Tackling Hard-to-treat homes

Tackling Hard-to-treat homes. Heat pumps, solid wall insulation and non-traditional construction. Energy Efficiency Partnership for Homes. Three research exercises commissioned by the Hard-to-treat homes sub-group: Solid Wall Insulation: Impetus, 2004 Heat Pumps: People for Places, 2005

tadeo
Télécharger la présentation

Tackling Hard-to-treat homes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tackling Hard-to-treat homes Heat pumps, solid wall insulation and non-traditional construction

  2. Energy Efficiency Partnership for Homes Three research exercises commissioned by the Hard-to-treat homes sub-group: • Solid Wall Insulation: Impetus, 2004 • Heat Pumps: People for Places, 2005 • Non-traditional construction: CSE, 2005

  3. Fuel poverty and non-traditional construction Ian Preston, CSE Dr Richard Moore

  4. Background • ~1 million non-traditional properties in UK • Majority built between 1945 the and early 1970s • Over 500 systems built between 1919 and 1976 • Termed system-built or pre-fabricated • Four broad categories, by wall construction • Thermal efficiency varies significantly • In practice, the majority of investment was designed to overcome defects

  5. Aims of study • Investigate how many non-traditionally constructed homes still exist in the UK • Identify the risk of fuel poverty within them • Identify examples of best practice and potential case study areas

  6. Methodology • Produce estimates of SAP and fuel poverty from all four national HCSfor 80 proprietary systems • Analysis by nation, sub-category, and where possible proprietary system • Results for Scotland and Wales are limited by the design and in the case of Wales by the quality of their HCS

  7. Methodology (cont.) • Estimates of NTH for each local authority • Compilation of database from a range of sources • Identified 52 authorities with high levels of NTH • Contacted the management body to establish works undertaken, and the associated changes in SAP or risk of FP

  8. Sample results Wall construction in England

  9. Non-masonry homes(x1000)

  10. SAP ratings by construction

  11. LA survey • 19 out of 52 authorities contacted responded • 18 respondents (95%) provided numbers of non-traditional houses (LA or LSVT) • 14 supplied details of the improvements made • 11 provided indicative figures for average work costs • Only 6 had estimates for changes in SAP ratings, • None commented on the effects of improvements on fuel poverty

  12. LA Survey • Significant levels of improvement works have been carried out on all non-traditional stock • Typical measures include; EWI or replacement brick cavity walls, LI, central heating and new kitchens and bathrooms • Majority of investment between 1980s and 90s, but there is a significant amount of ongoing maintenance and improvement • Estimated cost of works varies significantly, i.e. from £3,000 to £80,000

  13. LA survey • Cost of improvements and the value of property is a factor in an authority’s decision to improve them i.e. Rugby Borough Council • A comprehensive package of measures is required to a target SAP rating of 65 or above • An average cost of £10,000 provides a good indication of expenditure required per property* • Costs can be significantly higher when structural work is required to improve or replace walls

  14. Study of heat pumps for Hard-to-treat homes Nicholas Doyle, Places for people Alan Pither

  15. Aims • Report on application of heat pumps to hard-to-treat homes • Guidance to local authorities, architects and developers

  16. Outputs • Main heat pump technologies • Commercial providers • Applicability of the technology • Case studies • Application matrix • Initial guidance

  17. Methodology • Literature review • Database • Interviews with key people • Questionnaire 1: Companies • Questionnaire 2: Utilities • Questionnaire 3: Users

  18. Database • UK Heat Pump Network • Heat Pump Association • Ground Source Heat Pump Club • Clear Skies • Now most up to date Dbase

  19. Key interviews • Heat Pump Association • Manufacturers, Installers and Suppliers • Energy Companies • Landlords • Ground Source Heat Pump Club

  20. Findings • Supplier and installer • Member of HPN • Majority of Technology is G2W plus W2W • Operates throughout UK and occasionally outside • Market split evenly between HA, LA and individual householders • Majority of work in newbuild • Definitely doesn’t believe that HP can be used in HTT - one exception

  21. Findings • Cautious • Overloaded with research • Industry changing fast • A tipping point?

  22. Utilities survey • All EEC managers called • Only 2 responses • Cautious – commercially sensitive • Special tariffs not perceived as necessary • Funding under EEC 2?

