEL injector is due to the thermal emittance of the cathode Problem I: WSHQE, OCT. 5, 2006

  4. Development of the transverse Emittance • 1nC charge • uniform transverse distribution • longitudinal flat-top with 2 ps rise time • incl. thermal emittance WSHQE, OCT. 5, 2006

  5. Slice Emittance at the Injector exit emittance in longitudinal slices of the bunch WSHQE, OCT. 5, 2006

  6. Slice Emittance at the Injector exit w.o. thermal emittance WSHQE, OCT. 5, 2006

  7. The measured thermal emittance is even higher than expected from simple theoretical predictions (Schottky effect, cathode roughness) How can we reduce the thermal emittance? reduce cathode roughness control the work function …? WSHQE, OCT. 5, 2006

  8. dark current presents a sever operational problem for the XFEL injector Problem II: WSHQE, OCT. 5, 2006

  9. Dark Current extrapolation to 60 MV/m no conditioning effect taken into account WSHQE, OCT. 5, 2006

  10. A large fraction of the dark current is generated at or near the cathode. Collimation at low energies is very difficult because the dark current has similar properties as the beam How can we reduce the dark current generation reduce cathode roughness reduce number of emitters by better cleaning techniques …? WSHQE, OCT. 5, 2006

  11. Dry Ice Cleaning Principle cold Nitrogen CO2 WSHQE, OCT. 5, 2006

  12. CO2 Nozzle WSHQE, OCT. 5, 2006

  13. No field emission was observed up to 90 MV/m on dry ice cleaned Cu samples in field emission scans. Dry ice cleaning of the gun cavity is in preparation. Dry Ice Cleaning of the cathode plugs should be tested next. To monitor the deposition of field emitters during the cathode preparation process a field emission scanning apparatus for the cathodes will be designed and build in collaboration with the University of Wuppertal. WSHQE, OCT. 5, 2006