1 / 13

Micropipettes

Micropipettes. Measuring volumes which are what we scientists call “very, very small”. MICROPIPETTE RULES. Don’t set the pipettes past their intended range (high or low), even though you can – set the pipette volume only within the range specified for that micropipette

Télécharger la présentation

Micropipettes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Micropipettes Measuring volumes which are what we scientists call “very, very small”

  2. MICROPIPETTE RULES • Don’t set the pipettes past their intended range (high or low), even though you can – set the pipette volume only within the range specified for that micropipette • P-20 range is 2 – 20 ul • P-100 range is 20 – 100 ul • P-200 range is 20 – 200 ul • P-1000 range is 200 – 1000 ul

  3. When using a micropipette, first apply a tip. • Check to be sure the tip is on securely. • Only open the tip box when getting a tip – DON’T LEAVE IT OPEN!

  4. NEVER hold pipette so that the tip is higher than the handle or liquid leaks into the barrel (BAD!) • Always hold pipettes vertically • when in use.

  5. Feel the stops before you begin taking up or dispensing any liquid. 1st stop: Exact volume to which the pipette is set. Press to this stop before immersing pipette tip in the desired solution. 2nd stop: Use when dispensing solution. Pushes an extra volume of air to dislodge any solution adhering to the tip.

  6. How to pipette

  7. Extract and dispense SLOWLY. • When taking up or dispensing • liquid, don’t put the tip any deeper • into the liquid than necessary. • When dispensing, touch the tip • to the side or bottom of the tube, • or if there is liquid already in the • tube, touch the tip to the liquid.

  8. Mid-range: 2 - 20 µL 10 -100 µL 20 - 200 µL Range is printed on the button or on the side Use medium sized yellow tips

  9. We will be using P-20 and P-200 pipettes P-20 has a range of 2 - 20 µL Digits represent Tens (10’s) Ones (1’s) Tenths (1/10’s)

  10. 10 -100 µL This pipette is set to its maximum: 100 µL Digits represent: 100’s 10’s 1’s

  11. High Range: 200-1000 µL Use large blue tips Digits from top to bottom represent: 1000’s 100’s 10’s The 1’s are indicated by the tiny white tick marks in the dial with the 10’s. Marks are in increments of 2 µL This pipette is set to 1000 µL

  12. This pipette is set to 990 µL