  23. Residents’ survey • Prize Draw • Technology ‘Blind’ • Perception of heating and hot water • Penwith HA, Westlea HA, SCHRI • Not Clear Skies

  24. Residents’ survey • Majority had positive views with notable exceptions • Controls understood • Split between those who thought they were clear and those who thought ‘could be clearer’ • Costs • Limited time with systems • Average per week - £13 but ranged from £9 -£20 • Majority thought very reasonable or affordable

  25. Types of heat pump • Ground to water • Ground to air • Water to water • Water to air • Air to water • Air to air

  26. Types of operation

  27. Types of system • Ground (or water) source heat pump systems using closed loop water source heat pumps. • Ground (or water) source heat pump systems using open loop water source heat pumps. • Ground source heat pump systems using DX heat pumps. • Air source heat pump systems

  28. Case studies 1 Penwith Housing Association, Ludgvan 2 Westlea Housing Association, Withy Close 3 Fife Special Housing Association, Ochil View, 4 Shettleston Housing Association, Glenalmond Street, Shettleston 5 Geothermal Heating and Cooling, Burton On Trent 6 Geothermal Heating and Cooling, Kidderminster 7 West Lothian Council

  29. Key lessons • Costs dependent on local geological/site conditions • Ground water levels • Need for lining of boreholes • Bore both supply and return boreholes at the same time and an early stage in the project to monitor flows • Lack of a user manual

  30. Key lessons • Need to explain to occupants that their radiators will not be hot to touch • Correct programming and setting of heat pump temperatures to ensure efficient running of the system is vital • Ensure that the best electricity tariff is used • Need to train maintenance contractors

  31. The solution for hard-to-treat homes? • High specific heat loss (> 100 W/m2) so require relatively large heating systems. • If the CoP is >3, they will provide cheaper fuel running costs than any other type of heating system (at current tariff levels). • The issue is whether the capital cost is cost-effective compared to the alternatives: • The capital cost of ground source heat pump systems is relatively proportional to the output required.

  32. The solution? • Running costs of heat pumps may be lower but not low enough for as an alternative to improved insulation. • Low maintenance costs: £120-£250 per year saving (compared with gas systems?)

  33. Factors • Access to mains gas. • Whether the property can be reasonably well insulated using cost effective insulation measures such as cavity wall insulation and loft insulation. • Whether the property is to be comprehensively refurbished, including internal or external wall insulation and floor replacement.

  34. Factors • The existing heating system in the property. • Sufficient space for the installation and adequate means of access for the installation equipment. • Other local factors that could affect the cost, e.g. ground water levels, the capacity of the local electricity network.

  35. The Matrix

  36. Conclusions • Newbuild is the natural market • A significant industry is developing • Existing housing will require individual assessment • Not an alternative to insulation for HTT, but complementary to it

  37. Conclusions - suitability? • Ground source heat pumps for insulated houses off mains gas • Air source heat pumps for high rise/mid rise flats • Combination with small-scale renewables, e.g. wind/PV, but even higher capital costs

  38. Insulating solid walls: a challenge for local authorities and housing associations Dave Barton, Impetus Alastair Brooks, Impetus

  39. Solid wall insulation research Aims: • To produce impartial, practical and user-friendly reports • To help policy community, local authorities and housing associations

  40. Objectives To investigate: • experience of specifying, installation and ‘usage’; • range of costs and • perceived performance of the technology.

  41. Cost-effectiveness

  42. Why solid wall insulation? • More cost-effective than some measures currently promoted • Significant energy savings • A body of experience in social housing • Sound technical guidance • Need to disseminate existing practice and instil confidence

  43. Methodology • Desktop research • Telephone interviews with key players • Focus group of experience in: • social housing and • promoting to the private sector • Identify case studies • Householders’ feedback

  44. General findings • Building improvement measure, not purely thermal improvements, particularly for EWI • Opportunity measure, needs long-term planning: not simple retrofit • Considerable associated costs and disruption • Technical detailing and quality installations are essential

  45. Comparison of IWI and EWI • More experience on EWI • EWI adds value • EWI extends building life • EWI better able to deal with cold bridging • EWI: systems approach, installers and warranty • Overall comparison table in report

  46. Costs • Variable dependent upon building type, numbers etc • £2000 for IWI is not unusual • Typically EWI £5000 to £10000 for EWI • Up to £25,000 for a new brick skin and cavity wall

  47. Findings: social housing • Generally good feedback from tenants on EWI • Issues with mixed tenure on blocks • Integrate EWI with glazing programme • IWI dependent upon skilled builders • Some concern about robustness of dry-lining in social housing • No detailed research found on householders feedback

  48. Findings:private sector • A few small-scale schemes • Limited take-up • Grants of £1000 to £3000, some interest free loans • Usually marketed with other measures

  49. Social housing exemplars • Mid-Suffolk District council: post-1919 terrace improvements • London Borough of Enfield: improvements to high-rise blocks • Sandwell Borough Council: an example of a new brick skin and cavity wall • Sheffield City Council: non-traditional low-rise housing

  50. Private housing scheme exemplars • Leicester City Council: Realise • The Oxford Solar Initiative • Stroud District Council’s Energy Efficiency Grants • Wyre Borough Council: Wyred for Energy