A NEW generation ELI 280 for Medica….

November 2011. A NEW generation ELI 280 for Medica…. ElI 280 features at a glance. Larger Color 10.1 inch LCD Touch Screen New front ends Full disclosure Improved Automatic Interpretation A more up-to-date User Interface Easier upgrade capability. The NEW ELI 280….

tevy
Télécharger la présentation

A NEW generation ELI 280 for Medica….

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. November 2011 A NEW generation ELI 280 for Medica….

  2. ElI 280 features at a glance • Larger Color 10.1 inch LCD • Touch Screen • New front ends • Full disclosure • Improved Automatic Interpretation • A more up-to-date User Interface • Easier upgrade capability

  3. The NEW ELI 280…. Completely newly redesigned Housing, with the NEW Mortara Colors and look New 10.1” touch screen Super-bright 10.1” Color LCD Completely redesigned Electronics, with a faster processor

  4. The NEW ELI 280…. AM 12 MODEM WLAN Power USB D USB LAN

  5. The NEW ELI 280…. • WAM - Wireless patient Cable • For superior versatility and ease of use, a digital front end that guarantees less noise and data quality • UNIQUE in the Industry!!!! • Unsurpassed 40 KHz sampling rate • Frequency response 0.05 to 300 Hz • The best in class for adults and pediatric ECG acquisition. • Remote control keys for easy and fast ECG acquisition or Rhythm printout. • Lead Fail indication • AM 12 available asoptional configuration

  6. Algorithms: features and benefits…. • VERITAS 7 Resting Interpretation Algorithm • Mortara Algorithm for Adult and Pediatric interpretation, from 0 days of age • VERITAS in its latest revision, introduces several improvements, a better P-wave detection, enhanced Pacemaker analysis • Added STEMI message (*** ACUTE MI ***) statement

  7. Algorithms: features and benefits…. • BEST 10 • Acquiring an ECG on non-cooperating patients is a challenge. BEST 10 has been thought to help speeding up this process. The ELI 280 incorporates a buffer that is used by the BEST 10 to find the best and noise free 10 seconds of ECG data. Perfect on pediatric patients, it helps saving time in the daily routine. Unique in this class of cardiographs!

  8. Algorithms: features and benefits…. • Lead Reversal • Lead placement is becoming a serious issue, important to the point that it can lead to misdiagnosis: the technician may not realize the issue, the ECG is sent to the Cardiologist and the record may be read improperly. • In some facilities more than 5% of all acquired ECGs are affected by lead reversal. • v7 implements real time indication of lead reversal • Real time detection and indication to user of possible limb lead swap • Real time detection and indication to user of possible precordial lead (sequential V leads) swap… • Saves time and reduces error in ECG acquisition

  9. Communication: features and benefits…. • USB direct connect • RS 232 ports disappeared from PCs and a more modern direct connectivity allows an easier integration with today’s PCs and Operating Systems • Simply connect the ELI x50c to a PC and drag and drop records into ELI LINK • Transmission to USB Memory stick • An alternative way for users that do now want to use the cable • Plug a memory stick in the Host USB port and SYNC the unit: records will be “transmitted” to the memory stick. • PDF generated via ELI LINK 3.10 or later • The USB transmission or file transfer can be perfectly integrated with the ELI LINK. • With ELI LINK and its import folder, the user can generate PDF files (and other formats) automatically

  10. Communication: features and benefits…. • LAN • Today’s most common communication method • Support 10/100 Mbps • Faster and more reliable integrated chipset • WLAN • New module, with support for the most common encryption standards (WEP, WPA, WAP2, LEAP/PEAP) • WLANandLAN • Hardware Now available simultaneously on the same unit • WLAN is very nice and easy but coverage could be a problem, IT likes the idea of a single configuration to deal with. • LAN is a perfect backup when WLAN does not offer perfect coverage.

  11. Communication: features and benefits…. • Time Sync • The ELI 280 allows time synchronization: a great tool to make sure all the cardiographs are time-synchronized with the Hospital network. No need to manually change time at DST! • Syncs with ELI LINK 3.10

  12. Some more key features and benefits…. • 12-Lead Preview • Thanks to the bright and sharp LCD, allows the preview of what will be printed (the option for 8-lead preview is still available) • ECG Storage • Internal memory allows a complete day of work • Basic configuration = 100 records • Expanded memory option = 200 Records • USB to Memory Stick • Included in the basic configuration !! • 2D Bar Code reader • Now available for the ELI 280