1 / 25

ENERGY METERS DME SERIES

ENERGY METERS DME SERIES. ENERGY METERS DME SERIES. Expandability with EXM modules. High measurement currents in small housing. Multi-measurement. Digital display with white backlight. MID approved version. Built-in RS485 version. THE LOVATO ELECTRIC SOLUTION.

tynes
Télécharger la présentation

ENERGY METERS DME SERIES

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ENERGY METERS DME SERIES

  2. ENERGY METERS DME SERIES Expandability with EXM modules High measurement currents in small housing Multi-measurement Digital display with white backlight MID approvedversion Built-in RS485version THE LOVATO ELECTRIC SOLUTION In a market scenario where the energy consumption must be controlled and managed in an efficient way, Lovato Electric has a new energy meters series.

  3. ENERGY METERS DME SERIES

  4. ENERGY METERS DME SERIES EXM for DME D130: EXM1000, EXM1001, EXM1002 (digital I/O) with 2 limit thresholds on kW by defaultCompatibility with EXM1010 (USB), EXM1011 (RS232), EXM1012 (RS485), EXM1013 (ethernet) under technical investigation

  5. ENERGY METERS DME SERIES

  6. ENERGY METERS DME SERIES

  7. ENERGY METERS DME SERIES ACTIVE ENERGY MEASUREMENT – DIRECTIVE 2004/22/EC (MID) • Energy meters are mainly intended to measure energy for billing purposes • In European Union, every measuring instrument for billing must comply with and be certified according to MID (Measuring Instruments Directive) The energy meter is designed to be safe and accurate(Type tests). MID warrants The energy meter is produced to be safe and accurate (Production conformity ). All DMED energy meters are available in a version with MID approval. “MID” suffix at the end of order codes.

  8. ENERGY METERS DME SERIES ACTIVE ENERGY MEASUREMENT – ACCURACY MID and non-MID active energy meters comply with different standards: • Non-MID: IEC/EN 62053-21 • MID: EN 50470-3. A complete correspondence between the two standards does not exist.

  9. ENERGY METERS DME SERIES GENERAL FEATURES Metrological LED DMED series is equipped with a metrological LEDto indicate the energy consumption Multifunction key • Partial counters cleraing • Measurement browsing • Programming. Sealable terminal coversare standard-supplied.

  10. ENERGY METERS DME SERIES Overtaking of a limit thresholdon a controlled measurement Pulses for active energy (kWh) or reactive energy (kvarh) counting. STATIC OUTPUT The static outputs can be: • Pulses for active energy counting (kWh) • User programmable in order to get: Automatic reset. After K pulses, 1 kWh is counted (accumulated).

  11. ENERGY METERS DME SERIES STATIC OUTPUT PROGRAMMED AS LIMIT THRESHOLD 50mA at 24VDC The overtaking of the limit threshold enables a buzzer to advise the user about a power shutdown. 8LP 2T ZGB Adding a timer, the static output can enable the buzzer and a timer that, after the programmed delay, opens a non-priority load. TM M2 The information is transmitted to a programmable relay to: • Display a message. • Enable a buzzer. • Enable timers to open non-priority loads. • Let the user choose which load should be disconnected using the front panel keys. KINCO

  12. ENERGY METERS DME SERIES DME D310 T2 3 x EXM… DME D130 - DME D310 T2EXPANDABILITY • DME D310 T2 includes more functions when the expansion EXM… modulesare installed: • EXM1000/EXM1001 (Inputs/Outputs) • EXM1010 (USB) • EXM1011 (RS232) • EXM1012 (RS485) • EXM1013 (Ethernet) • EXM1020 (RS485 + 2 relay outputs) • EXM1030 (Memory).

  13. ENERGY METERS DME SERIES BUILT-IN COMMUNICATION PORT DME D121 and DME D320 are equipped with built-in RS485 port, compatible with Synergy RS 485

  14. ENERGY METERS DME SERIES DME CD – DATA CONCENTRATOR The data concentrator DME CD connects devices with no communication port but with at least one pulse output (i.e. DME energy meters) to a network. 3 x EXM1000/EXM1001to get up to 14 pulse inputs Built-in RS485 DME CD has: • RS485 port • 8 inputs available • Expandability with EXM… modules. 2 x EXM1000/EXM1001 to get up to 12 pulse inputs+ 1 x EXM1013 for Ethernet communication Built-in RS485

  15. ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR General counters (16) Settings: • Enabling • page description (16 character free text) • Units description (6 character free text) • Count UP source • Count DOWN source • Reset source (total and partial) • Count up source weight (multiplier/divider) • Count up source weight (multiplier/divider).

  16. ENERGY METERS DME SERIES 16 general counters DME CD - DATA CONCENTRATOR 16derivative variables (average) 16trend graphs Settings: • Enabling • Derivative calculation time • Units description (6 characters) • Derivative coefficient (multiplier/divider). 16mathematicalvariables Available operations with counters: • Sum, subtraction, multiplication, division • Arithmetics with a constant value Mathematics can be operands as well page description (16 character free text), units description (6 character free text).

  17. ENERGY METERS DME SERIES 16 general counters DME CD - DATA CONCENTRATOR 164-tariff pages 16derivative variables(average) Limit thresholds 16mathematicalvariables Pulses

  18. ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Some advanced functions come from DMGs: • Hour counter (with limit thresholds) • Boolean logic operations • Remote variables • Alarms • Programmable inputs and outputs.

  19. ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 1: Collecting data and alarms in a marina DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMECD RS485 IN1…8 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 Each station has: - DMED (1 or 3 ph) with pulse output - Low power alarm - Power supply enabling. DMECD RS485 IN1…8 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 EXM1013 Ethernet PC, internet, VPN, … DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN

  20. ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 1: Collecting data and alarms in a marina DMKSW software can read: • Energy meters • Average power values (derivative) • Energy cost (mathematics) • Alarms • Enabling commands.

  21. ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 2: Collecting data and alarms in a bottle filling machine DMECD Energy pulses DMED300T2 : 1 counter to store the energy consumption 1 mathematics to calculate the energy consumption every 100 bottles(kWh/100 bottles) Count-up source 1 counter to count up and down the bottles 1 derivative variable to calculate the production rate (bottles/minute) Quality control Bottles passage photocell Count-down source Rejected

  22. ENERGY METERS DME SERIES SWITCH Ethernet Wi-Fi INTERNET VPN EXP1013 EXP1012 8 + 4 max with EXM10... Ethernet DMG 800-900 DMG 300+EXM1013 DMG 800-900+EXP1013 DME CD data concentrator +EXM1013 Energy meters with pulseoutput DME .. T1 Ethernet 8 + 6 max with EXM10… RS485 ETH-RS485 RS485 RS485 DMG 210 DMG 300+EXM1012 DMG 700-800-900+EXP1012 DMK … DME CD (Data concentrator)

  23. ENERGY METERS DME SERIES SHOPPING CENTRE APPLICATION Ethernet Energy cost monitoring and allocationPower factor monitoring

  24. ENERGY METERS DME SERIES DME CD PV1 • DME CD expecially programmed forphotovoltaic application: • Absorbed energy counter input (1000 p/kWh) • Generated energy counter input (1000 p/kWh) • Mathematical exchanged energy counter • Self-consuming estimator (power and energy) • Autonomy from Utility estimator • 2 outputs to disconnect non priority loads • 1 input for alarms from inverters • DME CD KIT PV1 100 = DME CD PV1 + 2 x DME D110T1 Built-in RS485

  25. ENERGY METERS DME SERIES Thanksforyourattention! • www.LovatoElectric.com

More Related