Test of KFParticle with K 0 s. J. Bouchet. outline. Test KFParticle with a easier decay particle ctau(K0)~ 2cm TCFIT was already tested on K0s and Lambda and shown good results : http://drupal.star.bnl.gov/STAR/system/files/update_Lambda.pdf What we can know : KFParticle agree with TCFIT

urvi
Télécharger la présentation

Test of KFParticle with K 0 s

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Test of KFParticle with K0s J. Bouchet

  2. outline • Test KFParticle with a easier decay particle • ctau(K0)~ 2cm • TCFIT was already tested on K0s and Lambda and shown good results : • http://drupal.star.bnl.gov/STAR/system/files/update_Lambda.pdf • What we can know : • KFParticle agree with TCFIT • Joe has shown that TCFIT works for long decay • Files used : day 110 to 112 from ProductionMinBias (run7)

  3. cuts • static const Double_t pTCut = 0.5; // transverse momentum cut • static const Double_t mKpiMin = 0; // min mass of (Kpi) association • static const Double_t mKpiMax = 1; // max mass of (Kpi) association • static const Double_t DcaCut = 1; // single track DCA to PV • static const Int_t TpcCut = 20; // TPC hits fitted • static const Double_t TrackLengthCut = 40; // min value for dEdxTrackLength • static const Int_t SiCut = 2; // (SVT+SSD) hits fitted • static const Float_t SigmaPionCut = 3; // ndEdx for pion • static const Float_t SigmaKaonCut = 3; // ndEdx for kaon • static const Double_t EtaMin =-1.0; // min track pseudorapidity • static const Double_t EtaMax = 1.0; // max track pseudorapidity • static const Double_t zcut = 5; // zvertex cut • static const Double_t PrimZResCut = 0.02; // zvertex cut • static const Double_t sigmaTCut = 2.0; // ratio single track dca/sigmaDca • static const Double_t ProbKFCut = 0.05; // lower limit for the probability of KF particle • static const Int_t writeHisto = 0; // flag to write histos

  4. #of events • Nothing unusual • # of events after vertex position Z and vertex resolution position cut is ~80 kEvents

  5. KFDecayLength • Large background for |KFDecayLength|< 2cm • Similar to what gives the standard V0 finder

  6. Inv mass • No cut here • No inv. Mass is seen before any topological cuts

  7. Inv Mass |n|<2 |n|<2 KFDecay>0 |n|<2 KFDecay>1 |n|<2 KFDecay>1.5

  8. comments • As for the standard V0 finder, a cut on decay length remove background • For decay>1.5, almost no background and a clear peak appears

  9. Decay length significance L • L is defined as : • Decay length/error of decayLength • No other cuts than the |n |<2 for both pions daughters • positive contributions appear for L >40

  10. Applying a cut on L No cut L >40

  11. Summary - to check • Cut on decay length from KFParticle removes background • Similar to V0Finder and TCFIT • Cut on L seems high : • have to check the error on decay length (if not underestimated) • Could try the lambda decay to check if KFParticle finds a larger decay length according to the one from lambda(c ~ 7 cm)