1 / 7

Cryogenic test stand and Coupler cooling pressure

Cryogenic test stand and Coupler cooling pressure. Bertrand RENARD CEA. ESS Cryomodule status meeting 2013 January 09 Lund. CRYOMODULE TEST STAND. Existing cold box, Dewar and pumping line (red) New Dewar, valve box and pumping line in common for ESS (2 K) and Ifmif (4.5 K) (blue).

tfrizzell
Télécharger la présentation

Cryogenic test stand and Coupler cooling pressure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cryogenic test stand and Coupler cooling pressure Bertrand RENARD CEA ESS Cryomodule status meeting 2013 January 09 Lund

  2. CRYOMODULE TEST STAND • Existing cold box, Dewar and pumping line (red) • New Dewar, valve box and pumping line in common for ESS (2 K) and Ifmif (4.5 K) (blue) page

  3. Dewar Valve Box > 1,2 m CRYOMODULE TEST STAND

  4. CRYOMODULE TEST STAND • Cryogenicequipmentforeseen LHe Transfer line (instead of SHe) LN2 Transfer line (instead of 50 K He) Dewar with LHe PhS Valve box with LN2 PhS and 2 K heatexchanger VLP Return line Electricalheater for VLP line Control valves and instrumentation • Information required Cryomodule geometry Cryomodule interfaces Choice of 2 K heatexchanger position page

  5. COUPLER COOLING PRESSURE • Inlet circuit at 3 bar Inlet valve more simple if circuit canbefedwith 3 bars. • Safetyrules High pressure He alreadypresentinside Cryomodule thermal shields. • Circulation More pressure availableis best for He circulation, but regulation valve has to takeintoaccount max inlet pressure. No more risk of LHe presenceat coupler inlet. page

  6. COUPLER COOLING PRESSURE z • Pressure safetypreliminarycalculation Von Mises stress frommostunfavorablecalculation shows 16 MPa for thin 1 mm external tube, with a yield stress of 200 MPa. 1 order of magnitude mechanicalmargin CEA approves 3 bar for nominal pressure inox 1 mm diam 100 mm Pression 3 bars page

  7. Merci ! Bertrand RENARD CEA ESS Cryomodule status meeting 2013 January 09 Lund