1 / 11

Global Rapid Diagnostic Leader SD

Global Rapid Diagnostic Leader SD. General Information. HIV-1 positive. 1 drop of blood (Simple). Wait in 1~5 Min. (Fast). Interpret the result visually (Accurate). HIV-2 positive. Rapid Test ?.

tbuswell
Télécharger la présentation

Global Rapid Diagnostic Leader SD

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Global Rapid Diagnostic Leader SD

  2. General Information HIV-1 positive 1 drop of blood (Simple) Wait in 1~5 Min. (Fast) Interpret the result visually (Accurate) HIV-2 positive Rapid Test ? Everybody can detect all of HIV-1 and HIV-2 with only 1 drop of blood in Everywhere, Every time

  3. SD BIOLINE HIV-1/2 3.0 Test • Immunochromatographic Test for the antibodies of all isotype (IgG, IgM, IgA) • specific to HIV-1 including subtype O and HIV-2 • The 3rd Generation Method (Direct Sandwich Method, Ag-Ab-Ag) • Serum/Plasma/Whole Blood specimens are avaiable • HIV-1 Subtype “O” Detectable • IgM Detectable : Early HIV1/2 detectable • Sensitivity : 100% • Specificity : 99.8% • Using Capture Antigen : HIV-1 (p24, gp41), HIV-2 (gp36)Ag • Approved by KFDA • Evaluated by WHO • Participation of WHO Tender

  4. Quality Data Evaluation 1. Performed by Pasteur Institute France • 65 seroconversion panels tested with SD and compared to Abbott Determine HIV1 • Number of missed samples compared to the potential best test • Result : The HIV 1 sensitivity level of SD HIV1/2 Rapid test is superior to Abbott • Determine HIV 1.

  5. I.D Number ---U.S. FDA-Licensed Anti-HIV EIA Test result--- SD BIOLINE HIV1/2 3.0 Abbott HIV-1/2 S/co Gen.Sys HIV S/co Gen.Sys. HIV-1/2 S/co Org.Tek HIV S/co PRB959-01 Negative 0.1 0.1 0.1 0.3 PRB959-02 Negative 0.3 (Negative) 0.1 (Negative) 0.1 (Negative) 0.4 (Negative) PRB959-03 Positive 1.7 (Positive) 0.1 (Negative) 0.2 (Negative) 0.4 (Negative) PRB959-04 Positive 16.6 (Positive) 1.6 (Positive) 1.8 (Positive) 1.8 (Positive) PRB959-05 Positive 9.1 3.0 7.3 4.2 PRB959-06 Positive 8.6 3.2 7.6 4.7 PRB959-07 Positive 8.5 3.4 7.8 5.3 Quality Data Evaluation 2. Performed by Pasteur Institute with HIV-1 Seroconversion Panel BBI(PRB959) • This evaluation shows the result that SD BIOLINE HIV1/2 3.0 Test can detect antibody for • HIV type-1 earlier than some U.S. FDA-Licensed Anti-HIV EIA Kits

  6. Quality Data Evaluation 3. Performed by National AIDS RESEARCH INSTITUE in India (1) Panels of sera tested : total 90 sera including 45 confirmed anti-HIV positive and 45 confirmed anti-HIV negative sera by INNO-LIA HIV confirmation(Innogenetics) (2) Evaluation Result - Sensitivity : 100% - Specificity : 100% Evaluation 4. Performed by Christian Medical College and Hospital in India (1) Panels of sera tested : total 100 sera including 25 confirmed anti-HIV positive and 75 confirmed anti-HIV negative sera by PCR (2) Evaluation Result - Sensitivity : 100% - Specificity : 100%

  7. Quality Data Evaluation 5. Performed by National AIDS REFERENCE LABORATORY in Malaysia • Panels of sera tested : total 100 sera including 50 confirmed anti-HIV type-1 positive and 50 confirmed anti-HIV type-1 negative sera • Evaluation Result • - Sensitivity : 100% • - Specificity : 100%

  8. Quality Data Evaluation 6. Internal evaluation with clinical sera A. Evaluation Result with 30 sera of anti-HIV-1 positive B. Evaluation Result with 25 sera of anti-HIV-2 positive C. Evaluation Result with 502 sera of anti-HIV-1/2 negative • The result shows that the the accuracy of SD BIOLINE HIV 1/2 is equal to other commercial • ELISA kits.

  9. Quality Data Evaluation 7. WHO evaluation (phase1) of HIV1/2 Rapid test 1. Result Table • Result • Sensitivity 100% • HIV-1 : 100% • HIV-2 : 100% • Specificity 99.3% • Seroconversion panel : Similar result Behring ELISA

  10. Quality Data • This evaluation shows the result that SD BIOLINE HIV1/2 3.0 Test • can detect antibody for HIV earlier than other commercial HIV1/2 • Rapid test kits

  11. Quality Data

More Related