1 / 8

Monday 12.7

Monday 12.7. 03:00 Stable beams 9_6_6_6 09:40 back to ADJUST to switch on damper and switch off octupoles . 10:20 back to STABLE BEAMS. 11:57 beam dumped by LHC VELO when switching back to ADJUST mode after ADJUST handshake. VELO was not fully out.

stash
Télécharger la présentation

Monday 12.7

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Monday 12.7 • 03:00 Stable beams 9_6_6_6 • 09:40 back to ADJUST to switch on damper and switch off octupoles. • 10:20 back to STABLE BEAMS. • 11:57 beam dumped by LHC VELO when switching back to ADJUST mode after ADJUST handshake. VELO was not fully out. • End of a very good fill, luminosities still at 7E29. No problem with damper in stable beams. • 13:40 Access. • S12 QPS fixed. • FMCM threshold increase on RMSD.B1(2). Up by a factor ~ 4 at injection. Rough test with beam is OK (vertical shift of 3 mm on BTV in front of TDE). To be repeated with a complete OFF to the PC (injection). • RF access in P4. 8:30 meeting

  2. Tune spectra damper On-Off 8:30 meeting

  3. Monday 12.7 • 10:00-17:00 SPS multi-bunch cycle • Continued setting up of the cycle with 4 injections. Emittances below nominal. • Adjusted extraction kicker delays to extract ALL 4 bunches. • Extraction to upstream TEDs for both B1 and B2. • Extraction to TI2 downstream ok. • Everything looking ok – next step is injection into the LHC. • 15:00 LHCb with - polarity • 17:00 TDI P2 problem • Does not reach requested setting. Mechanical problem to be fixed today. • TDI in position with help of the piquet. • 17:30 Injection • Large orbit perturbation from LHCb polarity inversion – large local kick at MCBX.1R8. 8:30 meeting

  4. Monday 12.7 • 19:30: Filling 12_8_8_8 9E10/bunch • 20:00: Ramp • 20:45: Flat top • Incorporated RT trims from orbit into settings/functions. Worked partly only – anything changed in the past 2 weeks??? • When the OFB was switched off, the settings of the RT suddenly jumped to NaN for all vertical orbit correctors (????????), horizontal plane OK. • Switching ON/OFF OFB seemed to indicate that it was still working… • 21:20 Squeeze • Beam lost due to vertical orbit change: the OFB did not act in vertical. • Beam dumped by losses in IR7 (84 s RS on MQWA). • 23:00 Setup • MKI problem IR8 – faulty after pressure rise. • 00:30 Injection 8:30 meeting

  5. Tuesday 13.7 • 02:00: Again some issue get the OFB ON • 02:30: Ramp • 04:00: Squeeze • OFB off by itself while squeezing. Orbit change moderate and beam survived. Manual correction at 7 m, then OFB on again. • 05:20 Stable beams fill 1224 • L 1.4E30 cm-2s-1. • Some beam loss after ATLAS lumi scan. • Strong losses correlated with lines at 0.315 in Q spectrum. 8:30 meeting

  6. Fill 1224 8:30 meeting

  7. Tune spectrum lines… 8:30 meeting

  8. Tuesday 13.7 • Keep this fill for some time, try again damper. • Multi-bunch injection studies later today. • Fill overnight. • Check OFB issues during the day (start with offline checks). 8:30 meeting