1 / 28

Past Dam Failures with Modes of Failure

Past Dam Failures with Modes of Failure. Keith Mills, P.E., G.E. Acting State Engineer Oregon Water Resources Dept. 2014 NWHA Annual Meeting. Objective – Discuss major dam incidents relevant to the PNW. Four Dams were selected because Severe or potential severe consequences

ursala
Télécharger la présentation

Past Dam Failures with Modes of Failure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Past Dam Failures with Modes of Failure Keith Mills, P.E., G.E. Acting State Engineer Oregon Water Resources Dept. 2014 NWHA Annual Meeting

  2. Objective – Discuss major dam incidents relevant to the PNW • Four Dams were selected because • Severe or potential severe consequences • Modes of failure applicable to Pacific Northwest • Reasonable knowledge of incident cause

  3. Relevant Dam Incidents Vaiont1963 Northern Italy Teton1976 Eastern Idaho Taum Sauk2005 Missouri Kaloko2006 Kauai, Hawaii

  4. Lessons Learned • Comprehending geology - conditions • Design - state of the practice? • Construction practices • Non-engineered alterations • Operations, monitoring and Inspections

  5. Two Historical Failures • Johnstown (South Fork) 1889 • Saint Francis 1928

  6. South Fork Dam Type: Embankment (earth and puddle) 10 miles SE Johnstown, PA Constructed: 1840 - 1853 Height 72 feet Storage 15,000 acre-ft Date of Failure: May 31, 1889 Lives Lost: 2,209

  7. South Fork Dam

  8. Saint Francis Dam Type: Concrete Gravity Location: 70 miles North Los Angeles Constructed: 1924 to 1926 Height 205 feet Storage 38,000 acre feet Date of Failure: March 12, 1928 Lives Lost: 450+

  9. Saint Francis Dam Remnants after near instantaneous dam failure

  10. Vaiont Dam Type: Concrete thin arch Location: 60 miles North of Venice Constructed: 1958 -1960 Hydroelectric Height 869 feet Storage 122,000 acre ft Date of Failure: October 9, 1963 Lives Lost: 2,500

  11. Vaiont Dam Before After – landslide dwarfs dam

  12. Vaiont Dam mode of flooding DAM DID NOT FAIL DESPITE OVERTOPPING BY 200 + FT Gigantic landslide displaced reservoir Contributing Factors • Missed existing inactive landslide(s) • Control by changing reservoir levels • Extreme landslide size and speed (very rare) Note reservoir level and rate of movement

  13. Vaiont Dam –Lessons Learned • Comprehend the dam site geology • Unwise to rely on reservoir level to control landslide movement • Arch dams can be very stable (dam survived) • No timely independent investigation • Italian state - “the price of modernization”

  14. Teton Dam Type: Zoned Embankment 40 miles NE Idaho Falls Constructed: 1972 - 1976 Height 305 feet Storage 288, 250 acre feet Date of Failure: June 5, 1976 Lives Lost: 11 (middle of reported range) Property damage: $400,000,000 -$1,000,000,000

  15. Teton Dam Picture taken at near maximum breach just past noon, first observation of problems were that morning

  16. Teton Dam Mode of Failure • Primary:Development of rapid piping in right abutment with no defense or filter • Contributing Factors • Large open joints and fissures in next to key trench • Zone 1 (core) material highly prone to erosion and piping • Non standard key trench in abutment • No soil filter in abutment key trenches • Grout curtain inconsistent

  17. Teton Dam Lessons Learned • Designers must understand the significance of open fractures and voids • Key trenches in the abutment can make the situation worse • A defensive design for all parts of the dam was essential Abutment Key Trench

  18. Teton Dam Lessons Learned • Incomplete grouting can be very unsafe • No compacted fill is ever homogenous • Internal erosion can be masked if rock fractured and open • Piping through erodible fill can develop to a dam breach very quickly • Cooperating agencies can complete an outstanding forensic investigation

  19. Taum Sauk Dam Type: Concrete faced rock-fill with a parapet wall, liner added 90 miles Southwest of Saint Louis, MO Constructed: 1960-1964 Failure: December 14, 2005 87 feet tall - 4600 acre feet Lives Lost: 0 (5 serious injuries)

  20. Taum Sauk Pumped storage reservoir Inundation in yellow Flood wave stored in lower reservoir Camp located in inundation area Little use in winter Casualties could have been much higher

  21. Taum Sauk Mode of Failure Overflow eroding rockfill Crest uneven from settlement Improperly placed sensors Unsafely programmed sensors No direct observation Differential settlement (fines) Irregular foundation material Improper liner placement No spillway

  22. Taum Sauk Lessons Learned • All dams need a spillway • Dams, even rock-fill, settle over time • Concrete faced dams prone to severe damage if there is settlement • Organizations need to care about safety • Largest FERC fine, at least to that point • Dam failures impact all dam owners

  23. Kaloko Dam Type: Embankment/hydraulic fill Location: 10 mi NW Kapaa Built 1890, Raised 1911 Height 40 feet Storage 1200 acre feet Failure: March 14, 2006 Lives Lost: 7 Property damage: Still in litigation Complex ownership pattern

  24. Kaloko Dam Inundation Area after dam breach

  25. Kaloko Dam Mode of Failure • Primary:Spillway filled by new dam owner, then extended overtopping • (filled by irrigation ditch) • Contributing Factors: • Crest uneven (2 feet) • Lack of maintenance; • Trees hid erosion • Incorrect inspectors The breach

  26. Kaloko Dam Lessons Learned • DO NOT FILL IN THE SPILLWAY!!!!!!! • Incorrect hazard ratings can have serious consequences (Low when it should have been HIGH) • A red flag when dam owners and ditch operators do not talk • Inspect dams that need to be inspected • The dam regulator must inspect & investigate Where was dam safety?

  27. Key Lessons from the 6 incidents • Spillways need to handle design inflows • Understand big picture geology (rock and soil) • Old design flaws are common • As-built is different than as designed • Small dams failures have consequences on owners of large dams

  28. Acknowledgements • Robert B. Jansen, USBOR Retired, author of Dams and Public Safety • J. David Rogers, Professor of Geological Engineering, Missouri University of Science and Technology • Dave Pelty, Durham University • Robert Godbey, Hawaii Special Deputy A.G.