1 / 10

nd280/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO

http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ Meeting on 2008/03/20-21 MPPC test bench at KYOTO. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO. X bez światła.

tehya
Télécharger la présentation

nd280/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ Meeting on 2008/03/20-21 MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  2. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  3. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  4. testy MPPC w KYOTO i u Francuzów

  5. X bez światła testy MPPC w KYOTO i u Francuzów ze światłem

  6. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  7. 250C http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  8. What information will we need in future (construction, operation) from test bench? • • We will save all raw data and check all measurements, but it will be too much to • handle for later use • • Construction needs: • • to reject ‘bad’ ones (screening) • • to sort devices (e.g. by Vbd) • • Operation needs: • • Calibration will be done in situ, anyway • • Still we need ‘firm’ reference point • • I propose following to start discussion Your inputs are really welcome • Serial ID (TA0001, TB0001, ....) • • Breakdown voltage and gain slope for 3 temps • • Noise rate (>1pe) at a fixed ΔV (for 3 temp) • • PDE at a fixed ΔV (expect no temp/device dependence) • • Cross-talk + afterpulse at a fixed ΔV (expect no temp/device dep.) • • Hamamatsu test data • • Any note during measurement(?) • Do we need more points? http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ MPPC test bench at KYOTO testy MPPC w KYOTO i u Francuzów

  9. Where do we find those information with new packaging ? • What do we have to measure ? • Reverse current vs Vop & T° (Vbr+ΔV) • Gain vs Vop & T° • Dark Noise Rate vs Vop & T° • Photo detection efficiency P.D.E. (relative to PMT) Measured Gain 7.67E+05 To be compared with value on MPPC bag M=7.50E+05 Dark Noise Rate350 KHz value on MPPC Bag : 378 kHz (~0.5pe) Optical Crosstalk : 25 kHzvalue on MPPC Bag : 25 kHz(~1.5pe) http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ Meeting on 2008/03/20-21 MPPC test bench at LAL testy MPPC w KYOTO i u Francuzów

  10. Information in databasePropozycja Francuzów KYOTO • MPPC ID • Kyoto / LLR • Hamamatsu data • gain, • Vop, • Noise 0.5 p.e., • Noise 1.5 p.e. • Vbd, Slope @15, 20, 25 °C • Noise rate @0.5 p.e. 15, 20, 250CDV = 1.4 V • PDE DV = 1.4 V @ 20 °C • Cross-talkDV = 1.4 V @ 20 °C • After-pulse DV = 1.4 V @ 20 °C • Czy nie chcą mierzyć Noise Rate @ 1.5pe?? • Serial ID (TA0001, TB0001, ....) • • Breakdown voltage and gain slope for 3 temps • • Noise rate (>1pe) at a fixed ΔV (for 3 temp) • • PDE at a fixed ΔV (expect no temp/device dependence) • • Cross-talk + afterpulse at a fixed ΔV (expect no temp/device dep.) • Hamamatsu test data • Any note during measurement(?) Proponują zapisanie w Data Base takiej samej informacji. Pewnie trzeba by się dostosować. http://www.nd280.org/ngrid/Meetings/ingridmeetingllr/ Meeting on 2008/03/20-21 Porównanie: MPPC Test Bench at LAL and Test Bench at Kyoto testy MPPC w KYOTO i u Francuzów

More Related