NSLS-II Insertion Devices

NSLS-II Insertion Devices. Toshi Tanabe George Rakowsky, John Skaritka, Steve Hulbert, Susila Ramamoothy NSLS/BNL NSLS-II Accelerator Systems Advisory Committee 2006/10/9-11. Outline. List of NSLS-II insertion devices (baseline + options) Comment on Phase Errors

tillie
Télécharger la présentation

NSLS-II Insertion Devices

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NSLS-II Insertion Devices Toshi Tanabe George Rakowsky, John Skaritka, Steve Hulbert, Susila Ramamoothy NSLS/BNL NSLS-II Accelerator Systems Advisory Committee 2006/10/9-11

  2. Outline • List of NSLS-II insertion devices (baseline + options) • Comment on Phase Errors • Cryo-Permanent Magnet Undulator (CPMU) for hard X-rays • Cold Measurement Issues • New magnet and pole materials • Elliptically Polarized Undulator (EPU) • Apple-II v.s. HiSOR (SPring-8) Design • Permanent Magnet Damping Wiggler • Superconducting Wiggler (SCW) • Superconducting Undulator (SCU) • Conventional, VPU and HTS versions • No QPU, Figure-8, Revolver options are discussed

  3. List of NSLS-II IDs

  4. RMS Phase Errors • Improving the rms phase error from 3.0° to 2.0° changes the relative intensities by 86% -> 98% for harmonic 7 (D = 12% points), 81% -> 96% for harmonic 9 (D = 15% points), and 75% -> 93% for harmonic 11 (D = 18% points). Roger Dejus

  5. CPMU • Cryo-Permanent Magnet Undulator (Hara, et. al., 2004) • Simple Concept: NdFeB has a negative thermal coefficient of remanent field (Br) [-0.1 % / K@20ºC], and of intrinsic coercivity (Hcj) [-0.5% / K@20ºC ] • Higher field and higher radiation damage resistance simply by cooling the magnet array in lower temperature (~150K) • Remaining Issues • Cold measurement system • Cold shimming technique if required • New Material R&D • PrFeB magnet and Dy pole combination for operation at lower temperature than 150K

  6. History of Mini-Gap Undulators at the NSLS Currently Installed Proposed

  7. X-25 MGU Installed in the NSLS X-Ray Ring

  8. Direct Gap Measurement by Keyence LS-7030 Measurement accuracy of ±2mm and repeatability of ±0.15mm Upper Array Detector Emitter Lower Array

  9. Direct Gap Measurement at Micron Resolutions Keyence gap readings track with post temperatures 35C° 10 min Upstream Gap 10 mm Post temperatures Downstream Gap 30C°

  10. Cold Measurement System Cold In-Situ Field Measurement In-vacuum mapper with Hall probe. The postion accuracy is maintained by laser tracker and piezo controller. • In-vacuum streched / pulsed wire systems are also in consideration

  11. EPUs • Apple-II v.s. HiSOR EPU (eventually in-vacuum) • Apple-II : bigger tuning range, simpler structure • HiSOR EPU: easier shimming and more benign field profile • Better vacuum chamber design to reduce the radiation damage of permanent magnets maybe needed

  12. Peak Field Profile Comparison • HiSOR • Apple-II Tracking studies are needed to determine the effect of dynamic aperture reduction due to these roll-offs.

  13. MPW (1.8T / 15mm Gap) • Conventional Hybrid Design with Permendur Poles • Close to the limit with simple block structures • Reducing the gap with soft-iron poles will certainly reduce the cost

  14. Superconducting Wiggler • NSLS-I Three Mode SCW by Oxford • 11 pole @ 3.0T (lu=17.6cm, gvac=19.5mm) • 5 pole @ 4.7T • 1 pole @ 5.5T • HTS version will be investigated

  15. Superconducting Undulator (NSLS proto type) Bifilar SC winding APC-type NbTi with integral He gas cooling @ 4K • APC-type NbTi expected to run at Je=2000A/mm2 • Cooling channel underneath the coils to ensure maximum cooling (Ceramic) isolating spacer Beam tube with integral cooling by He gas > 4K Low carbon steel yoke Yoke: 1006 Steel Embedded He Gas Cooling Channel

  16. Other Insertion Device R&Ds • New (In-vacuum) Gap Separation Mechanism • Superconducting EPU • High-Temperature Superconducting Undulator • Cryocooler capacity increases drastically with higher temperature (ex. 300W@40K, 600W@77K by Cryomech, Inc.) • Splices do not create quench problem if cooled sufficiently • Quench propagation is on order of magnitude slower than LTS  Simpler and cheaper protection scheme Innercage S. Chouhan

  17. Summary • CPMU • Cold measurement and shimming are main remaining issues • New material R&Ds for further enhancement of the performance • SCW • OK for LTS • Higher field version / HTS version will be investigated • EPU • Apple-II or other structure to be determined after tracking study • Better vacuum chamber design to minimize radiation damage on magnets • In-vacuum EPU design will be a R&D subject • DW • Design and cost issues only • Possible candidate for new gap separation mechanism • SCU • Low temperature SCUs still require R&Ds • HTS versions are promising candidates in the future